I want to search for...

Permit #2013100257

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-0230
CONDITIONED SPACE: 3299 sqft
GARAGE: 1013 sqft
PATIO/DECK (NO ROOF) : 88 sqft
OPENED PORCH (WITH ROOF) : 613 sqft
Total Square Footage: 5013 sqft
Block: 00000
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-947-4481
Location Address: 222 WILLOW OAK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/25/2013
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: OLSEN CUSTOM HOMES & CONSULTING INC

Address

131 MAGNOLIA AVENUE

DAYTONA BEACH, FL 32114

Lot: 0230
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BOB BELL
Status Location Address State License Number Phone
CANCEL

411 6TH STREET

HOLLY HILL, FL 32117

01612 (Exp: 09/18/2014) 386-252-5555

Inspection History

Type Request Date Result Inspector
WALL SHEATHING 04/04/2014 APPROVED RLEE
Note: THIS IS A REINSPECTION See inspection letter from Universal Engineering of approval.
U -UTILITY RESIDENTIAL FINAL 04/01/2014 FINAL APPROVED DSPENCER
ELECTRIC - EARLY POWER 03/18/2014 APPROVED CMINI
Note: called fpl to release power
BLD - BUILDING FINAL 03/17/2014 FINAL APPROVED CMINI
FINAL SURVEY (OFFICE USE ONLY) 03/11/2014 APPROVED JHINDMAN
BLD - BUILDING FINAL 03/10/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 3/10/2014 3:42:17 PM NOT READY..FINAL SURVEY REQUIRED..INTERSYSTEM BONDING FOR OTHER MEAN NEEDS TO BE INSTALLED 250.94 ..SINKS AND FIXTURES NEED TO BE INSTALLED..NON WEATHER PROOF OUTLET OUTSIDE NEEDS TO BE REMOVED...ALL HABITABLE ROOM MUST HAVE A SWITCHED LIGHT..NEC 210.70.INCOMPLETE INSPECTION.
FINAL APRON (AFTER POUR/DRIVEWAY) 03/07/2014 APPROVED GLALIMA
ROW FINAL 03/07/2014 APPROVED - AS NOTED GLALIMA
Note: WAITING FOR DUMPSTER TRUCK . WILL DO DRIVE BY TO SEE IF ANY DAMAGE .
PRE-APRON (PRE-POUR/DRIVEWAY) 02/25/2014 PARTIALLY APPROVED GLALIMA
Note: CONCRETE PERPOUR APRON
INSULATION 02/12/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
FRAMING 02/12/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/12/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/11/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 2/11/2014 3:38:49 PM THREADED ROD PER PLAN STILL MISSING,CIRCLED ON PLAN IN MASTER..
INSULATION 02/11/2014 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 2/11/2014 3:38:50 PM MISSING 5`` HEAD PRESSURE ON DWV FBC.312 .....
FRAMING 02/11/2014 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 2/11/2014 3:38:49 PM MISSING 5`` HEAD PRESSURE ON DWV FBC.312 .....
FRAMING 02/10/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 2/10/2014 3:28:54 PM MISSING THREADED ROD IN MASTER BED RM PER PLAN..NEED TO CALL IN INSPECTION 2460 ROOF SHEATHING AT THIS TIME AFTER CORRECTION HAS BEEN MADE TO CLICK OFF INSPECTION 2460 approved by Mike Navarra see report on file
ALL ROUGH 02/10/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 2/10/2014 3:28:53 PM MISSING 5`` HEAD PRESSURE ON DWV FBC.312 ..... approved by Mike Navarra
INSULATION 02/10/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 2/10/2014 3:28:53 PM ACCESS HATCHES AND DOORS FROM CONDITIONED SPACE TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED.BAFFLES RETAINER ARE REQUIRED TO BE PROVIDED WHEN LOOSE FILL INSULATION IS INSTALLED FROM SPILLING INTO LIVING SPACE TO PROVIDE PERMANENT MEANS OF R-VALUE OF LOOSE INSULATION..FBC ENERGY CONSERVATION CODE 402.2.3 ..NEED TO SEAL THREADED ROD ANNULAR SPACE IN MASTER BATH TOP PLATE
FRAMING 02/05/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 2/5/2014 3:20:38 PM MISSING THREADED RODS VARIOUS LOCATIONS/FIRE BLOCKING INCOMPLETE approved as noted tie blocking / truss straps per Mike Navarra
ALL ROUGH 02/05/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 2/5/2014 3:20:37 PM MISSING OUTLET ON PLAN IN GARAGE/NO TEST ON DWV LINES
LATH/BRICK/ WATER BARRIER 02/03/2014 AUDIT - PRIVATE PROVIDER INSPECTION DROCKWELL
Note: Inspection Resulted at 2/3/2014 3:09:37 PM APPROVED....DR approved by Mike Navarra
WALL SHEATHING 01/29/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/29/2014 3:27:32 PM UNABLE TO VERIFY WALL SHEATHING NAIL PATTERN,WALLS COVERED BY TYVEK approved by Mike Navarra 1/29/14
U - SEWER TIE IN 01/27/2014 APPROVED DSPENCER
WALL SHEATHING 01/08/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 1/8/2014 2:29:50 PM NOT COMPLETE approved by Dave Eversole
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/08/2014 AUDIT - PRIVATE PROVIDER INSPECTION CMINI
Note: Inspection Resulted at 1/8/2014 2:29:50 PM REMOVE MANY SHINERS..BRACES,STRAPPING AND ANCHORING NOT COMPLETE..TRUSS REPAIR SHEET NEEDED..NEED DETAIL ON HOW LVL ARE TO HAVE CONTINUOUS LOAD PATH ON BLOCK AT FRONT ENTRY..NOT READY FOR ROOF SHEATHING,BRACES,TIES AND DOWN CELL INSPECTION THAT WAS CALLED IN partial approval by Dave Eversole "tie down is a partial" approved as noted tie blocking / truss straps per Mike Navarra 2/5/14 approved by Mike Navarra
ELECTRIC-TUG 01/08/2014 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 1/8/2014 2:29:52 PM CALLED FPL TO RELEASE POWERAT 130,SPOKE WITH SUSAN approved by Dave Eversole
ELECTRIC-TUG 01/07/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/7/2014 2:04:36 PM NO BREAKER INSTALLED FOR RECEPTACLE rejected by Mike Navarra no notes
TIE BEAM / LINTEL 12/19/2013 AUDIT - PRIVATE PROVIDER INSPECTION DROCKWELL
Note: Inspection Resulted at 12/19/2013 2:59:33 PM APPROVED BY DR approved by mike Navarra
ELEV CERT-FOUNDATION APPROVAL 12/17/2013 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 12/16/2013 APPROVED JMCGOWEN
MONOLITHIC SLAB 12/03/2013 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 12/3/2013 3:20:20 PM UNABLE TO INSPECT. OUTSTANDING INSPECTION. approved by Mike Navarra
PLUMBING 1ST ROUGH UNDERGROUND 12/03/2013 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 12/3/2013 3:20:19 PM NO REVISION ON SITE. UNABLE TO INSPECT. WORK HAS BEEN COVERED.
PLUMBING 1ST ROUGH UNDERGROUND 11/25/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 11/25/2013 3:07:00 PM RISER DIAGRAHAM DOES NOT MATCH AS-BUILT PLUMBING.SEWER CONNECTIONS ARE OPPOSITE approved by Dave Eversole

Review History

Department Status Date In Date Out
PLFM COMPLETE 03/11/2014 03/12/2014
SW1 COMPLETE 03/11/2014 03/11/2014
Note: Released By: JHINDMAN final survey
ELEC COMPLETE 02/07/2014 02/07/2014
PLFM COMPLETE 12/17/2013 12/17/2013
SW1 COMPLETE 12/16/2013 12/16/2013
Note: Released By: JMCGOWEN foundation survey
BLD COMPLETE 12/05/2013 12/05/2013
PLUM COMPLETE 11/27/2013 11/27/2013
URB COMPLETE 10/22/2013 10/23/2013
MECH COMPLETE 10/22/2013 10/23/2013
BLD COMPLETE 10/16/2013 10/17/2013
MECH HOLD 10/16/2013 10/17/2013
Note: Previous comment item1 shall be addressed - 1. Provide hvac equipment sizing calculation for the Master Suite - System 2 per 2010 FBC EC 403.6.1. Note: Equipment sizing shall include manufacturer model number of selected outdoor and indoor units and their performance data.
URB HOLD 10/16/2013 10/17/2013
Note: Need 3 shade trees and 1 understory tree.
ZON COMPLETE 10/16/2013 10/22/2013
BLD HOLD 10/09/2013 10/10/2013
Note: 1. Provide a garage/house door seperation that complies with 2010 FBC R302.5. 2. Provide an exterior door landing at the garage that complies with 2010 FBC R311.3.
ELEC COMPLETE 10/09/2013 10/10/2013
ENGIN1 COMPLETE 10/09/2013 10/09/2013
Note: No swale plan required.
MECH HOLD 10/09/2013 10/10/2013
Note: 1. Provide hvac equipment sizing calculation for the Master Suite - System 2 per 2010 FBC EC 403.6.1. 2. Clarify the hvac equipment efficiency serving master suite and main house per 2010 FBC 107.2.1. Energy calculations and EPL Display Card show both units as 13 SEER but the hvac plan shows 15 SEER for master suite and 16 SEER for main house.
PLFM COMPLETE 10/09/2013 10/17/2013
PLUM COMPLETE 10/09/2013 10/10/2013
SW1 COMPLETE 10/09/2013 10/10/2013
UD1 COMPLETE 10/09/2013 10/10/2013
Note: See comment in the general notes Keith King 386-9318009
URB HOLD 10/09/2013 10/10/2013
Note: 3 Magnolia trees not shown on landscape plan. Irrigation plan not legible.
ZON HOLD 10/09/2013 10/15/2013
Note: Revise building plan to show the depth of 3rd car garage.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REINSPECTION FEE ¤40.00 04/02/2014
REVISION ¤40.00 04/02/2014
REVISION ¤40.00 04/02/2014
REVISION ¤40.00 04/02/2014
SITE PLAN 20 ¤20.00 10/25/2013
SURCHARGE FS 533.721 ¤30.47 10/25/2013
SURCHARGE - FS 468.631 ¤30.47 10/25/2013
STORM WATER PERMIT FEES ¤80.00 10/25/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 10/25/2013
NEW RESIDENTIAL INSPECTIONS ¤872.00 10/25/2013
ADMIN FEE ¤20.00 10/25/2013
ELECTRIC FEE ¤321.60 10/25/2013
3% FIRE IMPACT FEE CREDIT (¤6.24) 10/25/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 10/25/2013
IMPACT FEE PARKS ¤1,343.98 10/25/2013
IMPACT FEE SCHOOL ¤3,600.00 10/25/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 10/25/2013
MECHANICAL FEE ¤321.60 10/25/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 10/25/2013
PLAN CHECK FEE ¤174.40 10/25/2013
PLUMBING FEE ¤321.60 10/25/2013
Fees Total Due: ¤0.00 Total Paid: ¤10,664.09