I want to search for...

Permit #2013120158

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00030-0040
CONDITIONED SPACE: 1760 sqft
GARAGE: 425 sqft
OPENED PORCH (WITH ROOF) : 190 sqft
PATIO/DECK (NO ROOF) : 193 sqft
Total Square Footage: 2568 sqft
Block: 00030
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: (386)254-5081
Location Address: 154 WELLSTONE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/21/2014
NOC: RECORDED
Applicant name: WAYNE LAWRENCE ADAMS
Owner: ADAMS HOMES OF NW FLORIDA

Address

3000 GULF BREEZE PWY

GULF BREEZE, FL 32563

Lot: 0040
Contracted Stated Job Value: ¤120,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ADAMS HOMES OF NW FLORIDA INC
Status Location Address State License Number Phone Fax
INACTIVE

1101 Gulf Breeze Parkway Suite 229

Gulf Breeze, FL 32561

CBC043518 (Exp: 08/31/2014) (386)254-5081 (386)252-8284

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/30/2014 FINAL APPROVED RMARVEL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 04/29/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/29/2014 3:07:32 PM INSTALL HOUSE NUMBERS/GROUT/SEAL TOILETS AT FLOOR/PROVIDE INSULATION CERT AT ATTIC ACCESS TRUSS
FINAL APRON (AFTER POUR/DRIVEWAY) 04/29/2014 APPROVED RGROSS
ROW FINAL 04/29/2014 APPROVED RGROSS
U -UTILITY RESIDENTIAL FINAL 04/29/2014 FINAL APPROVED DSPENCER
FINAL SURVEY (OFFICE USE ONLY) 04/28/2014 APPROVED JMCGOWEN
PRE-APRON (PRE-POUR/DRIVEWAY) 04/21/2014 APPROVED RGROSS
Note: THIS IS A REINSPECTION READY TO POUR
ELECTRIC - EARLY POWER 04/21/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 4/21/2014 3:05:02 PM CALLED FPL TO RELEASE POWER AT 2:15,SPOKE WITH KAREN
PRE-APRON (PRE-POUR/DRIVEWAY) 04/17/2014 Disapproved - NO FEE RGROSS
Note: THIS IS A REINSPECTION Apron Slope too steep.
PRE-APRON (PRE-POUR/DRIVEWAY) 04/16/2014 Disapproved -FEE REQUIRED GLALIMA
Note: SEE PINK PAINT NEED TO HAVE 36 " FLAIR S AT STREET .. CULVERT ENDS ARE TO BE 18'' . ALSO CHECK THAT YOU HAVE 6'' OF CONCRETE AT EDGE OF ROAD. SEE DRIVEWAY DETAIL SLOPE IS TO BE 8% OR LESS AT TIME OF INSPECTION 10 . 7 % .
GRAVITY SEWER TEST 04/16/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 04/11/2014 APPROVED DSPENCER
GRAVITY SEWER TEST 04/11/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/11/2014 3:11:11 PM PIPE MUST BE EXPOSED UN-COVER FOR VIEWING
INSULATION 03/18/2014 APPROVED RMARVEL
ALL ROUGH 03/14/2014 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 3/14/2014 3:15:41 PM MUST HAVE 5FT HEAD PRESSURE ON SANITARY LINES AT INSULATION.
LATH/BRICK/ WATER BARRIER 03/11/2014 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/11/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
FOUND SURVEY APPROVED (OFFICE) 03/05/2014 APPROVED JMCGOWEN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/05/2014 Disapproved -FEE REQUIRED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 3/5/2014 2:46:13 PM H2.5 AT EXTERIOR CORS ARE NOT INSTALLED TO MANUFACTURERS SPECIFICATIONS. THEY ARE FOLDED AT PREBENDS. MSTA20 AT HJ)@ RIGHT FRONT CORNER OF HOUSE HAS BEEN FLATTENED AT PREBEND. INSTALL TO MANUFACTURERS SPECIFICATIONS.
WALL SHEATHING 03/04/2014 APPROVED RMARVEL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/04/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 3/4/2014 1:32:18 PM WORK IN PROGRESS. NOT READY FOR INSPECTION. FBC 2010 105 WORK NEEDS TO BE COMPLETE BEFORE INSPECTION IS CALLED IN.
MONOLITHIC SLAB 02/12/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 02/11/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 2/11/2014 3:19:57 PM RELIEVING ARCH IN FOOTING P2603.5. AT PLUMBING ON LEFT SIDE.
PLUMBING 1ST ROUGH UNDERGROUND 02/07/2014 APPROVED RMARVEL
ELECTRIC TEMP POLE 01/30/2014 APPROVED RMARVEL
Note: Inspection Resulted at 1/30/2014 3:22:53 PM CALLED FPL AT 3:20

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/28/2014 04/28/2014
Note: Released By: JMCGOWEN final s
SW1 COMPLETE 03/05/2014 03/05/2014
Note: Released By: JMCGOWEN foundation survey
ENGIN1 COMPLETE 01/07/2014 01/08/2014
MECH COMPLETE 12/27/2013 12/27/2013
ENGIN1 HOLD 12/27/2013 12/30/2013
Note: Surveyor's unable to verify benchmark elevation. Check benchmark elevation.
ZON COMPLETE 12/27/2013 12/31/2013
BLD COMPLETE 12/06/2013 12/09/2013
ELEC COMPLETE 12/06/2013 12/09/2013
ENGIN1 HOLD 12/06/2013 12/09/2013
Note: Verify vertical datum. Scott Bombardier 986-3756
MECH HOLD 12/06/2013 12/09/2013
Note: Directional orientation of the building and its corresponding areas of the windows shown on energy calculations do not match with the orientation shown on site plan. Coordinate and submit correction per 2010 FBC EC 403.6.1.
PLUM COMPLETE 12/06/2013 12/09/2013
SW1 COMPLETE 12/06/2013 12/09/2013
UD1 COMPLETE 12/06/2013 12/09/2013
Note: See comments in the general notes Keith King 386-9318009
URB COMPLETE 12/06/2013 12/10/2013
ZON HOLD 12/06/2013 12/18/2013
Note: Revise site plan to show both flood map panel numbers.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 04/30/2014
REINSPECTION FEE ¤40.00 04/28/2014
REINSPECTION FEE ¤40.00 04/28/2014
REINSPECTION FEE ¤40.00 04/28/2014
REINSPECTION FEE ¤40.00 04/28/2014
REINSPECTION FEE ¤40.00 04/28/2014
NEW RESIDENTIAL INSPECTIONS ¤458.00 01/21/2014
SITE PLAN 20 ¤20.00 01/21/2014
SURCHARGE FS 533.721 ¤17.43 01/21/2014
SURCHARGE - FS 468.631 ¤17.43 01/21/2014
STORM WATER PERMIT FEES ¤80.00 01/21/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 01/21/2014
ADMIN FEE ¤20.00 01/21/2014
ELECTRIC FEE ¤197.40 01/21/2014
3% FIRE IMPACT FEE CREDIT (¤6.24) 01/21/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 01/21/2014
IMPACT FEE PARKS ¤1,343.98 01/21/2014
IMPACT FEE SCHOOL ¤3,600.00 01/21/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 01/21/2014
MECHANICAL FEE ¤197.40 01/21/2014
3% PARKS IMPACT FEE CREDIT (¤40.32) 01/21/2014
PLAN CHECK FEE ¤91.60 01/21/2014
PLUMBING FEE ¤197.40 01/21/2014
Fees Total Due: ¤0.00 Total Paid: ¤9,568.61