Permit #2013120583
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00550-0160 |
| CONDITIONED SPACE: 2508 sqft |
| GARAGE: 543 sqft |
| OPENED PORCH (WITH ROOF) : 193 sqft |
| OPENED PORCH (WITH ROOF) : 193 sqft |
| Total Square Footage: 3437 sqft |
| Block: 00550 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: (386)254-5081 |
| Location Address: 44 PINE BROOK DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/24/2014 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES OF NORTHWEST FLORIDA INC |
|
Address 3000 GULF BREEZE PARKWAY GULF BREEZE, FL 32563 |
| Lot: 0160 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2018) | (407)333-2665 | (407)585-1002 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
IAN MICHEAL JOHNSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4244 JACKSON STREET PORT ORANGE, FL 32127 |
CCC1325915 (Exp: 08/31/2026) | 386-760-0764 | 386-760-3080 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/08/2014 | FINAL APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 05/08/2014 | APPROVED | RGROSS |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 05/07/2014 | APPROVED | GLALIMA |
| ROW FINAL | 05/07/2014 | Disapproved - NO FEE | GLALIMA |
| Note: SPOKE WITH G.M ABOUT EROSION AND SOD AT CULVERT ENDS. NO FEE . | |||
| U -UTILITY RESIDENTIAL FINAL | 05/07/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 05/07/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 5/7/2014 3:22:25 PM PROVIDE A #6AWG CONDUCTOR FOR INTERSYSTEM BOND BAR TO MAIN GROUNDING TERMINAL.NEC 2008 250.94(2,3) IDENTIFY AHU MOCP. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/06/2014 | APPROVED | JHINDMAN |
| ELECTRIC - EARLY POWER | 04/24/2014 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/24/2014 3:03:49 PM CALLED FPL TO RELEASE POWER AT 3:00,SPOKE WITH SUSAN | |||
| ELECTRIC - EARLY POWER | 04/23/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 4/23/2014 3:36:08 PM SAFE OFF ALL ELECTRICAL CABLES. RIGHT FRONT SIDE OF HOUSE HAS NM CABLE HANGING OUT UNPROTECTED. | |||
| GRAVITY SEWER TEST | 04/21/2014 | APPROVED | CMINI |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/21/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 04/21/2014 | APPROVED | DSPENCER |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 04/16/2014 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: REMOVE CULVERT WITH HOLES . NEED TO MOVE RIGHT SIDE OF DRIVEWAY OVER OUT OF R.O.W . DRIVEWAY NEEDS TO BE FORMED AS PER '''APPROVED SURVEY '''. JUST TO LET YOU KNOW , YOUR CUTTING YOUR CULVERT TO LONG . ... CALL IF YOU NEED SITE MEET. | |||
| INSULATION | 03/17/2014 | APPROVED | DROCKWELL |
| ALL ROUGH | 03/17/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 03/13/2014 | APPROVED | DROCKWELL |
| ALL ROUGH | 03/13/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 3/13/2014 3:11:51 PM FAN/LIGHT COMBO``S IN ALL BATHS NOT WIRED/CAP GUEST SHOWER AND OPEN VALVE TO CHECK CONNECTIONS ABOVE VALVE | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/05/2014 | APPROVED | JMCGOWEN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/28/2014 | APPROVED | DROCKWELL |
| WALL SHEATHING | 02/26/2014 | APPROVED | DROCKWELL |
| MONOLITHIC SLAB | 02/13/2014 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/11/2014 | APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 05/06/2014 | 05/06/2014 |
| Note: Released By: JHINDMAN final survey | |||
| SW1 | COMPLETE | 03/05/2014 | 03/05/2014 |
| Note: Released By: JMCGOWEN foundation survey | |||
| ZON | COMPLETE | 03/05/2014 | 03/05/2014 |
| Note: Released By: JGONZALEZ | |||
| BLD | COMPLETE | 02/12/2014 | 02/13/2014 |
| ZON | COMPLETE | 02/12/2014 | 02/12/2014 |
| ELEC | COMPLETE | 01/14/2014 | 01/14/2014 |
| MECH | COMPLETE | 01/14/2014 | 01/14/2014 |
| UD1 | COMPLETE | 01/14/2014 | 01/14/2014 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| ZON | COMPLETE | 01/14/2014 | 01/14/2014 |
| BLD | COMPLETE | 12/30/2013 | 12/30/2013 |
| ELEC | HOLD | 12/30/2013 | 12/30/2013 |
| Note: Provide electrician’s license number and qualifier’s name on electric drawing FBC 107.1 | |||
| ENGIN1 | COMPLETE | 12/30/2013 | 01/02/2014 |
| MECH | HOLD | 12/30/2013 | 12/30/2013 |
| Note: Provide duct layout drawing FBC 107.2.1 | |||
| PLUM | COMPLETE | 12/30/2013 | 12/30/2013 |
| SW1 | COMPLETE | 12/30/2013 | 12/30/2013 |
| UD1 | HOLD | 12/30/2013 | 12/30/2013 |
| Note: pep panel must be shown on the lectrical plan. PEP Tank area, make sure the plumber knows where to exit the slab with the sewer pipe to match the utility marked site plan, we prefer to see the pipe exit on the side of the building the tank will be on to reduce piping under driveways or sidewalks and to minimize the fall needed. The Pep Panel should be placed within 3 feet from the front corner on the same side of building as the tank. The sewer tie-in inspection must be called in the day before the tie-in. The morning of the tie-in the inspector must be contacted to coordinate the time of the tie-in so he can witness the tie-in. All Concrete work must maintain at least 4.5” clear zone from all water meters or pep tank lids and 9 feet behind the pep tank lid. See comment in general notes Danny Spencer 386-569-9082 | |||
| URB | COMPLETE | 12/30/2013 | 12/31/2013 |
| ZON | HOLD | 12/30/2013 | 01/02/2014 |
| Note: Revise building, landscape and/ or site plan to show correect building layout. House is flipped. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/08/2014 |
| REINSPECTION FEE | ¤40.00 | 05/08/2014 |
| REINSPECTION FEE | ¤40.00 | 05/08/2014 |
| REINSPECTION FEE | ¤40.00 | 04/21/2014 |
| REINSPECTION FEE | ¤40.00 | 04/21/2014 |
| REINSPECTION FEE | (¤40.00) | 04/21/2014 |
| REINSPECTION FEE | ¤40.00 | 04/21/2014 |
| REINSPECTION FEE | (¤40.00) | 04/21/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤632.00 | 01/24/2014 |
| SITE PLAN 20 | ¤20.00 | 01/24/2014 |
| SURCHARGE FS 533.721 | ¤22.91 | 01/24/2014 |
| SURCHARGE - FS 468.631 | ¤22.91 | 01/24/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/24/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 01/24/2014 |
| ADMIN FEE | ¤20.00 | 01/24/2014 |
| ELECTRIC FEE | ¤249.60 | 01/24/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 01/24/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 01/24/2014 |
| IMPACT FEE PARKS | ¤1,343.98 | 01/24/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/24/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 01/24/2014 |
| MECHANICAL FEE | ¤249.60 | 01/24/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 01/24/2014 |
| PLAN CHECK FEE | ¤126.40 | 01/24/2014 |
| PLUMBING FEE | ¤249.60 | 01/24/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,864.97 |