I want to search for...
Permit #2013090617
Permit Details
Status: COED
| Parcel Id: 48-11-31-1700-00000-0280 |
| CONDITIONED SPACE: 3088 sqft |
| CONDITIONED SPACE: 1059 sqft |
| OPENED PORCH (WITH ROOF) : 491 sqft |
| OPENED PORCH (WITH ROOF) : 261 sqft |
| GARAGE: 792 sqft |
| PATIO/DECK (NO ROOF) : 89 sqft |
| Total Square Footage: 5780 sqft |
| Block: 00000 |
| Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I |
| Job Phone: 386-236-4133 |
| Location Address: 132 WILLOW OAK WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/25/2013 |
| NOC: RECORDED |
| Applicant name: KEVIN MICHAEL MAYS |
| Owner: ICI FLAGLER RESIDENTIAL HOLDING LLC |
|
Address 2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
| Lot: 0280 |
| Contracted Stated Job Value: ¤526,056.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
CGC1517573 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
CHRIS C KOONTZ
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
651 CARSWELL AVE Holly Hill, FL 32117 |
CAC035563 (Exp: 08/31/2024) | (386) 252-1878 | (386)252-9703 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/17/2014 | FINAL APPROVED | JMONTARULI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 04/16/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/16/2014 3:17:15 PM WATER HEATER NOT CONNECTED CORRECTLY | |||
| BLD - BUILDING FINAL | 04/15/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/15/2014 3:24:01 PM HOT WATER SHUT OFF AT WATER HEATER PER MANUFACTUR SPECS.. | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 04/15/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: WORKING ON 36" FLAIR AT END OF DRIVEWAY . AT THE TIME OF INSPECTIONS . PASSED | |||
| U -UTILITY RESIDENTIAL FINAL | 04/15/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 04/11/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 4/11/2014 2:21:32 PM HOT WATER SHUT OFF AT WATER HEATER PER MANUFACTUR SPECS...CHECK GFCI RECPT,ALL EXCEPT BATHS AND MAIN KITCHEN..ACCESS HATCHES AND DOORS FROM CONDITIONED SPACE TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED...FBC ENERGY CONSERVATION CODE 402.2.3 ..NEED TO REMOVE CONSTRUCTION DEBRIS ON ADJACENT PROPERTY,NEED TO STABALIZE EROSION ON RIGHT SIDE OF PROPERTY AND SEED AND STRAW AREAS ON BOTH SIDES..POOL CONTRACTER TO TAKE CARE OF HIS DEBRIS BEFORE POOL FINAL | |||
| ROW FINAL | 04/10/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: DUMPSTER WILL BE MOVED . '' HAD ISSUES WHEN TRUCK WAS ON SITE . VACANT LOT LEFT AND A FINAL SITE WALK IS SET FOR ''TUESDAY '' APRIL 15, 2014 . ON SITE WITH G.M FROM I.C.I HOME BUILDERS. SOME OF THE OTHER CLEANUP IS UNDER THE POOL PERMIT . IF ANY ISSUES CALL GARY LA LIMA 386 - 585 - 0287 | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 04/10/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: SWEEPING OFF ROAD AND MAKEING SOD REPAIR AT TIME OF INSPECTION . WILL CHECK ELEVATIONS OF SIDE WALKS ON MONDAY APRIL 14th DO TO REPAIRS AT END OF SIDE WALK | |||
| FINAL SURVEY (OFFICE USE ONLY) | 04/01/2014 | APPROVED | JHINDMAN |
| ELECTRIC - EARLY POWER | 03/17/2014 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/17/2014 2:57:05 PM CALLED FPL TO RELEASE POWER AT 230,SPOKE WITH SUSAN | |||
| ELECTRIC - EARLY POWER | 03/14/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: FBC 2010 article105 work needs to be completed before inspection is called | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 03/14/2014 | APPROVED | GLALIMA |
| Note: THIS WAS A 2 PART POUR '' CONCRETE FOR PRE - APRON AND SAND 1'' TO 1''1/2 BASE . | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 03/12/2014 | PARTIALLY APPROVED | GLALIMA |
| Note: PRE APRON READY | |||
| GRAVITY SEWER TEST | 02/27/2014 | APPROVED | CMINI |
| U - SEWER TIE IN | 02/26/2014 | APPROVED | DSPENCER |
| INSULATION | 02/03/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 01/31/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/31/2014 3:47:32 PM REMOVE DRYWALL FOR INSPECTION. | |||
| INSULATION | 01/30/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 1/30/2014 3:17:58 PM NOT READY FOR INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 01/27/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/27/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 01/24/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 1/24/2014 3:07:45 PM NAIL PLATES ON ELECTRIC,CHECK ALL, NEC 330..NAIL PLATE ON PLUMBING,CHECK ALL...FLEX DUCT THRU FIRE RATED ASSEMBLY PROHIBITED.. FLOOR,CEILING,WALL.FBC.R..M1601.1.2.7.. NEED TO STRAP ROMEX EVERY 4-1/2 FEET IN ATTIC,CHECK ALL NEC 334.0...DRYER DUCT MUST BE SUPPORTED EVERY 4`` INTERVALS AND SECURED IN PLACE. FBC.M1502.4.2 | |||
| LATH/BRICK/ WATER BARRIER | 01/24/2014 | Disapproved - NO FEE | CMINI |
| Note: Inspection Resulted at 1/24/2014 3:07:45 PM NOT READY | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/16/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| WALL SHEATHING | 01/14/2014 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/10/2014 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: Inspection Resulted at 1/10/2014 3:34:54 PM WILLIAM CALLED AT 12:30 TO CANCEL | |||
| ELECTRIC-TUG | 12/18/2013 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 12/18/2013 3:06:04 PM CALLED FPL TO RELEASE POWER AT 145,SPOKE WITH SUSAN | |||
| TIE BEAM / LINTEL | 12/12/2013 | APPROVED | DROCKWELL |
| ELEV CERT-FOUNDATION APPROVAL | 12/11/2013 | APPROVED | CBENTLEY |
| FOUND SURVEY APPROVED (OFFICE) | 12/11/2013 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 11/27/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 11/26/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 11/26/2013 3:25:03 PM INTERIOR BEARING WALL NEEDS TO BE EXTENDED PER APPROVED PLANS. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/19/2013 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 04/02/2014 | 04/07/2014 |
| SW1 | COMPLETE | 04/01/2014 | 04/01/2014 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 01/08/2014 | 01/09/2014 |
| PLFM | COMPLETE | 12/11/2013 | 12/11/2013 |
| SW1 | COMPLETE | 12/11/2013 | 12/11/2013 |
| Note: Released By: JMCGOWEN foundation survey | |||
| PLFM | COMPLETE | 10/17/2013 | 10/22/2013 |
| MECH | COMPLETE | 10/17/2013 | 10/17/2013 |
| ELEC | COMPLETE | 10/17/2013 | 10/17/2013 |
| BLD | COMPLETE | 10/17/2013 | 10/17/2013 |
| PLFM | HOLD | 10/04/2013 | 10/04/2013 |
| Note: Complete section C1 | |||
| BLD | HOLD | 09/27/2013 | 10/01/2013 |
| Note: 1. Provide attic ventilation calculations. 2010 FBC R 806. 2. Provide gas contractor and gas riser 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 09/27/2013 | 10/01/2013 |
| Note: 1. Provide co/smoke detector outside of master bedroom. fss 553.895. 2. Provide receptacle spacing in the master bedroom per 2008 NEC 210.52. 3. Provide electrical load calculation 2008 NEC art. 220. | |||
| ENGIN1 | COMPLETE | 09/27/2013 | 09/30/2013 |
| Note: No swale plan required. | |||
| MECH | HOLD | 09/27/2013 | 09/30/2013 |
| Note: Provide return air from bedroom 4 to comply with 2010 FBC R M1602.4. | |||
| PLUM | COMPLETE | 09/27/2013 | 09/30/2013 |
| SW1 | COMPLETE | 09/27/2013 | 09/30/2013 |
| UD1 | COMPLETE | 09/27/2013 | 09/30/2013 |
| Note: See comment in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 09/27/2013 | 09/30/2013 |
| ZON | COMPLETE | 09/27/2013 | 10/04/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/17/2014 |
| REINSPECTION FEE | ¤40.00 | 04/17/2014 |
| REINSPECTION FEE | ¤40.00 | 04/17/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REINSPECTION FEE | ¤40.00 | 04/01/2014 |
| REVISION | ¤40.00 | 04/01/2014 |
| SITE PLAN 20 | ¤20.00 | 10/25/2013 |
| SURCHARGE FS 533.721 | ¤36.20 | 10/25/2013 |
| SURCHARGE - FS 468.631 | ¤36.20 | 10/25/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 10/25/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 10/25/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤1,054.00 | 10/25/2013 |
| ADMIN FEE | ¤20.00 | 10/25/2013 |
| ELECTRIC FEE | ¤376.20 | 10/25/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 10/25/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 10/25/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 10/25/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/25/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 10/25/2013 |
| MECHANICAL FEE | ¤376.20 | 10/25/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 10/25/2013 |
| PLAN CHECK FEE | ¤210.80 | 10/25/2013 |
| PLUMBING FEE | ¤376.20 | 10/25/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,977.75 |