Permit #2013120159
Permit Details
Status: COED
| Parcel Id: 07-11-31-7029-00130-0130 |
| CONDITIONED SPACE: 2265 sqft |
| GARAGE: 479 sqft |
| OPENED PORCH (WITH ROOF) : 184 sqft |
| PATIO/DECK (NO ROOF) : 84 sqft |
| Total Square Footage: 3012 sqft |
| Block: 00130 |
| Subdivision: 2209 - SECTION 29-ROYAL PALMS |
| Job Phone: (386)254-5081 |
| Location Address: 56 RYECLIFFE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/10/2014 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES OF NORTHWEST FLORIDA INC |
|
Address 3000 GULF BREEZE PKWY GULF BREEZE, FL 32563 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤149,300.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2018) | (407)333-2665 | (407)585-1002 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
IAN MICHEAL JOHNSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4244 JACKSON STREET PORT ORANGE, FL 32127 |
CCC1325915 (Exp: 08/31/2026) | 386-760-0764 | 386-760-3080 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 05/15/2014 | APPROVED | RGROSS |
| ROW FINAL | 05/15/2014 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 05/15/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 05/14/2014 | FINAL APPROVED | DROCKWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 05/12/2014 | APPROVED | JHINDMAN |
| GRAVITY SEWER TEST | 05/08/2014 | APPROVED | DROCKWELL |
| U - SEWER TIE IN | 05/08/2014 | APPROVED | DSPENCER |
| ELECTRIC - EARLY POWER | 04/21/2014 | APPROVED | DROCKWELL |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/21/2014 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| INSULATION | 03/11/2014 | APPROVED | DROCKWELL |
| ALL ROUGH | 03/10/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 03/06/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/6/2014 3:11:06 PM A/C GAS LINES NOT INSTALLED-FILL CHASE WITH APPROPRIATE MATERIALS/MISSING 1 OUTLET ON PLANS (NOOK) REMEMBER-OUTLETS ON PLAN MUST BE INSTALLED PER PLAN. | |||
| LATH/BRICK/ WATER BARRIER | 03/04/2014 | APPROVED | DROCKWELL |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/27/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/21/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 2/21/2014 2:46:18 PM ROOF METALS ON BY THIS INSPECTION/STRAP 2X6 WHERE SUPPORTING ROOF SHEATHING/REMOVE SHINNERS IN SAME VALLEY | |||
| WALL SHEATHING | 02/19/2014 | APPROVED | DROCKWELL |
| FOUND SURVEY APPROVED (OFFICE) | 02/12/2014 | APPROVED | FREODICA |
| ELECTRIC TEMP POLE | 01/30/2014 | APPROVED | DROCKWELL |
| MONOLITHIC SLAB | 01/28/2014 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/24/2014 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/12/2014 | 05/12/2014 |
| Note: Released By: JHINDMAN final survey | |||
| SW1 | COMPLETE | 02/12/2014 | 02/12/2014 |
| Note: Released By: FREODICA foundation | |||
| ENGIN1 | COMPLETE | 12/20/2013 | 12/31/2013 |
| BLD | COMPLETE | 12/09/2013 | 12/09/2013 |
| ELEC | COMPLETE | 12/09/2013 | 12/09/2013 |
| ENGIN1 | HOLD | 12/09/2013 | 12/09/2013 |
| Note: Provide Benchmark Scott Bombardier 986-3756 | |||
| MECH | COMPLETE | 12/09/2013 | 12/09/2013 |
| PLUM | COMPLETE | 12/09/2013 | 12/09/2013 |
| SW1 | COMPLETE | 12/09/2013 | 12/09/2013 |
| UD1 | COMPLETE | 12/09/2013 | 12/09/2013 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 12/09/2013 | 12/10/2013 |
| ZON | COMPLETE | 12/09/2013 | 12/18/2013 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 04/21/2014 |
| REINSPECTION FEE | ¤40.00 | 04/21/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤564.00 | 01/10/2014 |
| SITE PLAN 20 | ¤20.00 | 01/10/2014 |
| SURCHARGE FS 533.721 | ¤20.77 | 01/10/2014 |
| SURCHARGE - FS 468.631 | ¤20.77 | 01/10/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/10/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 01/10/2014 |
| ADMIN FEE | ¤20.00 | 01/10/2014 |
| ELECTRIC FEE | ¤229.20 | 01/10/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 01/10/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 01/10/2014 |
| IMPACT FEE PARKS | ¤1,343.98 | 01/10/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/10/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 01/10/2014 |
| MECHANICAL FEE | ¤229.20 | 01/10/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 01/10/2014 |
| PLAN CHECK FEE | ¤112.80 | 01/10/2014 |
| PLUMBING FEE | ¤229.20 | 01/10/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,637.89 |