I want to search for...

Permit #2013100347

Permit Details

Status: COED

Parcel Id: 05-11-31-5918-00000-1190
CONDITIONED SPACE: 2400 sqft
GARAGE: 528 sqft
SCREEN PORCH (SOLID ROOF) : 216 sqft
OPENED PORCH (WITH ROOF) : 54 sqft
Total Square Footage: 3198 sqft
Block: 00000
Subdivision: 2244 - VILLAGE AT PALM COAST PH 1
Job Phone: 386-236-4133
Location Address: 68 LONGVIEW WAY N
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/01/2013
NOC: RECORDED
Applicant name: KEVIN MICHAEL MAYS
Owner: INTERVEST CONSTRUCTION INC

Address

2379 BEVILLE RD

DAYTONA BEACH, FL 32119

Lot: 1190
Contracted Stated Job Value: ¤290,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

CGC1517573 (Exp: 08/31/2018) 386-236-4133 386-763-7833

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHRIS C KOONTZ
Status Location Address State License Number Phone Fax
INACTIVE

651 CARSWELL AVE

Holly Hill, FL 32117

CAC035563 (Exp: 08/31/2024) (386) 252-1878 (386)252-9703
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/16/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 06/12/2014 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/11/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/11/2014 3:23:52 PM MOCP RATING UNIT LABELING. AIR HANDLER...FBC.R. M1303...ARC SHIELDS NEED TO BE PROPERLY INSTALLED AT MIRROR,CAN NOT CUT/ALTER UL LISTED PRODUCTS IN ANY WAY..NEC 314.20..ALL RECEPTACLES NEED TO BE GFCI PROTECTED IN GARAGE 210.8(A)
FINAL SURVEY (OFFICE USE ONLY) 06/10/2014 APPROVED JHINDMAN
FINAL APRON (AFTER POUR/DRIVEWAY) 06/10/2014 APPROVED GLALIMA
ROW FINAL 06/10/2014 APPROVED GLALIMA
PRE-APRON (PRE-POUR/DRIVEWAY) 05/15/2014 APPROVED - AS NOTED GLALIMA
Note: SEE PINK PAINT , NEED TO CLEAN UP BEFOR POUR
ELECTRIC - EARLY POWER 05/07/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 5/7/2014 3:38:23 PM CALLED FPL TO RELEASE POWER AT 1:45 SPOKE WITH SUSAN
GRAVITY SEWER TEST 04/23/2014 APPROVED CMINI
U - SEWER TIE IN 04/23/2014 APPROVED DSPENCER
LATH/BRICK/ WATER BARRIER 03/21/2014 APPROVED CMINI
INSULATION 03/14/2014 APPROVED RMARVEL
ALL ROUGH 03/11/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 03/04/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 3/4/2014 3:30:45 PM MISSING SUPPLY LINE IN GREAT ROOM PER PLAN..220 LINE INTO BOX NEEDS TO HAVE CONNECTOR OR BUSHING..NEC 110.....SECURING AND SUPPORTING OF NM CABLE SHALL BE SUPPORTED AND SECURED EVERY 4-1/2`` CHECK ALL IN ATTIC AREA..NEC 334.40..HOOD VENT NOT INSTALLED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/27/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/11/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 2/11/2014 3:38:44 PM NEED TO SHOW DETAIL REVISION ON TRUSSES A13 WITH ADDED LEGS TO BEARING WALL...TRUSS HA5 MISSING STRAP...TRUSS D NOT SITTING ON DOUBLE TOP PLATE..BEARING WALL NOT 24" O.C. THAT G TRUSSES SITTING ON
ELEV CERT-FOUNDATION APPROVAL 02/11/2014 APPROVED CBENTLEY
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/06/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 2/6/2014 1:49:21 PM ALL STRAPPING AND ANCHORING AND BRACING NEED TO BE DONE AT THIS INSPECTION..BUMPED ROOF AND KNOCKED CELLS..
TIE BEAM / LINTEL 01/21/2014 APPROVED CMINI
FOUND SURVEY APPROVED (OFFICE) 01/16/2014 APPROVED JMCGOWEN
MONOLITHIC SLAB 01/06/2014 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 12/26/2013 APPROVED CMINI

Review History

Department Status Date In Date Out
PLFM COMPLETE 06/12/2014 06/13/2014
PLFM HOLD 06/11/2014 06/12/2014
Note: 1. Section B7 has the incorrect date. 2. Section D check box for attachments.
SW1 COMPLETE 06/10/2014 06/10/2014
Note: Released By: JHINDMAN final survey
BLD COMPLETE 02/20/2014 02/20/2014
Note: Revision - truss repair
PLFM HOLD 01/17/2014 02/17/2014
Note: Within Section D, please modify the date signed by surveyor. Two years are depicted.
SW1 COMPLETE 01/16/2014 01/16/2014
Note: Released By: JMCGOWEN foundation survey
PLUM COMPLETE 12/19/2013 12/20/2013
Note: Released By: FREODICA Revision - changed sanitary riser diagram.
BLD COMPLETE 10/21/2013 10/21/2013
ELEC COMPLETE 10/21/2013 10/21/2013
ZON COMPLETE 10/21/2013 10/24/2013
BLD HOLD 10/14/2013 10/14/2013
Note: 1. Provide garage/house seperation door per 2010 FBC R302.5.
ELEC HOLD 10/14/2013 10/14/2013
Note: Revise receptacle locations to meet NEC 210.52
ENGIN1 COMPLETE 10/14/2013 10/14/2013
Note: No swale plan required.
MECH COMPLETE 10/14/2013 10/14/2013
PLUM COMPLETE 10/14/2013 10/14/2013
SW1 COMPLETE 10/14/2013 10/14/2013
UD1 COMPLETE 10/14/2013 10/15/2013
Note: See comment in the general notes Keith King 386-9318009
URB COMPLETE 10/14/2013 10/15/2013
ZON HOLD 10/14/2013 10/17/2013
Note: Revise landscape and site plan to remove proposed pool and show landscaping at rear of house not proposed pool.
PLFM COMPLETE 02/20/2014
Note: Released By: DBEVAN

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/11/2014
REINSPECTION FEE ¤40.00 05/29/2014
REINSPECTION FEE ¤40.00 05/29/2014
REINSPECTION FEE ¤40.00 05/29/2014
CONTRACTOR CHANGE ¤40.00 05/29/2014
REVISION ¤40.00 05/29/2014
REVISION ¤40.00 05/29/2014
SITE PLAN 20 ¤20.00 11/01/2013
SURCHARGE FS 533.721 ¤21.84 11/01/2013
SURCHARGE - FS 468.631 ¤21.84 11/01/2013
STORM WATER PERMIT FEES ¤80.00 11/01/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 11/01/2013
3% TRANS IMPACT FEE CREDIT (¤90.51) 11/01/2013
ELECTRIC FEE ¤239.40 11/01/2013
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 11/01/2013
IMPACT FEE PARKS ¤1,343.98 11/01/2013
IMPACT FEE SCHOOL ¤3,600.00 11/01/2013
IMPACT FEE TRANSPORTATION ¤3,017.05 11/01/2013
MECHANICAL FEE ¤239.40 11/01/2013
3% PARKS IMPACT FEE CREDIT (¤40.32) 11/01/2013
PLAN CHECK FEE ¤119.60 11/01/2013
PLUMBING FEE ¤239.40 11/01/2013
NEW RESIDENTIAL INSPECTIONS ¤598.00 11/01/2013
ADMIN FEE ¤20.00 11/01/2013
Fees Total Due: ¤0.00 Total Paid: ¤9,827.16