I want to search for...

Permit #2013090324

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00130-0230
CONDITIONED SPACE: 2166 sqft
GARAGE: 418 sqft
OPENED PORCH (WITH ROOF) : 204 sqft
OPENED PORCH (WITH ROOF) : 155 sqft
Total Square Footage: 2943 sqft
Block: 00130
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: (386)254-5081
Location Address: 63 WESTGRILL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/04/2013
NOC: RECORDED
Applicant name: WAYNE LAWRENCE ADAMS
Owner: ADAMS HOMES OF NW FLORIDA INC

Address

3000 GULF BREEZE PKWY

GULF BREEZE, FL 32563

Lot: 0230
Contracted Stated Job Value: ¤147,150.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ADAMS HOMES OF NW FLORIDA INC
Status Location Address State License Number Phone Fax
INACTIVE

1101 Gulf Breeze Parkway Suite 229

Gulf Breeze, FL 32561

CBC043518 (Exp: 08/31/2014) (386)254-5081 (386)252-8284

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 01/31/2014 FINAL APPROVED DROCKWELL
FINAL APRON (AFTER POUR/DRIVEWAY) 01/31/2014 APPROVED GLALIMA
ROW FINAL 01/31/2014 APPROVED GLALIMA
U -UTILITY RESIDENTIAL FINAL 01/31/2014 FINAL APPROVED DSPENCER
FINAL SURVEY (OFFICE USE ONLY) 01/30/2014 APPROVED FREODICA
ELECTRIC - EARLY POWER 01/14/2014 APPROVED DROCKWELL
PRE-APRON (PRE-POUR/DRIVEWAY) 01/07/2014 APPROVED RGROSS
Note: READY TO POUR
GRAVITY SEWER TEST 12/18/2013 APPROVED RMARVEL
U - SEWER TIE IN 12/18/2013 APPROVED DSPENCER
INSULATION 12/11/2013 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION 12/10/2013 CANCELLED BY APPLICANT RMARVEL
LATH/BRICK/ WATER BARRIER 12/06/2013 APPROVED DROCKWELL
ALL ROUGH 12/06/2013 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/18/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
FOUND SURVEY APPROVED (OFFICE) 11/18/2013 APPROVED FREODICA
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/15/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 11/15/2013 3:06:13 PM NOT READY FOR INSPECTION. WORK IN PROGRESS.
WALL SHEATHING 11/08/2013 APPROVED RMARVEL
ELECTRIC TEMP POLE 11/05/2013 APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 11/5/2013 2:50:13 PM RELEASED POWER AT 2:24
ELECTRIC TEMP POLE 11/01/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 11/1/2013 2:48:30 PM BOTH LINE AND LOAD SIDE FOR POWER IS WIRED INTO THE LINE SIDE OF METER CAN. PROPERLY WIRE METER CAN SO NOT BYPASSING METER. WIRE TO MANUFACTURERS INSTRUCTION AND INTENDED USE. NEC 2008 110.3
ELECTRIC TEMP POLE 10/31/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 10/31/2013 2:55:19 PM UNABLE TO CHECK METER CAN. JEA LOCK ATTACHED.
MONOLITHIC SLAB 10/28/2013 APPROVED RMARVEL
PLUMBING 1ST ROUGH UNDERGROUND 10/25/2013 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/30/2014 01/30/2014
Note: Released By: FREODICA
SW1 HOLD 01/24/2014 01/24/2014
Note: Held By: FREODICA final 1. Provide surface drainage flow to show direction of water drainage. It appears that the water flow at the back of the house near the porch is toward the foundation and it does not comply with 2010 FBCR 401.3.
ELEC COMPLETE 12/05/2013 12/05/2013
ZON COMPLETE 11/18/2013 11/18/2013
Note: Released By: FREODICA foundation survey
SW1 COMPLETE 11/15/2013 11/18/2013
Note: Released By: FREODICA foundation survey
PLUM COMPLETE 10/25/2013 10/25/2013
Note: Released By: FREODICA Revision- revised sanitary riser diagram.
PLUM HOLD 10/24/2013 10/24/2013
Note: Held By: FREODICA revision Note: Manual review for this permit only per building official. Provide revised floor plan signed and sealed by design profession to match with submitted revised sanitary riser diagram per 2010 FBC 107.2.1.
ELEC COMPLETE 09/27/2013 09/27/2013
BLD COMPLETE 09/17/2013 09/17/2013
ELEC HOLD 09/17/2013 09/17/2013
Note: Revise receptacle locations to meet NEC 210.52
ENGIN1 COMPLETE 09/17/2013 09/20/2013
MECH COMPLETE 09/17/2013 09/17/2013
PLUM COMPLETE 09/17/2013 09/17/2013
SW1 COMPLETE 09/17/2013 09/17/2013
UD1 COMPLETE 09/17/2013 09/17/2013
Note: See comment in the general notes Keith King 386-9318009
URB COMPLETE 09/17/2013 09/19/2013
ZON COMPLETE 09/17/2013 09/19/2013

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/28/2014
REINSPECTION FEE ¤40.00 01/28/2014
REINSPECTION FEE ¤40.00 01/28/2014
REVISION ¤40.00 01/28/2014
REVISION ¤40.00 01/28/2014
SITE PLAN 20 ¤20.00 10/04/2013
SURCHARGE FS 533.721 ¤19.44 10/04/2013
SURCHARGE - FS 468.631 ¤19.44 10/04/2013
STORM WATER PERMIT FEES ¤80.00 10/04/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 10/04/2013
NEW RESIDENTIAL INSPECTIONS ¤522.00 10/04/2013
ADMIN FEE ¤20.00 10/04/2013
ELECTRIC FEE ¤216.60 10/04/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 10/04/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 10/04/2013
IMPACT FEE PARKS ¤1,343.98 10/04/2013
IMPACT FEE SCHOOL ¤3,600.00 10/04/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 10/04/2013
MECHANICAL FEE ¤216.60 10/04/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 10/04/2013
PLAN CHECK FEE ¤104.40 10/04/2013
PLUMBING FEE ¤216.60 10/04/2013
Fees Total Due: ¤0.00 Total Paid: ¤9,667.03