Permit #2013100844
Permit Details
Status: COED
| Parcel Id: 18-11-31-1230-00000-0020 |
| Block: 00000 |
| Subdivision: 2105 - COBBLESTONE VILLAGE |
| Job Phone: (386) 445-2222 |
| Location Address: 260 CYPRESS EDGE DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 12/03/2013 |
| NOC: RECORDED |
| Applicant name: MICHAEL STEPHAN MULLEN |
| Owner: MARY KLEMONSKY & ROBERT ERICKSON |
|
Address 270 CYPRESS POINT PKWY PALM COAST, FL 32164 |
|
Address SUITE A-15 PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤30,000.00 |
| Job Description: UNIT A-15-- INTERIOR BUILDOUT FOR THE "TAN DOCTOR" |
| Type: CN |
Contractor
TOWN & COUNTRY HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 Enterprise Drive Bunnell, FL 32110 |
CGC049972 (Exp: 08/31/2026) | (386) 445-2222 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 03/18/2014 | FINAL APPROVED | RMARVEL |
| FIRE FINAL | 03/17/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC FINAL | 03/17/2014 | APPROVED | RMARVEL |
| ABOVE CEILING | 03/14/2014 | APPROVED - AS NOTED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/14/2014 3:44:20 PM THE 2 FRONT RECESSED CSN WHIPS NEED TO BE HELD OFF THE CEILING GRID BY THEIR OWN SUPPORTWIRES. | |||
| ABOVE CEILING | 03/05/2014 | CANCELLED BY APPLICANT | JHINDMAN |
| FIRE FINAL | 03/05/2014 | CANCELLED BY APPLICANT | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 03/04/2014 | FINAL APPROVED | DSPENCER |
| FIRE FINAL | 03/04/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 3/4/2014 1:45:54 PM 1. FIRE EXTINGUISHERS MUST BE MOUNTED PER NFPA 10 AND THE PLANS. ALL TRADES MUST BE COMPLETED FOR THE FIRE FINAL. J. HINDMAN 986-3784. | |||
| ABOVE CEILING | 03/04/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 3/4/2014 1:45:54 PM 1. THE DRYER VENT MUST BE COMPLETED ABOVE THE BACK ROOM CEILING. 2010 FBC 110.6. 2. THE AREA ABOVE THE CEILING HAS BEEN COVERED BY THE CEILING TILES. THE CEILING MUST BE OPENED UP ENOUGH TO INSPECT. 2010 FBC 110.6. J. HINDMAN 986-3784. | |||
| FRAMING | 01/16/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 01/08/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 1/8/2014 2:29:51 PM PLAN CALLS FOR METAL STUDS,WOOD STUDS INSTALLED..NEED TO SHOW REVISION..20X24 OPENINGS NOT FRAMED OUT FOR GRILLS IN WALLS | |||
| PLUMBING 2ND ROUGH | 01/07/2014 | APPROVED | RMARVEL |
| ELECTRIC 2ND ROUGH | 01/07/2014 | APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 01/15/2014 | 01/15/2014 |
| BLD | COMPLETE | 11/26/2013 | 11/26/2013 |
| ELEC | COMPLETE | 11/18/2013 | 11/18/2013 |
| BLD | HOLD | 11/18/2013 | 11/25/2013 |
| Note: The minimum door width opening at the office shall comply with 2010 FBC 1008.1.1. | |||
| PLUM | COMPLETE | 11/18/2013 | 11/19/2013 |
| MECH | COMPLETE | 11/18/2013 | 11/19/2013 |
| BLD | HOLD | 10/29/2013 | 10/29/2013 |
| Note: 1. Provide manuevering clearance at hallway doors that complies with 2010 FBC accessibility 404.2.4.1. | |||
| ELEC | HOLD | 10/29/2013 | 10/29/2013 |
| Note: Provide existing service panel size and amperage and load calculations NEC article 220 | |||
| FI1 | COMPLETE | 10/29/2013 | 10/29/2013 |
| MECH | HOLD | 10/29/2013 | 10/30/2013 |
| Note: 1. Provide enegry calculations including equipment sizing calculation due to change in occupancy use per 2010 FBC EC 101.4.4. 2. Provide existing hvac unit cooling capacity to verify that it meets the load calculation as requested in item 1 above per 2010 FBC 107.2.1. 3. Provide information on spray booth and tanning bed manufacturer specifications per 2010 FBC 107.2.1. | |||
| PLUM | HOLD | 10/29/2013 | 10/29/2013 |
| Note: 1. Provide sanitary riser and domestic water riser diagrams per 2010 FBC 107.3.5. 2. Provide DWV and domestic water material specifications per 2010 FBC P 702/605. | |||
| SW1 | COMPLETE | 10/29/2013 | 11/06/2013 |
| UD1 | COMPLETE | 10/29/2013 | 10/30/2013 |
| ZON | COMPLETE | 10/29/2013 | 11/04/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 03/19/2014 |
| REINSPECTION FEE | ¤40.00 | 03/19/2014 |
| REINSPECTION FEE | ¤40.00 | 03/19/2014 |
| REVISION | ¤40.00 | 03/19/2014 |
| SITE PLAN 20 | ¤20.00 | 12/03/2013 |
| SURCHARGE FS 533.721 | ¤7.89 | 12/03/2013 |
| SURCHARGE - FS 468.631 | ¤7.89 | 12/03/2013 |
| ADMIN COMMERCIAL | ¤60.00 | 12/03/2013 |
| INSPECTION - COMMERCIAL ADD | ¤210.00 | 12/03/2013 |
| ELECTRIC FEE | ¤78.00 | 12/03/2013 |
| FIRE PLANS REVIEW | ¤25.00 | 12/03/2013 |
| PLAN CHECK FEE | ¤100.00 | 12/03/2013 |
| PLUMBING FEE | ¤78.00 | 12/03/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤746.78 |