I want to search for...

Permit #2013110047

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7026-00250-0180
CONDITIONED SPACE: 262 sqft
OPENED PORCH (WITH ROOF) : 381 sqft
Total Square Footage: 643 sqft
Block: 00250
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: (386)446-5161
Location Address: 40 PINE CEDAR DR
Type: BA - BUILDING ADDITION
Issue Date: 11/12/2013
NOC: RECORDED
Applicant name: HUGO A CAMACHO
Owner: PEARSON DEBRA HYATT

Address

40 PINE CEDAR DR

PALM COAST, FL 32164

Lot: 0180
Contracted Stated Job Value: ¤30,000.00
Job Description: STORAGE AND BATH ADDITION, BREAKFAST NOOK, AND COVERED PATIO AREA
Type: CN

Contractor

IDEAL HOMES AT PALM COAST, INC.
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CBC1250774 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
HUGO A CAMACHO
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CCC1326139 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 04/10/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 04/07/2014 APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 03/24/2014 APPROVED JMCGOWEN
LATH/BRICK/ WATER BARRIER 01/30/2014 APPROVED DROCKWELL
INSULATION 01/30/2014 APPROVED DROCKWELL
ALL ROUGH 01/27/2014 APPROVED RMARVEL
FRAMING 01/07/2014 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/07/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/02/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 1/2/2014 1:40:42 PM WALL ATTACHMENT TO BLOCK IS CALLING FOR BOLTS INTO BLOCK PER APPROVED PLANS. LOOSE SHEATHING AT RIGHT CORNER. ATTACH PER APPROVED PLANS. EXTERIOR WALL TO SLAB ATTACHMENT NNEDS TO BE INSTALLED TO APPROVED CITY STAMPED PLANS. UNABLE TO CHECK FOR TRUSS ENGINEERING. PROVIDE CITY STAMPED APPROVED PLANS.
TIE BEAM / LINTEL 12/19/2013 APPROVED RMARVEL
FOUND SURVEY APPROVED (OFFICE) 12/18/2013 APPROVED JMCGOWEN
GRAVITY SEWER TEST 12/03/2013 APPROVED DROCKWELL
MONOLITHIC SLAB 12/03/2013 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 11/27/2013 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 11/20/2013 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 11/20/2013 2:49:57 PM PLANS STATE ALL WATER LINES ARE TO BE CPVC.REVISE TO SHOW AS BUILT

Review History

Department Status Date In Date Out
SW1 COMPLETE 03/24/2014 03/24/2014
Note: Released By: JMCGOWEN final survey
SW1 COMPLETE 12/17/2013 12/18/2013
Note: Released By: JMCGOWEN FOUDNATION SURVEY
PLUM COMPLETE 11/25/2013 11/26/2013
Note: Revision - changed domestic water piping material.
BLD COMPLETE 11/22/2013 11/22/2013
Note: Revision on plumbing - no building change.
PLUM HOLD 11/22/2013 11/22/2013
Note: Revision - Provide specifications of water piping material to be used to comply with 2010 FBC P 605.4.
ELEC COMPLETE 11/08/2013 11/08/2013
MECH COMPLETE 11/08/2013 11/12/2013
Note: Existing hvac 3-ton units will be replaced with 4-ton units per revised plan.
BLD COMPLETE 11/08/2013 11/12/2013
PLUM COMPLETE 11/08/2013 11/12/2013
Note: Previously approved and no change in plumbing plan.
BLD HOLD 11/05/2013 11/05/2013
Note: 1. Provide Identify the lintel between the new nook and the rear of the addition. 2010 FBC 107.2.1.
ELEC HOLD 11/05/2013 11/05/2013
Note: Revise receptacle locations to meet NEC 210.52
MECH HOLD 11/05/2013 11/05/2013
Note: Hvac equipment sizing calculation shows heating/cooling load of the existing house and the proposed additions. For clarification, provide the capacity of the existing hvac units to verify if they can handle the additional load based on submitted calculations per 2010 FBC 107.2.1.
PLUM COMPLETE 11/05/2013 11/05/2013
SW1 COMPLETE 11/05/2013 11/05/2013
ZON COMPLETE 11/05/2013 11/07/2013

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 04/09/2014
REINSPECTION FEE ¤40.00 04/09/2014
REINSPECTION FEE ¤40.00 04/09/2014
REMODEL/ADDITION/ACCES INSPECT ¤40.00 11/12/2013
SITE PLAN 20 ¤20.00 11/12/2013
SURCHARGE FS 533.721 ¤5.42 11/12/2013
SURCHARGE - FS 468.631 ¤5.42 11/12/2013
STORM WATER PERMIT FEES ¤80.00 11/12/2013
ADMIN FEE ¤20.00 11/12/2013
ELECTRIC FEE ¤87.00 11/12/2013
MECHANICAL FEE ¤87.00 11/12/2013
PLAN CHECK FEE ¤40.00 11/12/2013
PLUMBING FEE ¤87.00 11/12/2013
Fees Total Due: ¤0.00 Total Paid: ¤591.84