I want to search for...

Permit #2013090617

Permit Details

Status: COED

Parcel Id: 48-11-31-1700-00000-0280
CONDITIONED SPACE: 3088 sqft
CONDITIONED SPACE: 1059 sqft
OPENED PORCH (WITH ROOF) : 491 sqft
OPENED PORCH (WITH ROOF) : 261 sqft
GARAGE: 792 sqft
PATIO/DECK (NO ROOF) : 89 sqft
Total Square Footage: 5780 sqft
Block: 00000
Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I
Job Phone: 386-236-4133
Location Address: 132 WILLOW OAK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/25/2013
NOC: RECORDED
Applicant name: KEVIN MICHAEL MAYS
Owner: ICI FLAGLER RESIDENTIAL HOLDING LLC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 0280
Contracted Stated Job Value: ¤526,056.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

CGC1517573 (Exp: 08/31/2018) 386-236-4133 386-763-7833

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHRIS C KOONTZ
Status Location Address State License Number Phone Fax
INACTIVE

651 CARSWELL AVE

Holly Hill, FL 32117

CAC035563 (Exp: 08/31/2024) (386) 252-1878 (386)252-9703
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/17/2014 FINAL APPROVED JMONTARULI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 04/16/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 4/16/2014 3:17:15 PM WATER HEATER NOT CONNECTED CORRECTLY
BLD - BUILDING FINAL 04/15/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 4/15/2014 3:24:01 PM HOT WATER SHUT OFF AT WATER HEATER PER MANUFACTUR SPECS..
FINAL APRON (AFTER POUR/DRIVEWAY) 04/15/2014 APPROVED - AS NOTED GLALIMA
Note: WORKING ON 36" FLAIR AT END OF DRIVEWAY . AT THE TIME OF INSPECTIONS . PASSED
U -UTILITY RESIDENTIAL FINAL 04/15/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 04/11/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/11/2014 2:21:32 PM HOT WATER SHUT OFF AT WATER HEATER PER MANUFACTUR SPECS...CHECK GFCI RECPT,ALL EXCEPT BATHS AND MAIN KITCHEN..ACCESS HATCHES AND DOORS FROM CONDITIONED SPACE TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED...FBC ENERGY CONSERVATION CODE 402.2.3 ..NEED TO REMOVE CONSTRUCTION DEBRIS ON ADJACENT PROPERTY,NEED TO STABALIZE EROSION ON RIGHT SIDE OF PROPERTY AND SEED AND STRAW AREAS ON BOTH SIDES..POOL CONTRACTER TO TAKE CARE OF HIS DEBRIS BEFORE POOL FINAL
ROW FINAL 04/10/2014 APPROVED - AS NOTED GLALIMA
Note: DUMPSTER WILL BE MOVED . '' HAD ISSUES WHEN TRUCK WAS ON SITE . VACANT LOT LEFT AND A FINAL SITE WALK IS SET FOR ''TUESDAY '' APRIL 15, 2014 . ON SITE WITH G.M FROM I.C.I HOME BUILDERS. SOME OF THE OTHER CLEANUP IS UNDER THE POOL PERMIT . IF ANY ISSUES CALL GARY LA LIMA 386 - 585 - 0287
FINAL APRON (AFTER POUR/DRIVEWAY) 04/10/2014 APPROVED - AS NOTED GLALIMA
Note: SWEEPING OFF ROAD AND MAKEING SOD REPAIR AT TIME OF INSPECTION . WILL CHECK ELEVATIONS OF SIDE WALKS ON MONDAY APRIL 14th DO TO REPAIRS AT END OF SIDE WALK
FINAL SURVEY (OFFICE USE ONLY) 04/01/2014 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 03/17/2014 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 3/17/2014 2:57:05 PM CALLED FPL TO RELEASE POWER AT 230,SPOKE WITH SUSAN
ELECTRIC - EARLY POWER 03/14/2014 Disapproved -FEE REQUIRED RMARVEL
Note: FBC 2010 article105 work needs to be completed before inspection is called
PRE-APRON (PRE-POUR/DRIVEWAY) 03/14/2014 APPROVED GLALIMA
Note: THIS WAS A 2 PART POUR '' CONCRETE FOR PRE - APRON AND SAND 1'' TO 1''1/2 BASE .
PRE-APRON (PRE-POUR/DRIVEWAY) 03/12/2014 PARTIALLY APPROVED GLALIMA
Note: PRE APRON READY
GRAVITY SEWER TEST 02/27/2014 APPROVED CMINI
U - SEWER TIE IN 02/26/2014 APPROVED DSPENCER
INSULATION 02/03/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 01/31/2014 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 1/31/2014 3:47:32 PM REMOVE DRYWALL FOR INSPECTION.
INSULATION 01/30/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/30/2014 3:17:58 PM NOT READY FOR INSPECTION
LATH/BRICK/ WATER BARRIER 01/27/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 01/27/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 01/24/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/24/2014 3:07:45 PM NAIL PLATES ON ELECTRIC,CHECK ALL, NEC 330..NAIL PLATE ON PLUMBING,CHECK ALL...FLEX DUCT THRU FIRE RATED ASSEMBLY PROHIBITED.. FLOOR,CEILING,WALL.FBC.R..M1601.1.2.7.. NEED TO STRAP ROMEX EVERY 4-1/2 FEET IN ATTIC,CHECK ALL NEC 334.0...DRYER DUCT MUST BE SUPPORTED EVERY 4`` INTERVALS AND SECURED IN PLACE. FBC.M1502.4.2
LATH/BRICK/ WATER BARRIER 01/24/2014 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 1/24/2014 3:07:45 PM NOT READY
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/16/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
WALL SHEATHING 01/14/2014 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/10/2014 CANCELLED BY APPLICANT DROCKWELL
Note: Inspection Resulted at 1/10/2014 3:34:54 PM WILLIAM CALLED AT 12:30 TO CANCEL
ELECTRIC-TUG 12/18/2013 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 12/18/2013 3:06:04 PM CALLED FPL TO RELEASE POWER AT 145,SPOKE WITH SUSAN
TIE BEAM / LINTEL 12/12/2013 APPROVED DROCKWELL
ELEV CERT-FOUNDATION APPROVAL 12/11/2013 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 12/11/2013 APPROVED JMCGOWEN
MONOLITHIC SLAB 11/27/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 11/26/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 11/26/2013 3:25:03 PM INTERIOR BEARING WALL NEEDS TO BE EXTENDED PER APPROVED PLANS.
PLUMBING 1ST ROUGH UNDERGROUND 11/19/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
PLFM COMPLETE 04/02/2014 04/07/2014
SW1 COMPLETE 04/01/2014 04/01/2014
Note: Released By: JHINDMAN
BLD COMPLETE 01/08/2014 01/09/2014
PLFM COMPLETE 12/11/2013 12/11/2013
SW1 COMPLETE 12/11/2013 12/11/2013
Note: Released By: JMCGOWEN foundation survey
PLFM COMPLETE 10/17/2013 10/22/2013
MECH COMPLETE 10/17/2013 10/17/2013
ELEC COMPLETE 10/17/2013 10/17/2013
BLD COMPLETE 10/17/2013 10/17/2013
PLFM HOLD 10/04/2013 10/04/2013
Note: Complete section C1
BLD HOLD 09/27/2013 10/01/2013
Note: 1. Provide attic ventilation calculations. 2010 FBC R 806. 2. Provide gas contractor and gas riser 2010 FBC 107.2.1.
ELEC HOLD 09/27/2013 10/01/2013
Note: 1. Provide co/smoke detector outside of master bedroom. fss 553.895. 2. Provide receptacle spacing in the master bedroom per 2008 NEC 210.52. 3. Provide electrical load calculation 2008 NEC art. 220.
ENGIN1 COMPLETE 09/27/2013 09/30/2013
Note: No swale plan required.
MECH HOLD 09/27/2013 09/30/2013
Note: Provide return air from bedroom 4 to comply with 2010 FBC R M1602.4.
PLUM COMPLETE 09/27/2013 09/30/2013
SW1 COMPLETE 09/27/2013 09/30/2013
UD1 COMPLETE 09/27/2013 09/30/2013
Note: See comment in the general notes Keith King 386-9318009
URB COMPLETE 09/27/2013 09/30/2013
ZON COMPLETE 09/27/2013 10/04/2013

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/17/2014
REINSPECTION FEE ¤40.00 04/17/2014
REINSPECTION FEE ¤40.00 04/17/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REINSPECTION FEE ¤40.00 04/01/2014
REVISION ¤40.00 04/01/2014
SITE PLAN 20 ¤20.00 10/25/2013
SURCHARGE FS 533.721 ¤36.20 10/25/2013
SURCHARGE - FS 468.631 ¤36.20 10/25/2013
STORM WATER PERMIT FEES ¤80.00 10/25/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 10/25/2013
NEW RESIDENTIAL INSPECTIONS ¤1,054.00 10/25/2013
ADMIN FEE ¤20.00 10/25/2013
ELECTRIC FEE ¤376.20 10/25/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 10/25/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 10/25/2013
IMPACT FEE PARKS ¤1,343.98 10/25/2013
IMPACT FEE SCHOOL ¤3,600.00 10/25/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 10/25/2013
MECHANICAL FEE ¤376.20 10/25/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 10/25/2013
PLAN CHECK FEE ¤210.80 10/25/2013
PLUMBING FEE ¤376.20 10/25/2013
Fees Total Due: ¤0.00 Total Paid: ¤10,977.75