Status: COED
| Parcel Id: 07-11-31-7012-00040-0160 |
| CONDITIONED SPACE: 2485 sqft |
| GARAGE: 461 sqft |
| SCREEN PORCH (SOLID ROOF) : 315 sqft |
| OPENED PORCH (WITH ROOF) : 180 sqft |
| PATIO/DECK (NO ROOF) : 101 sqft |
| Total Square Footage: 3542 sqft |
| Block: 00040 |
| Subdivision: 2187 - SECTION 12-BELLE TERRE |
| Job Phone: (386)446-5161 |
| Location Address: 2 BARRINGTON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/04/2013 |
| NOC: RECORDED |
| Applicant name: HUGO A CAMACHO |
| Owner: IDEAL HOMES AT PALM COAST INC |
|
Address 21 OLD KINGS RD N STE B204 PALM COAST, FL 32164 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤280,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE - MODEL HOME |
| Type: CN |
Contractor
IDEAL HOMES AT PALM COAST, INC.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 353639 PALM COAST, FL 32137 |
CBC1250774 (Exp: 08/31/2026) | (386)446-5161 | (386)447-0238 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
RYSZARD ALOJZY SKLADZIEN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 MARKET PLACE UNIT D PALM COAST, FL 32137 |
CCC057546 (Exp: 08/31/2016) | (386)445-7945 | (386)446-3871 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 07/24/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 07/23/2014 | FINAL APPROVED | CMINI |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 07/15/2014 | APPROVED | RGROSS |
| ROW FINAL | 07/15/2014 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 07/09/2014 | APPROVED | JMCGOWEN |
| ELECTRIC - EARLY POWER | 05/07/2014 | APPROVED | RMARVEL |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/24/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION READY FOR PAVERS | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/22/2014 | PARTIALLY APPROVED | RGROSS |
| Note: Paver driveway. Approved for concrete pour over culvert only. No crushed crete on site. Note that this culvert was raised from the original elevation on the swale sheet w/ the knowledge and approval of the Eng. Dept. | |||
| GRAVITY SEWER TEST | 04/16/2014 | APPROVED | RMARVEL |
| U - SEWER TIE IN | 04/16/2014 | APPROVED | DSPENCER |
| INSULATION | 02/25/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 02/24/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 2/24/2014 2:49:31 PM PROVIDE FIRE BLOCKING/FOAM AT RANGE VENT INTO ATTIC.FIREBLOCKING NEEDED…..F.B.C. 302.11 | |||
| ALL ROUGH | 02/13/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 02/11/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 2/11/2014 3:20:06 PM RECHECK NAIL PLATES.( DINING ROOM) PROVIDE RECEPTACLE WITHIN 6FT OF DOOR IN BEDROOM 3. INSTALL SERVICE FEEDERS AT INTERIOR PANEL AT TIME OF THIS INSPECTION. DO NOT HOOK THEM UP IN EXTERIOR LUGS.(SAFE THEM OFF) APPEARS OUTLET FOR TV IS MISSING IN BEDROOM 2.VERIFY ON PLANS. | |||
| LATH/BRICK/ WATER BARRIER | 02/11/2014 | APPROVED | RMARVEL |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/22/2014 | APPROVED | RMARVEL |
| TIE BEAM / LINTEL | 01/07/2014 | APPROVED | RMARVEL |
| Note: Inspection Resulted at 1/7/2014 2:46:37 PM A PURPLE PRIMER IS REQUIRED TO BE USED. GLUE VENT STACKS WHERE IN BLOCK WALL. 2010 FPC 705.14.2 | |||
| ELECTRIC-TUG | 01/07/2014 | APPROVED | RMARVEL |
| Note: Hugo asked to schedule this inspection Inspection Resulted at 1/7/2014 2:46:38 PM CALLED FPL AT 11:"03 | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/06/2014 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 12/13/2013 | APPROVED | DROCKWELL |
| Note: PER hUGO | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/11/2013 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/27/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 11/27/2013 12:27:48 PM APP-ROVED CITY STAMPED PLUMBING RISER DIAGRAM DOES NOT MATCH WORK PERFORMED. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/09/2014 | 07/09/2014 |
| Note: Released By: JMCGOWEN final s | |||
| ENGIN1 | COMPLETE | 03/24/2014 | 04/02/2014 |
| ZON | COMPLETE | 03/24/2014 | 03/24/2014 |
| MECH | COMPLETE | 02/12/2014 | 02/13/2014 |
| Note: Revision - changed duct layout | |||
| SW1 | COMPLETE | 01/06/2014 | 01/06/2014 |
| Note: Released By: JMCGOWEN foundation survey | |||
| PLUM | COMPLETE | 12/10/2013 | 12/10/2013 |
| Note: Revision - changed sanitary riser diagram and domestic water piping material. | |||
| BLD | COMPLETE | 11/22/2013 | 11/26/2013 |
| ENGIN1 | COMPLETE | 10/24/2013 | 10/24/2013 |
| ELEC | COMPLETE | 10/24/2013 | 10/24/2013 |
| URB | COMPLETE | 10/24/2013 | 10/24/2013 |
| PLUM | COMPLETE | 10/24/2013 | 10/24/2013 |
| ZON | COMPLETE | 10/24/2013 | 10/30/2013 |
| BLD | COMPLETE | 10/14/2013 | 10/15/2013 |
| ELEC | HOLD | 10/14/2013 | 10/15/2013 |
| Note: Revise receptacle locations to meet NEC 210.52, revise service entrance conductor sizes for the proposed 200 amp panel to meet NEC Table 310.15 B 6 | |||
| ENGIN1 | HOLD | 10/14/2013 | 10/14/2013 |
| Note: Provide centerline of road elevations per Palm Coast Technical Manual Section 300.01 A. 1. b. (7) (7) The road centerline and edge of pavement elevations for roadways adjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 O'clock positions. Scott Bombardier 386-986-3756 | |||
| MECH | COMPLETE | 10/14/2013 | 10/15/2013 |
| PLUM | HOLD | 10/14/2013 | 10/15/2013 |
| Note: Sanitary line from summer kitchen sink shows 2 pipe sizes for the same pipe. Clarify which pipe size to be used per 2010 FBC 107.2.1. | |||
| SW1 | COMPLETE | 10/14/2013 | 10/14/2013 |
| UD1 | COMPLETE | 10/14/2013 | 10/15/2013 |
| Note: See comment in the general notes Keith King 386-9318009 | |||
| URB | HOLD | 10/14/2013 | 10/15/2013 |
| Note: 1. Lot size requires 3 more code trees 2.Foundation shrubs needed on Baron Way side of house. | |||
| ZON | HOLD | 10/14/2013 | 10/18/2013 |
| Note: Revise landscaping plan to landscaping along both sides entirely wraping the rear corners. Revise site plan to show 3 additional trees |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 07/28/2014 |
| REVISION | ¤40.00 | 07/28/2014 |
| REVISION | ¤40.00 | 07/28/2014 |
| REVISION | ¤40.00 | 07/28/2014 |
| REINSPECTION FEE | ¤40.00 | 07/28/2014 |
| REINSPECTION FEE | ¤40.00 | 07/28/2014 |
| REINSPECTION FEE | ¤40.00 | 07/28/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤638.00 | 11/04/2013 |
| SITE PLAN 20 | ¤20.00 | 11/04/2013 |
| SURCHARGE FS 533.721 | ¤23.10 | 11/04/2013 |
| SURCHARGE - FS 468.631 | ¤23.10 | 11/04/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/04/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 11/04/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 11/04/2013 |
| MECHANICAL FEE | ¤251.40 | 11/04/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 11/04/2013 |
| PLAN CHECK FEE | ¤127.60 | 11/04/2013 |
| PLUMBING FEE | ¤251.40 | 11/04/2013 |
| ADMIN FEE | ¤20.00 | 11/04/2013 |
| ELECTRIC FEE | ¤251.40 | 11/04/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 11/04/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 11/04/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 11/04/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/04/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,010.45 |