Permit #2014010135
Permit Details
Status: FINAL
| Parcel Id: 27-11-31-0000-01010-0100 |
| CONDITIONED SPACE: 278 sqft |
| Total Square Footage: 278 sqft |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 386-437-4699 |
| Location Address: 20 GRANDVIEW DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 01/23/2014 |
| NOC: RECORDED |
| Applicant name: RICHARD JAMES SMITH |
| Owner: MCNAMARA, JOHN S & MARILYN L |
|
Address 20 GRANDVIEW DR PALM COAST, FL 32137 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤60,000.00 |
| Job Description: ADDITION ABOVE GARAGE ROOM/RENOVATION & ALTERATION |
| Type: CN |
Contractor
HAMMOCK COMMUNITIES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
725 NORTH OCEANSHORE BLVD FLAGLER BEACH, FL 32136 |
CGC1516033 (Exp: 08/31/2026) | 386-693-4947 |
Sub Contractors
ARTHUR J PASCOE
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 730007 ORMOND BEACH, FL 32174 |
ER13012583 (Exp: 08/31/2016) | (386)677-9419 | (386)615-0572 |
STEPHEN M RENDE
| Status | Location Address | State License Number | Phone |
| CANCEL |
22 ALAMANDA DRIVE ORMOND, FL 32176 |
CCC058058 (Exp: 08/31/2020) | 386-439-7156 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 09/15/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 04/28/2014 | FINAL APPROVED | CMINI |
| INSULATION | 03/18/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 03/18/2014 | APPROVED | CMINI |
| ALL ROUGH | 03/17/2014 | APPROVED | CMINI |
| ALL ROUGH | 03/14/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 03/14/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/14/2014 3:44:06 PM ADD REQUIRED FIRE BLOCKING AT GARAGE TO ROOM ABOVE PER FRC 2010 302.5,302.6, 302.11. | |||
| INSULATION | 03/06/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 3/6/2014 2:56:11 PM NOT READY FOR INSULATION INSPECTION..ALL ROUGH NEEDS TO BE PASSED,WINDOWS NEED TO BE INSTALLED ALL PENATRATIONS NEED TO BE FIRE FOAMED OR FIRECAUALKED BEFORE DRYWALL CAN BE INSTALLED. | |||
| ALL ROUGH | 02/28/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 2/28/2014 2:45:46 PM WINDOWS AND SHINGLES NEEDS TO BE INSTALLED AT THIS INSPECTION...NEED TO SHOW ON PLAN AIR DUCTS ADDED TO ADDITION AND NEED TO SHOW ON PLAN ELECTRIC WORK ADDED TO GARAGE CEILING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/21/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| WALL SHEATHING | 02/21/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/20/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 2/20/2014 3:01:24 PM COMPLETE SHOE PLATE LAG BOLTING INTO FLOOR TRUSSES AS PER PLAN/MISSING SIMPSON H8 TIE-DOWNS AT GABLE TRUSS CENTERS AS PER PLAN/STRAPS AT HEADERS TO OVERLAP TOP PLATE AS PER PLAN 18IN EACH SIDE. | |||
| WALL SHEATHING | 02/20/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 2/20/2014 3:01:25 PM FASTENERS ARE OVER SUNK MANY AREAS CANNOT EXCEED 1/8 IN.RE-NAIL WITH PROPER PRESSURE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/12/2014 | 03/13/2014 |
| ELEC | COMPLETE | 03/10/2014 | 03/12/2014 |
| MECH | HOLD | 03/10/2014 | 03/11/2014 |
| Note: Provide supply air duct sizes, source connection and clarify how return air to hvac would be accomplished per 2010 FBC 104.2.1. | |||
| MECH | COMPLETE | 01/15/2014 | 01/15/2014 |
| MECH | HOLD | 01/14/2014 | 01/14/2014 |
| Note: Provide energy calculation of the proposed enlarge upper room and the capacity of existing hvac unit serving that proposed room to determine if it can handle the additional load per 2010 FBC 2010 FBC 107.2.1. | |||
| BLD | COMPLETE | 01/08/2014 | 01/08/2014 |
| ELEC | COMPLETE | 01/08/2014 | 01/08/2014 |
| MECH | HOLD | 01/08/2014 | 01/08/2014 |
| Note: Provide energy calculation of the proposed enlarge upper room and the capacity of existing hvac unit serving that proposed room to determine if it can handle the additional load per 2010 FBC 2010 FBC 107.2.1. | |||
| PLUM | COMPLETE | 01/08/2014 | 01/08/2014 |
| Note: NA | |||
| SW1 | COMPLETE | 01/08/2014 | 01/08/2014 |
| ZON | COMPLETE | 01/08/2014 | 01/13/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 03/16/2014 |
| REVISION | ¤40.00 | 03/16/2014 |
| REINSPECTION FEE | ¤40.00 | 03/16/2014 |
| REINSPECTION FEE | ¤40.00 | 03/16/2014 |
| REINSPECTION FEE | ¤40.00 | 03/05/2014 |
| REINSPECTION FEE | ¤40.00 | 02/20/2014 |
| REINSPECTION FEE | ¤40.00 | 02/20/2014 |
| ADMIN FEE | ¤20.00 | 01/23/2014 |
| ELECTRIC FEE | ¤96.00 | 01/23/2014 |
| PLAN CHECK FEE | ¤40.00 | 01/23/2014 |
| SITE PLAN 20 | ¤20.00 | 01/23/2014 |
| SURCHARGE FS 533.721 | ¤2.94 | 01/23/2014 |
| SURCHARGE - FS 468.631 | ¤2.94 | 01/23/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/23/2014 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 01/23/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤581.88 |