I want to search for...
Permit #2013120129
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-5320-00000-0170 |
| ENCLOSE EXISTING PORCH TO LIVING : 264 sqft |
| SCREEN PORCH (SOLID ROOF) : 264 sqft |
| Total Square Footage: 528 sqft |
| Block: 00000 |
| Subdivision: 2179 - RIVERGATE SUBDIVISION, PH II |
| Job Phone: (904)731-5580 |
| Location Address: 74 RAINTREE CIR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 12/19/2013 |
| NOC: RECORDED |
| Applicant name: JEFFREY ALLEN BRIAR |
| Owner: ZIER, BRIAN & KAREN |
|
Address 1236 OLD YORK RD BURLINGTON, NJ 08016 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤19,000.00 |
| Job Description: 12 X 22 GLASS WALLS UNDER EXISTING ROOF & ADD 12 X 22 SCREEN ROOM ON NEW SLAB |
| Type: CN |
Contractor
LIFETIME ENCLOSURES INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5521 CHRONICLE COURT JACKSONVILLE, FL 32256 |
CRC028471 (Exp: 08/31/2026) | 904-731-5580 |
Sub Contractors
EARL W FRICK
| Status | Location Address | State License Number | Phone |
| CANCEL |
5065-3 ST AUGUSTINE ROAD JACKSONVILLE, FL 32207 |
ER0015316 (Exp: 08/31/2016) | (904) 737-7770 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 03/18/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 03/14/2014 | FINAL APPROVED | DROCKWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 02/25/2014 | APPROVED | JMCGOWEN |
| ALL ROUGH | 01/30/2014 | APPROVED | DROCKWELL |
| Note: Amy called to schedule this inspection | |||
| MONOLITHIC SLAB | 01/06/2014 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/21/2014 | 02/21/2014 |
| Note: Released By: JMCGOWEN final survey | |||
| ZON | COMPLETE | 02/21/2014 | 02/21/2014 |
| Note: Released By: JGONZALEZ Revision to add door pads | |||
| MECH | COMPLETE | 12/17/2013 | 12/18/2013 |
| ELEC | COMPLETE | 12/17/2013 | 12/18/2013 |
| ZON | COMPLETE | 12/17/2013 | 12/18/2013 |
| BLD | COMPLETE | 12/05/2013 | 12/06/2013 |
| ELEC | HOLD | 12/05/2013 | 12/06/2013 |
| Note: Provide electric drawing showing all outlets per NEC 210.52 [A] | |||
| MECH | HOLD | 12/05/2013 | 12/06/2013 |
| Note: Provide plan and elevations with dimensions of the proposed enclosure of existing lanai with glass walls to determine if the space would require heating and/or cooling per 2010 FBC R301.2.1.2. | |||
| PLUM | COMPLETE | 12/05/2013 | 12/06/2013 |
| Note: Not applicable | |||
| SW1 | COMPLETE | 12/05/2013 | 12/06/2013 |
| ZON | HOLD | 12/05/2013 | 12/16/2013 |
| Note: 1. Please revise the site plan to show the dimensions of the proposed screen enclosure, as well as setbacks from the rear and side lot lines to the structure. 2. Please clarify on the site plan where on the existing covered lanai glass windows are to be added. 3. Please clarify whether any changes are being made to exterior stucco finishes as a result of new windows being added to the existing lanai. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 12/19/2013 |
| ELECTRIC FEE | ¤78.00 | 12/19/2013 |
| PLAN CHECK FEE | ¤40.00 | 12/19/2013 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 12/19/2013 |
| SITE PLAN 20 | ¤20.00 | 12/19/2013 |
| SURCHARGE FS 533.721 | ¤2.67 | 12/19/2013 |
| SURCHARGE - FS 468.631 | ¤2.67 | 12/19/2013 |
| STORM WATER PERMIT FEES | ¤80.00 | 12/19/2013 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤283.34 |