Permit #2013100856
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7027-00120-0010 |
| Block: 00120 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: 386-447-2202 |
| Location Address: 36 WOODWARD LN |
| Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION |
| Issue Date: 12/10/2013 |
| NOC: RECORDED |
| Applicant name: MICHAEL J LILLY |
| Owner: VITALE, VAN & ILENE |
|
Address 36 WOODWARD LANE PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: GARAGE DOOR, DRYWALL, WATER HEATER, DUCTWORK, TRUSS REPAIR, ETC |
| Type: CN |
Contractor
SERVPRO OF FLAGLER COUNTY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
2205 DOBBS ROAD BUNNELL, FL 32110 |
CGC1514660 (Exp: 08/31/2024) | 904-429-4457 | 386-206-2188 |
Sub Contractors
JOHN FREDERICK WANERKA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 350214 BUNNELL, FL 32110 |
EC13003318 (Exp: 08/31/2022) | (386)446-9626 | (386)445-3131 |
MARK DANIEL EIDMAN JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LANE UNIT 2C PALM COAST, FL 32137 |
CAC1817213 (Exp: 08/31/2026) | 386-446-8894 |
KENNETH FISHER
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 HICKORY LANE Bunnell, 32110 |
RF0044278 (Exp: 08/30/2027) | (386) 439-8766 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
CHRISTIAN LONG
| Status | Location Address | Phone | Fax |
| ACTIVE |
5 BALLEENGER LN PALM COAST , FL 32164 |
386-445-7047 | 386-439-3014 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/29/2014 | FINAL APPROVED | RMARVEL |
| BLD - BUILDING FINAL | 05/28/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/28/2014 3:38:49 PM RE-ATTACH GROUNDING ELECTRODE TO WATER HEATER AND BOND COOPER LINES TOGETHER. REMOVE UNUSED LINES AND SAFE OFF. GARAGE DOOR NEEDS TO OPERATE PROPERLY. THE GARAGE DOOR IS NOT OPENING. | |||
| BLD - BUILDING FINAL | 05/07/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 5/7/2014 3:22:23 PM PROVIDE EXPANSION TANK/VALVE FOR WATER HEATER. PROVIDE DISCONNECT FOR WATER HEATER. OUTLET AT RIGHT SIDE OF GARAGE NEEDS TO BE GFCI PROTECTED.EXPANSION TANK NEEDED FBC..M2003. | |||
| ALL ROUGH | 05/06/2014 | APPROVED | DROCKWELL |
| HVAC ROUGH | 12/27/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC - EARLY POWER | 12/27/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 12/27/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/27/2013 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 12/26/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 12/26/2013 3:34:57 PM PROVIDE ACCESS FOR INSPECTION. DOORS LOCKED. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/26/2013 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/26/2013 3:34:58 PM PROVIDE ACCESS FOR INSPECTION. DOORS LOCKED. ROOF COMPLETE. WILL NEED TO GET WITH BUILDING OFFICIAL RICKIE LEE. | |||
| ELECTRIC - EARLY POWER | 12/26/2013 | Disapproved - NO FEE | RMARVEL |
| Note: Inspection Resulted at 12/26/2013 3:34:59 PM PROVIDE ACCESS FOR INSPECTION. DOORS LOCKED. | |||
| HVAC ROUGH | 12/26/2013 | Disapproved - NO FEE | RMARVEL |
| Note: Inspection Resulted at 12/26/2013 3:34:58 PM PROVIDE ACCESS FOR INSPECTION. DOORS LOCKED. | |||
| DOWN CELL | 12/20/2013 | APPROVED - AS NOTED | JMCGOWEN |
| Note: THIS IS A REINSPECTION third party post inspection or record | |||
| DOWN CELL | 12/13/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 12/13/2013 3:23:13 PM DOWN CELLS WERE POURED BEFORE INSPECTION.CONTACT BUILDING OFFICIAL MR. RICK LEE AS TO WHAT ACTION MUST BE TAKEN. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/13/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/13/2013 3:23:13 PM PLANS CALL FOR 3/4IN FACING ON DAMAGED GIRDER TRUSS FACING FORWARD.MISSING NAILS IN STRAP LEFT SIDE | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/11/2013 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 12/11/2013 1:06:57 PM MUST FIRST POUR DOWN CELLS TO PLAN BEFORE ROOF SHEATHING INSPECTION. THIS STRUCTURAL WORK SHOULD HAVE BEEN DONE BEFORE ANY LOAD WAS IMPOSED ON IT. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/20/2013 | 12/20/2013 |
| BLD | HOLD | 12/16/2013 | 12/16/2013 |
| Note: We do not review pictures, the review process is for minimum code compliance. Please explain | |||
| MECH | COMPLETE | 11/27/2013 | 12/03/2013 |
| MECH | HOLD | 11/25/2013 | 11/26/2013 |
| Note: Submitted hvac plan shows only location of supply diffusers and return grilles. Provide complete duct layout which includes supply and return duct distribution from hvac units, duct sizes and material specification per 2010 FBC 107.2.1. | |||
| MECH | HOLD | 11/20/2013 | 11/21/2013 |
| Note: Previous comment shall be addressed - Previous comment need to be addressed - Provide hvac plan suitable for review, inspection and construction per 2010 FBC 107.2.1. | |||
| PLUM | COMPLETE | 11/06/2013 | 11/07/2013 |
| MECH | HOLD | 11/06/2013 | 11/07/2013 |
| Note: Previous comment shall be addressed - Provide hvac plan suitable for review, inspection and construction per 2010 FBC 107.2.1. | |||
| BLD | COMPLETE | 11/06/2013 | 11/07/2013 |
| BLD | HOLD | 10/30/2013 | 10/30/2013 |
| Note: 1. Provide Florida product approval with installation instructions for the exterior door and overhead door. 2010 FBC 107.2.1. | |||
| ELEC | COMPLETE | 10/30/2013 | 10/30/2013 |
| MECH | HOLD | 10/30/2013 | 10/30/2013 |
| Note: Provide mechanical scope of work and hvac plan suitable for review, inspection and construction per 2010 FBC 107.2.1. | |||
| PLUM | HOLD | 10/30/2013 | 10/30/2013 |
| Note: Provide location and specifications of water heater per 2010 FBCR P2801. | |||
| ZON | COMPLETE | 10/30/2013 | 11/04/2013 |
| Note: no zoning approval. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/29/2014 |
| REINSPECTION FEE | ¤40.00 | 05/27/2014 |
| REVISION | ¤40.00 | 04/22/2014 |
| REINSPECTION FEE | ¤40.00 | 04/22/2014 |
| REINSPECTION FEE | ¤40.00 | 04/22/2014 |
| REINSPECTION FEE | ¤40.00 | 04/22/2014 |
| REINSPECTION FEE | ¤40.00 | 04/22/2014 |
| REINSPECTION FEE | ¤40.00 | 04/22/2014 |
| ADMIN FEE | ¤20.00 | 12/10/2013 |
| ELECTRIC FEE | ¤84.00 | 12/10/2013 |
| MECHANICAL FEE | ¤84.00 | 12/10/2013 |
| PLAN CHECK FEE | ¤40.00 | 12/10/2013 |
| PLUMBING FEE | ¤84.00 | 12/10/2013 |
| SITE PLAN 20 | ¤20.00 | 12/10/2013 |
| SURCHARGE FS 533.721 | ¤5.28 | 12/10/2013 |
| SURCHARGE - FS 468.631 | ¤5.28 | 12/10/2013 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 12/10/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤702.56 |