I want to search for...

Permit #2014010142

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-1260
CONDITIONED SPACE: 2351 sqft
GARAGE: 489 sqft
OPENED PORCH (WITH ROOF) : 168 sqft
OPENED PORCH (WITH ROOF) : 56 sqft
Total Square Footage: 3064 sqft
Block: 01010
Subdivision: 2094 - Conservatory at Hammock Beach
Job Phone: (386)383-0376
Location Address: 602 MAHOGANY RUN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/30/2014
NOC: RECORDED
Applicant name: ANTHONY CRAIG GUCCIONE
Owner: WILLIAM KINSMAN

Address

567 MEADOW ROAD

TOPSHAM, MA 04086

Lot: 126
Contracted Stated Job Value: ¤297,500.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLD COAST HOME BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 354707

PALM COAST, FL 32137

CGC1507791 (Exp: 08/31/2026) 386-313-6221

Sub Contractors

MARK WILLIAM SCHOUTEN
Status Location Address State License Number Phone Fax
CANCEL

140 E LAKE AVE

LONGWOOD, FL 32750

CCC1330043 (Exp: 08/31/2016) 407-260-2304 407-260-1883
BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 02/16/2015 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 02/03/2015 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 01/30/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 1/30/2015 2:45:16 PM LIGHTING OUTLETS SHALL BE INSTALLED IN BED ROOMS. NEED LIGHT SOURCE IN BEDROOM. NEC 210.70....GFI ON OUTLET COVERS IN KITCHEN,.....HVAC HOOD VENT NEEDS TO BE CONNECTED.... PLUG HOLE IN ELCTRICAL CONDUIT IN GARAGE. REMOVE PALLETS OF ROOF TILE FORM ADJACENT LOT.
FINAL APRON (AFTER POUR/DRIVEWAY) 01/14/2015 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
ROW FINAL 01/14/2015 APPROVED - AS NOTED GLALIMA
Note: PICK UP THE LITTLE TRASH NEXT DOOR VACANT LOT ON RIGHT AND REMOVE ROOF TITLES . WILL DO RIDE BY . SEED AND STRAW
FINAL SURVEY (OFFICE USE ONLY) 01/12/2015 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 01/06/2015 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 1/6/2015 10:41:01 AM CALLED FPL TO RELEASE POWER AT 10:15, SPOKE WITH DELL
U - SEWER TIE IN 11/25/2014 APPROVED DSPENCER
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 11/24/2014 CANCELLED BY APPLICANT DSPENCER
FINAL APRON (AFTER POUR/DRIVEWAY) 11/20/2014 CANCELLED BY APPLICANT GLALIMA
Note: PER CONTRACTOR CALLED BUILDING AND GARY
PRE-APRON (PRE-POUR/DRIVEWAY) 11/18/2014 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION IF THE SURVEY / DRIVEWAY DETAIL AND PERMIT PACKAGE IS NOT IN PERMIT BOX IT WILL FAIL WITH A FEE .
PRE-APRON (PRE-POUR/DRIVEWAY) 11/14/2014 PARTIALLY APPROVED GLALIMA
Note: THIS IS A REINSPECTION WORKING ON NEW SURVEY . PAVERS
FINAL APRON (AFTER POUR/DRIVEWAY) 11/13/2014 CANCELLED BY APPLICANT AIRS WEB
Note: PER CONTRACTOR
PRE-APRON (PRE-POUR/DRIVEWAY) 11/13/2014 Disapproved -FEE REQUIRED GLALIMA
Note: SURVEY / DRIVEWAY DETAIL SHOW '' CONCRETE '' DRIVEWAY '' NOT '' PAVERS . I CALLED ZONING . NEW DETAIL NEEDED AND REINSPECTION A FEE HAS BEEN ADDED BECAUSE SURVRY / DRIVEWAY DETAIL DID SHOW A CONCRETE DRIVEWAY AND NO REVISION WAS IN PLACE .
LATH/BRICK/ WATER BARRIER 07/14/2014 APPROVED CMINI
INSULATION 07/11/2014 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 07/10/2014 CANCELLED BY APPLICANT CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2014 CANCELLED BY APPLICANT AIRS WEB
ALL ROUGH 06/27/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 06/20/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/20/2014 2:47:12 PM STRAP DRYER VENT EVERY 4 FBC.M1502.4.2 AND NAIL PLATE AT TOP..FIRE BLOCKING ..FBC 302.11 ....5`` HEAD ON DWV..FBC 2503.5.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/20/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/11/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/11/2014 3:23:57 PM TOWER TRUSSES CALLING FOR H10A,NEED CORRECTION..NEED DETAIL FOR THREADED RODS...NAIL BUCKETS IN GARAGE...HETAS CALLING FOR 10 10D NAILS IN ALL STRAPS..CHECK MISSING BRACING..REMOVE SHINERS IN GARAGE,CHECK ALL..NOT READY
TIE BEAM / LINTEL 04/08/2014 APPROVED RMARVEL
TIE BEAM / LINTEL 04/07/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 4/7/2014 12:03:30 PM UFER GROUND CANNOT BE POURED SOLID CELL. MOVE DOWEL TO MEET NEC 2008 250.
FOUND SURVEY APPROVED (OFFICE) 04/02/2014 APPROVED JMCGOWEN
ELECTRIC-TUG 04/02/2014 APPROVED RMARVEL
Note: Inspection Resulted at 4/2/2014 3:48:34 PM CALLED FPL AT 1:20
MONOLITHIC SLAB 03/06/2014 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 03/03/2014 APPROVED RMARVEL
GRAVITY SEWER TEST 03/03/2014 APPROVED RMARVEL

Review History

Department Status Date In Date Out
URB COMPLETE 02/10/2015 02/11/2015
URB HOLD 02/02/2015 02/04/2015
Note: Need to add 1 shade and 2 understory trees 2" @ 6" 8' in height 30 gallon container size. 4 of the street trees receive no credit towards the trees required on the property. per the PUD street tree agreement this sq. ft. is 12.060.68 sq. ft. requires 5 total trees 2 shade and 3 understory. the saved bald cypress is not on this property and receives no credit.
BLD COMPLETE 01/12/2015 01/13/2015
SW1 COMPLETE 01/09/2015 01/12/2015
Note: Released By: JHINDMAN FINAL S
BLD COMPLETE 11/13/2014 11/14/2014
ENGIN1 COMPLETE 11/13/2014 11/13/2014
Note: No swale plan requied.
ZON COMPLETE 11/13/2014 11/13/2014
BLD COMPLETE 06/16/2014 06/16/2014
BLD COMPLETE 06/09/2014 06/09/2014
SW1 COMPLETE 04/01/2014 04/02/2014
Note: Released By: JMCGOWEN foundation survey
ZON COMPLETE 01/23/2014 01/23/2014
ELEC COMPLETE 01/23/2014 01/23/2014
ELEC HOLD 01/16/2014 01/17/2014
Note: Locate receptacles to meet NEC 210.52
PLUM COMPLETE 01/16/2014 01/17/2014
ZON HOLD 01/16/2014 01/16/2014
Note: 1. Correct survey to remove the word easement from the 10 foot typical setback line. Change setback typical line so that it does not represent an easement. 2. Subdivision construction plans show a sidewalk to be constructed on each lot. Please provide for sidewalk on site plan. If sidewalks are intened to be built at another time with an approval from the City please provide a statement on plan. CB
BLD COMPLETE 01/08/2014 01/10/2014
ELEC HOLD 01/08/2014 01/08/2014
Note: Revise receptacle locations to meet NEC 210.52
ENGIN1 COMPLETE 01/08/2014 01/08/2014
Note: No swale plan required.
MECH COMPLETE 01/08/2014 01/09/2014
PLUM HOLD 01/08/2014 01/09/2014
Note: Provide plumbing riser detail FBC 107.2.1
SW1 COMPLETE 01/08/2014 01/08/2014
UD1 COMPLETE 01/08/2014 01/09/2014
Note: See comments in the general notes Keith King 386-9318009
URB COMPLETE 01/08/2014 01/10/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADDITIONAL FEE ¤40.00 02/17/2015
REVISION ¤40.00 02/17/2015
REVISION ¤40.00 02/17/2015
REVISION ¤40.00 02/17/2015
REINSPECTION FEE ¤40.00 02/17/2015
REINSPECTION FEE ¤40.00 02/17/2015
REINSPECTION FEE ¤40.00 02/17/2015
REINSPECTION FEE ¤40.00 02/17/2015
REINSPECTION FEE ¤40.00 02/17/2015
ADDITIONAL FEE ¤40.00 02/28/2014
NEW RESIDENTIAL INSPECTIONS ¤596.00 01/30/2014
SITE PLAN 20 ¤20.00 01/30/2014
SURCHARGE FS 533.721 ¤21.77 01/30/2014
SURCHARGE - FS 468.631 ¤21.77 01/30/2014
STORM WATER PERMIT FEES ¤80.00 01/30/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 01/30/2014
ADMIN FEE ¤20.00 01/30/2014
ELECTRIC FEE ¤238.80 01/30/2014
3% FIRE IMPACT FEE CREDIT (¤6.24) 01/30/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 01/30/2014
IMPACT FEE PARKS ¤1,343.98 01/30/2014
IMPACT FEE SCHOOL ¤3,600.00 01/30/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 01/30/2014
MECHANICAL FEE ¤238.80 01/30/2014
3% PARKS IMPACT FEE CREDIT (¤40.32) 01/30/2014
PLAN CHECK FEE ¤119.20 01/30/2014
PLUMBING FEE ¤238.80 01/30/2014
Fees Total Due: ¤0.00 Total Paid: ¤10,027.09