I want to search for...

Permit #2013090377

Permit Details

Status: COED

Parcel Id: 15-11-31-2970-00000-1270
CONDITIONED SPACE: 2532 sqft
GARAGE: 577 sqft
SCREEN PORCH (SOLID ROOF) : 491 sqft
OPENED PORCH (WITH ROOF) : 66 sqft
PATIO/DECK (NO ROOF) : 145 sqft
Total Square Footage: 3811 sqft
Block: 00000
Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven
Job Phone: 386-947-4481
Location Address: 27 NORTH PARK CIR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/09/2013
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: CHECK, JOHN & MARGIE

Address

99 LONGFELLOW DRIVE

COLONIA, NJ 07067

Lot: 1270
Contracted Stated Job Value: ¤305,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BOB BELL
Status Location Address State License Number Phone
CANCEL

411 6TH STREET

HOLLY HILL, FL 32117

01612 (Exp: 09/18/2014) 386-252-5555

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/11/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 06/10/2014 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 06/10/2014 APPROVED RLEE
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 06/10/2014 APPROVED RLEE
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/06/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/6/2014 3:17:32 PM 1ST ROUGH PLUMBING AND MONO SLAB NEEDS VERIFICATION FROM UNIVERSAL FOR APPROVAL...VACUM BREAKER AT BACK PORCH SPICKET..WEATHER STRIPPING AT DOORS..NEED TO ADD SOD AT BACK OF PROPERTY TO STOP EROSION
U - SEWER TIE IN 06/05/2014 APPROVED DSPENCER
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 06/05/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 6/5/2014 2:31:00 PM MISSED INSPECTION,NEED LETTER FROM UNIVERSAL
MONOLITHIC SLAB 06/05/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 6/5/2014 2:31:01 PM MISSED INSPECTION,NEED LETTER FROM UNIVERSAL
TIE BEAM / LINTEL 06/05/2014 APPROVED DROCKWELL
Note: approved by Mike Navarra 12/30/13
GRAVITY SEWER TEST 06/05/2014 APPROVED CMINI
FINAL APRON (AFTER POUR/DRIVEWAY) 06/04/2014 APPROVED RGROSS
ROW FINAL 06/04/2014 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 06/03/2014 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 05/14/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 5/14/2014 3:35:25 PM CALLED FPL TO RELEASE POWER AT 300,SPOKE WITH SUSAN
PRE-APRON (PRE-POUR/DRIVEWAY) 04/17/2014 APPROVED GLALIMA
INSULATION 03/31/2014 APPROVED CMINI
ALL ROUGH 03/31/2014 APPROVED CMINI
INSULATION 03/28/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 3/28/2014 3:25:29 PM ALL ROUGH HAS NOT BEEN CALLED IN YET SHOWING OPEN ON PERMIT,NEED TO CALL IN WITH INSULATION AFTER ITEMS ARE CORRECTED..NEED TO FIRE BLOCK CHASE WALLS OPEN TO ATTIC...FBC 302.11TUB TRENCHS NEED TO BE SEALED APPENDIX F 303.3.4.2 approved by mike navarra
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2014 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 3/21/2014 3:31:50 PM ITEMS CORRECTED approved by Mike Navarra
FRAMING 03/05/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 3/5/2014 3:22:22 PM TRUSS REPAIR REVISIONS NEEDED,THREADED ROD DETAIL NEEDED.TIGHTEN THREADED RODS.ENGINEERING CALLING FOR SCAB BRACING.BEARING PONY WALL ABOVE FRONT ENTRY NEEDS TO HAVE DOUBLE TOP PLATES AND ANCHORED FOR CONTINUOUS LOAD PATH.NEED TO HAVE 5`` HEAD PRESSURE ON DWV FBC 312..NEED TO SEAL UNUSED OPENINGS NEC..110.12A..STRAPPING OF ROMEX NEEDS TO BE EVERY 4-1/2`` IN ATTIC CHECK ALL AREAS NEC.334.30..NAIL PLATES ON ELECTRIC NEED WHERE WIRE IS 1-1/4" FROM EDGE OF FRAMING MEMBERS AT DRILLED HOLES AND WHERE IT IS STRAPPED ON EDGE...NEC.300.4..FIREBLOCKING NEEDED FBC..603...WASTE ARM BROKEN AT MASTER..SUPPLY LINES KINCKED..EXHAUST FAN DUCT KINCKED IN MASTER.NOT READY
LATH/BRICK/ WATER BARRIER 03/05/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
WALL SHEATHING 02/04/2014 APPROVED DROCKWELL
Note: approved by Mike Navarra 2/4/14
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/04/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 2/4/2014 3:03:16 PM TRUSSES ON INTERIOR BEARING WALLS NOT ANCHORED/SAME WALL MISSING THREADED RODS/MANY TRUSSES NOT STRAPPED/3PLY GIRDER NOT ANCHORED AT ANY POINT/TRUSS ENGINEERING NOT DONE/ROOF METALS NOT INSTALLED-INCOMPLETE INSPECTION-NOT READY FOR INSPECTION.ROOF SHEATHING ONLY BY UNIVERSAL INSPECTOR AND APPROVED by Mike Navarra
ELECTRIC-TUG 01/15/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 1/15/2014 3:09:52 PM CALLED FPL TO RELEASE POWER AT,200,SPOKE WITH SUSAN approved by Dave Eversole
U - SEWER TIE IN 01/10/2014 Disapproved -FEE REQUIRED DSPENCER
Note: THIS IS A REINSPECTION Inspection Resulted at 1/10/2014 12:19:04 PM NOT CONNECTED TO THE UTILITY DEPARTMENT STANDARDS
U - SEWER TIE IN 12/31/2013 Disapproved -FEE REQUIRED DSPENCER
Note: THIS IS A REINSPECTION Inspection Resulted at 12/31/2013 2:11:56 PM COVERED CANNOT TELL IF TIED IN.GRAVITY SEWER, THE SEWER TIE-IN INSPECTION MUST BE CALLED IN THE DAY BEFORE THE TIE-IN. THE MORNING OF THE TIE-IN THE INSPECTOR MUST BE CONTACTED TO COORDINATE THE TIME OF THE TIE-IN SO HE CAN WITNESS THE TIE-IN. SEE COMMENT IN GENERAL NOTES DANNY SPENCER 386-569-9082
U - SEWER TIE IN 12/30/2013 Disapproved -FEE REQUIRED DSPENCER
Note: Inspection Resulted at 12/30/2013 2:06:36 PM CONNECTION BURIED AND NO CALL RECIEVED TO COORDINATE THE INSPECTION TIME. CANNOT TELL IN CONNECTED OR NOT.
FOUND SURVEY APPROVED (OFFICE) 12/26/2013 APPROVED JMCGOWEN
PLUMBING 1ST ROUGH UNDERGROUND 12/04/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 12/4/2013 3:55:40 PM PLUMBING HAS BEEN COVERED. UNABLE TO INSPECT. approved by Dave Eversole
MONOLITHIC SLAB 12/04/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 12/4/2013 3:55:41 PM OUTSTANDING INSPECTION. UNABLE TO INSPECT. approved by Mike Navarra
PLUMBING 1ST ROUGH UNDERGROUND 11/25/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 11/25/2013 3:06:58 PM RISER DIAGRAHAM DOES NOT MATCH AS-BUILT.SUMMER KITCHEN NOT ON RISER PLAN.SEWER CONNECTIONS ON OPPOSITE SIDE OF HOUSE. partial approval with no notes by Mike Navarra

Review History

Department Status Date In Date Out
PLUM COMPLETE 06/11/2014 06/12/2014
SW1 COMPLETE 06/03/2014 06/03/2014
Note: Released By: JHINDMAN final s
BLD COMPLETE 03/17/2014 03/18/2014
SW1 COMPLETE 12/26/2013 12/26/2013
Note: Released By: JMCGOWEN FOUNDATION SURVEY
ZON COMPLETE 10/07/2013 10/07/2013
ELEC COMPLETE 09/26/2013 09/27/2013
PLUM COMPLETE 09/26/2013 09/26/2013
ZON HOLD 09/26/2013 10/02/2013
Note: Revise color and material sheet to show the trim meets the LRV of 30 or greater for earthtone colors.
BLD COMPLETE 09/18/2013 09/18/2013
ELEC HOLD 09/18/2013 09/18/2013
Note: Provide electric load calculations FBC 107.2.1
ENGIN1 COMPLETE 09/18/2013 09/19/2013
Note: No swale plan required.
MECH COMPLETE 09/18/2013 09/18/2013
PLUM HOLD 09/18/2013 09/18/2013
Note: Provide sanitary riser diagram either signed and sealed by FL design professional or a plumbing contractor with his name and license number indicated on plan/diagram per 2010 FBC 107.1.
SW1 COMPLETE 09/18/2013 09/18/2013
UD1 COMPLETE 09/18/2013 09/18/2013
Note: See comment in the general notes Keith King 386-9318009
URB COMPLETE 09/18/2013 09/19/2013
ZON HOLD 09/18/2013 09/24/2013
Note: Revise color and material sheet to show the trim meets the LRV of 30 or greater for earthtone colors.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REINSPECTION FEE ¤40.00 06/09/2014
REVISION ¤40.00 06/09/2014
SITE PLAN 20 ¤20.00 10/09/2013
SURCHARGE FS 533.721 ¤23.16 10/09/2013
SURCHARGE - FS 468.631 ¤23.16 10/09/2013
STORM WATER PERMIT FEES ¤80.00 10/09/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 10/09/2013
NEW RESIDENTIAL INSPECTIONS ¤640.00 10/09/2013
ADMIN FEE ¤20.00 10/09/2013
ELECTRIC FEE ¤252.00 10/09/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 10/09/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 10/09/2013
IMPACT FEE PARKS ¤1,343.98 10/09/2013
IMPACT FEE SCHOOL ¤3,600.00 10/09/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 10/09/2013
MECHANICAL FEE ¤252.00 10/09/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 10/09/2013
PLAN CHECK FEE ¤128.00 10/09/2013
PLUMBING FEE ¤252.00 10/09/2013
Fees Total Due: ¤0.00 Total Paid: ¤10,162.27