I want to search for...
Permit #2013100928
Permit Details
Status: COED
| Parcel Id: 15-11-31-2830-00000-0120 |
| CONDITIONED SPACE: 2160 sqft |
| GARAGE: 490 sqft |
| OPENED PORCH (WITH ROOF) : 137 sqft |
| PATIO/DECK (NO ROOF) : 257 sqft |
| Total Square Footage: 3044 sqft |
| Block: 00000 |
| Subdivision: 1071 - FRONT STREET @ GRAND HAVEN PHASE 1 |
| Job Phone: 386-236-4133 |
| Location Address: 26 LAGARE ST |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/20/2013 |
| NOC: RECORDED |
| Applicant name: KEVIN MICHAEL MAYS |
| Owner: CANTU ELEAZAR & CARMA I H&W |
|
Address 2108 BRANCH OAK TRAIL NASHVILLE, TN 37214 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤267,200.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
CGC1517573 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
CHRIS C KOONTZ
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
651 CARSWELL AVE Holly Hill, FL 32117 |
CAC035563 (Exp: 08/31/2024) | (386) 252-1878 | (386)252-9703 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 05/29/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 05/28/2014 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 05/27/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 5/27/2014 3:38:25 PM SMOKE DETECTORS NOT WORKING PROPERLY..HOUSE NOT COMPLETELY PAINTED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/23/2014 | APPROVED | FREODICA |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/20/2014 | Disapproved - NO FEE | FREODICA |
| Note: Provide sufficient drainage elevation shots to indicate drainage pattern from the back to the front of the house and there shall be no draining or flooding to adjacent properties. | |||
| ROW FINAL | 05/16/2014 | APPROVED | GLALIMA |
| ELECTRIC - EARLY POWER | 05/09/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/9/2014 4:13:37 PM CALLED FPL AT 2:04 | |||
| ELECTRIC - EARLY POWER | 05/08/2014 | CANCELLED BY APPLICANT | CMINI |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 05/07/2014 | APPROVED | GLALIMA |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/29/2014 | APPROVED | GLALIMA |
| Note: WAS INSPECTED READY TO POUR | |||
| INSULATION | 03/19/2014 | APPROVED | CMINI |
| Note: Inspection Resulted at 3/19/2014 10:49:33 AM OK | |||
| LATH/BRICK/ WATER BARRIER | 03/17/2014 | APPROVED | CMINI |
| ALL ROUGH | 03/14/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 03/11/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 3/11/2014 3:02:50 PM NEED TO HAVE APPROVED SET OF ELECTRIC PLANS ON JOB SITE...FRONT WINDOW ATTACHMENTS NOT ANCHORED AT TOP OF ARCHES...REAR SLIDER DOOR MISSING ANCHORS RIGHT SIDE..SERVICE ENTRANCE CABLES NEED TO BE SECURED AND SUPPORTED EVERY 4-1/2`` IN ATTIC NEC 334.30 | |||
| GRAVITY SEWER TEST | 03/07/2014 | APPROVED | CMINI |
| U - SEWER TIE IN | 03/07/2014 | APPROVED | DSPENCER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/21/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/20/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/20/2014 2:57:11 PM NEED TO ANCHOR DOWN BEARING WALL OVER FRONT ENTRY TO PLANS | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/18/2014 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: Inspection Resulted at 2/18/2014 2:56:44 PM WILLIAM CALLED TO CANCEL-ROOF METALS NOT ON | |||
| TIE BEAM / LINTEL | 01/27/2014 | APPROVED | CMINI |
| ELECTRIC-TUG | 01/24/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 1/24/2014 3:07:47 PM CALLED FPL TO RELEASE POWER AT 230,SPOKE WITH SUSAN | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/23/2014 | APPROVED | JMCGOWEN |
| MONOLITHIC SLAB | 01/14/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 01/13/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 1/13/2014 3:24:39 PM RELIEVING ARCH NEEDED IN FOOTING GOING OVER PLUMBING PIPE WHERE PIPES ARE TOUCHING REBAR FBC. P2603.5 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/07/2014 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/23/2014 | 05/23/2014 |
| Note: Released By: FREODICA FINAL SURVEY | |||
| SW1 | HOLD | 05/20/2014 | 05/20/2014 |
| Note: Held By: FREODICA final survey Provide sufficient drainage elevation shots to indicate drainage pattern from the back to the front of the house and there shall be no draining or flooding to adjacent properties. | |||
| SW1 | COMPLETE | 01/23/2014 | 01/23/2014 |
| Note: Released By: JMCGOWEN foundation survey | |||
| PLUM | COMPLETE | 12/20/2013 | 12/20/2013 |
| Note: Released By: JMCGOWEN | |||
| BLD | COMPLETE | 11/12/2013 | 11/13/2013 |
| ZON | COMPLETE | 11/12/2013 | 11/14/2013 |
| BLD | HOLD | 11/01/2013 | 11/04/2013 |
| Note: 1. Provide a garage/house seperation door per 2010 FBC R302.5. | |||
| ELEC | COMPLETE | 11/01/2013 | 11/04/2013 |
| ENGIN1 | COMPLETE | 11/01/2013 | 11/04/2013 |
| Note: No swale plan required. | |||
| MECH | COMPLETE | 11/01/2013 | 11/04/2013 |
| PLUM | COMPLETE | 11/01/2013 | 11/04/2013 |
| SW1 | COMPLETE | 11/01/2013 | 11/04/2013 |
| UD1 | COMPLETE | 11/01/2013 | 11/04/2013 |
| Note: See comment in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 11/01/2013 | 11/04/2013 |
| ZON | HOLD | 11/01/2013 | 11/06/2013 |
| Note: Revise site plan to provide leader line for all setbacks to the closes point. Revise site plan to include the dimension of the a/c pad. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/29/2014 |
| REINSPECTION FEE | ¤40.00 | 05/29/2014 |
| REINSPECTION FEE | ¤40.00 | 05/29/2014 |
| REINSPECTION FEE | ¤40.00 | 05/29/2014 |
| REVISION | ¤40.00 | 05/29/2014 |
| SITE PLAN 20 | ¤20.00 | 11/20/2013 |
| SURCHARGE FS 533.721 | ¤20.39 | 11/20/2013 |
| SURCHARGE - FS 468.631 | ¤20.39 | 11/20/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 11/20/2013 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 11/20/2013 |
| NEW RESIDENTIAL INSPECTIONS | ¤552.00 | 11/20/2013 |
| ADMIN FEE | ¤20.00 | 11/20/2013 |
| ELECTRIC FEE | ¤225.60 | 11/20/2013 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 11/20/2013 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 11/20/2013 |
| IMPACT FEE PARKS | ¤1,343.98 | 11/20/2013 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/20/2013 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 11/20/2013 |
| MECHANICAL FEE | ¤225.60 | 11/20/2013 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 11/20/2013 |
| PLAN CHECK FEE | ¤110.40 | 11/20/2013 |
| PLUMBING FEE | ¤225.60 | 11/20/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,731.93 |