I want to search for...
Permit #2014010591
Permit Details
Status: COED
| Parcel Id: 15-11-31-2970-00000-0340 |
| CONDITIONED SPACE: 2725 sqft |
| GARAGE: 779 sqft |
| OPENED PORCH (WITH ROOF) : 513 sqft |
| OPENED PORCH (WITH ROOF) : 111 sqft |
| Total Square Footage: 4128 sqft |
| Block: 00000 |
| Subdivision: 2070 - Grand Haven North Phase 1 @ Grand Haven |
| Job Phone: 386-947-4481 |
| Location Address: 1 WATERVIEW DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/05/2014 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: JACKOWSKI, EDWARD M & LORRAINE B |
|
Address 2538 RIO PALERMO COURT PUNTA GORDA, FL 33950 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤375,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 08/22/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 08/21/2014 | FINAL APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 08/20/2014 | CANCELLED BY APPLICANT | DROCKWELL |
| BLD - BUILDING FINAL | 08/19/2014 | Disapproved - NO FEE | CMINI |
| Note: Inspection Resulted at 8/19/2014 3:22:13 PM EXPANSION TANK NEEDED ON WATER HEATER FBC..M2003...NEED TO CORRECT DRAINAGE FLOW ON RIGHT AND LEFT SIDES OF HOUSE,NEED TO CREATE SLIGHT SWALE SO WATER DOES NOT FLOW ON TO NEIGHBORING PROPERTIES | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 08/19/2014 | APPROVED | RGROSS |
| ROW FINAL | 08/19/2014 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 08/12/2014 | APPROVED | JHINDMAN |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/23/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/15/2014 | PARTIALLY APPROVED | GLALIMA |
| Note: PRE POUR APRON . REMOVE WATER WILL DO RIDE BY | |||
| ELECTRIC - EARLY POWER | 07/15/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 7/15/2014 11:25:21 AM CALLD FPL TO RELEASE POWER AT 11:00,SPOKE WITH SUSAN | |||
| INSULATION | 05/29/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 05/28/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 5/28/2014 3:21:25 PM FIREBLOCK ACROSS TOP OF SLIDER WHERE LEADS TO OPEN ATTIC SPACE...FIRE FOAM NEEDED IN MASTER BATH ABOVE ARCH AREA LEADING TO ATTIC AND AT PANEL NOT COMPLETELY FIREFOAMED PENATRATIONS | |||
| ALL ROUGH | 05/15/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 05/09/2014 | APPROVED | RMARVEL |
| ALL ROUGH | 05/09/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 5/9/2014 4:13:27 PM STRAP NM CABLE EVERY 4.5FT. DO NOT STRAP TO ANOTHER CABLE OR RACEWAY. RECHECK FOR NAIL PLATES. MISSING RECEPTACLES AND LIGHTS PER APPROVED PLANS. WHITE CONDUCTORS ARE DENOTED AS NEUTRAL CONDUCTORSPER 2008 NEC, IDENIFY ALL WHITE CONDUCTORS BEING USED AS HOTS AS SUCH. WALL AT KITCHEN HAS STUDS SPACED OVER 26IN. INSTALL TO APPROVED PLANS. FOR ALLOR PROVIDE REVISION. INSPECTION STOPPED. INCOMPLETE. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/01/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/29/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 4/29/2014 2:42:27 PM MISSING THREADED RODS PER PLAN...MISSING DOUBLE 2X UNDER HIP WITH HTT TIE DOWN IN 1ST BD.RM..MISSING STRAPS AND ANCHOR BOLTS AT FRONT ENTRY WALLS OVER BLOCK WALLS..STRAP AT JACKS IN GARAGE..VALLEY STRAP IN MASTER BATH.. | |||
| ELECTRIC-TUG | 04/08/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/8/2014 3:07:03 PM CALLED FPL AT 2:20 TO RELEASE POWER ,SPOKE WITH SUSAN | |||
| GRAVITY SEWER TEST | 03/26/2014 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 03/25/2014 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 03/24/2014 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 03/07/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 03/05/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 3/5/2014 3:22:19 PM AT REAR FOOTER (J), PLANS ARE NOT SHOWING A JOGGED CORNER...AND PLANS ARE SHOWING(J) FOOTER AS A MONO SLAB..ALSO DETAILS (D)(M)(C) ARE SHOWING A BELL FOOTER ON BOTH SIDES OF SLAB. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/28/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/27/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 2/27/2014 3:01:13 PM 5`` HEAD REQUIRED ON DWV PLUMBERS STILL FILLING PIPE FBC 312 | |||
| U - SEWER TIE IN | 02/27/2014 | APPROVED | DSPENCER |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/12/2014 | 08/12/2014 |
| Note: Released By: JHINDMAN final survey | |||
| ELEC | COMPLETE | 05/14/2014 | 05/14/2014 |
| SW1 | COMPLETE | 03/24/2014 | 03/24/2014 |
| Note: Released By: FREODICA foundation survey | |||
| BLD | COMPLETE | 03/19/2014 | 03/19/2014 |
| BLD | COMPLETE | 03/17/2014 | 03/17/2014 |
| Note: no new floorplan to review | |||
| ZON | COMPLETE | 03/17/2014 | 03/17/2014 |
| BLD | COMPLETE | 03/05/2014 | 03/06/2014 |
| ZON | COMPLETE | 03/05/2014 | 03/06/2014 |
| PLUM | COMPLETE | 02/05/2014 | 02/05/2014 |
| MECH | COMPLETE | 02/05/2014 | 02/05/2014 |
| Note: No private provider for inspections per Sharon of Olsen Custom Homes. | |||
| PLUM | HOLD | 01/31/2014 | 01/31/2014 |
| Note: Shower is missing on sanitary riser diagram. Coordinate with floor plan and submit correction for clarity per 2010 FBC 107.2.1. | |||
| MECH | HOLD | 01/31/2014 | 01/31/2014 |
| Note: Previous comment item 1 shall be addressed - 1. Directional orientation of the building shown on energy calculations does not match with site plan. Coordinate and submit correction per 2010 FBCEC 403.6.1. Additional comment - Clarify if private provider will be doing the inspections and if there is, provide the required documentations per 2010 FBC 107.2.1. | |||
| BLD | COMPLETE | 01/31/2014 | 01/31/2014 |
| ZON | COMPLETE | 01/31/2014 | 02/03/2014 |
| BLD | HOLD | 01/24/2014 | 01/27/2014 |
| Note: Provide roof work sheet to include Florida product approval numbers FBC 107.2.1 | |||
| ELEC | COMPLETE | 01/24/2014 | 01/24/2014 |
| ENGIN1 | COMPLETE | 01/24/2014 | 01/24/2014 |
| Note: No swale plan required. | |||
| MECH | HOLD | 01/24/2014 | 01/27/2014 |
| Note: 1. Directional orientation of the building shown on energy calculations does not match with site plan. Coordinate and submit correction per 2010 FBCEC 403.6.1. 2. Provide manufacturer performance data of selected hvac units on sensible and total cooling capcities at the design conditions per 2010 FBCEC 403.6.1. | |||
| PLUM | HOLD | 01/24/2014 | 01/27/2014 |
| Note: Provide sanitary riser diagram per 20110 FBC 107.2.1. | |||
| SW1 | COMPLETE | 01/24/2014 | 01/24/2014 |
| UD1 | COMPLETE | 01/24/2014 | 01/27/2014 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 01/24/2014 | 01/27/2014 |
| ZON | HOLD | 01/24/2014 | 01/27/2014 |
| Note: 1. Structure as submitted does not meet minimum 10' rear yard setback. 2. Rear of property is facing golf course. Articulation, such as either horizontal banding or banding around doors and windows, is required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 09/16/2014 |
| REVISION | ¤40.00 | 09/16/2014 |
| REVISION | ¤40.00 | 09/16/2014 |
| REINSPECTION FEE | ¤40.00 | 09/16/2014 |
| REINSPECTION FEE | ¤40.00 | 09/16/2014 |
| REINSPECTION FEE | ¤40.00 | 09/16/2014 |
| REINSPECTION FEE | ¤40.00 | 09/16/2014 |
| REINSPECTION FEE | ¤40.00 | 09/16/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤750.00 | 02/05/2014 |
| SITE PLAN 20 | ¤20.00 | 02/05/2014 |
| SURCHARGE FS 533.721 | ¤26.63 | 02/05/2014 |
| SURCHARGE - FS 468.631 | ¤26.63 | 02/05/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/05/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 02/05/2014 |
| ADMIN FEE | ¤20.00 | 02/05/2014 |
| ELECTRIC FEE | ¤285.00 | 02/05/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 02/05/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 02/05/2014 |
| IMPACT FEE PARKS | ¤1,343.98 | 02/05/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/05/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 02/05/2014 |
| MECHANICAL FEE | ¤285.00 | 02/05/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 02/05/2014 |
| PLAN CHECK FEE | ¤150.00 | 02/05/2014 |
| PLUMBING FEE | ¤285.00 | 02/05/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,280.21 |