I want to search for...

Permit #2014010666

Permit Details

Status: COED

Parcel Id: 07-11-31-7058-00520-0120
CONDITIONED SPACE: 2464 sqft
GARAGE: 560 sqft
SCREEN PORCH (SOLID ROOF) : 142 sqft
OPENED PORCH (WITH ROOF) : 28 sqft
Total Square Footage: 3194 sqft
Block: 00520
Subdivision: 2215 - SECTION 58-SEMINOLE PARK
Job Phone: (904)296-1490
Location Address: 7 SEDAN PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/13/2014
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC 9700 PHILLIPS HWY

Address

9700 PHILIPS HWY

JACKSONVILLE, FL 32256

Address

SUITE 102

JACKSONVILLE, FL 32256

Lot: 0120
Contracted Stated Job Value: ¤129,750.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/19/2014 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 06/18/2014 FINAL APPROVED DROCKWELL
BLD - BUILDING FINAL 06/17/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/17/2014 1:52:50 PM MANY OUTLETS LOOSE-CHECK ALL/SHOWER DRAIN COVER MISSING/TRIM MISSING AT HAND-HELD SHOWER
BLD - BUILDING FINAL 06/16/2014 CANCELLED BY APPLICANT AIRS WEB
FINAL APRON (AFTER POUR/DRIVEWAY) 06/16/2014 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 06/16/2014 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 06/12/2014 CANCELLED BY APPLICANT GLALIMA
FINAL APRON (AFTER POUR/DRIVEWAY) 06/12/2014 CANCELLED BY APPLICANT GLALIMA
FINAL SURVEY (OFFICE USE ONLY) 06/11/2014 APPROVED JHINDMAN
TUB SET 06/09/2014 APPROVED DROCKWELL
ELECTRIC - EARLY POWER 06/09/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ELECTRIC - EARLY POWER 06/06/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/6/2014 3:10:41 PM PANEL COVER MISSING
ELECTRIC - EARLY POWER 06/05/2014 CANCELLED BY APPLICANT DROCKWELL
PRE-APRON (PRE-POUR/DRIVEWAY) 05/28/2014 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
PRE-APRON (PRE-POUR/DRIVEWAY) 05/27/2014 Disapproved -FEE REQUIRED GLALIMA
Note: TOOK PHOTO OF INSIDE JOB BOX COULD NOT FINED SWALE SHEET , TO CHECK ELEVATIONS . ALSO CHECK YOUR CLAMP . RE-INSPECTION NEEDED
U - SEWER TIE IN 05/13/2014 APPROVED DSPENCER
INSULATION 05/06/2014 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 5/6/2014 2:47:29 PM TONY, YOU WILL NEED TO CALL IN A TUB SET INSPECTION WHEN DROP-IN TUB IS SET AND PLUMBED.LEAVE DRYWALL OFF BACK WALL IN ADJACENT BEDROOM FOR INSPECTION.
INSULATION 05/02/2014 CANCELLED BY APPLICANT DROCKWELL
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 05/02/2014 APPROVED DROCKWELL
INSULATION 04/30/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/30/2014 2:58:41 PM HOUSE IS NOT DRIED IN. 6 ROOF VENTS MISSING.INSULATION AND STACKED DRYWALL IN HOUSE IN DANGER OF GETTING WET. IF INSULATION OR DRYWALL GETS WET YOU WILL BE REQUIRED TO REMOVE AND REPLACE.FOR FUTURE REFERNCE NEVER INSULATE UNTIL HOUSE IS COMPLETELY DRY.
ALL ROUGH 04/28/2014 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 4/28/2014 2:45:27 PM FILL FLOOR BOX UNDER SHOWER WITH APPROPRIATE MATERIAL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/24/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ALL ROUGH 04/24/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 4/24/2014 2:54:15 PM NM CABLE WRAPPED UNDER TRUSS AT LEFT FRONT OF HOUSE. RECHECK NAIL PLATES. MISSING IN MULTIPLE LOCATIONS. STRAP NM CABLE WITHIN 12IN OF ENCLOSURE AND EVERY 4.5FT. BEING SUPPORTED BY OTHER CABLES OR DUCTS ARE NOT ALLOWED. MULTIPLE LOCATIONS. MISSING RECEPTACLEIN BEDROOM BY DOOR PER APPROVED PLANS AND NEC 2008. RECEPTACLES ARE REQUIRED TO BE WITHIN 6FT OF OPENINGS. PANCAKE BOXES FOR COACH LIGHTS REQUIRE BUSHINGS OR CONNECTORS FOR CABLES. INSPECTION STOPPED. HAVE ELECTRICAL CONTRACTOR CHECK FOR CODE COMPLIANCE AND APPROVED PLAN REQUIREMENTS BEFORE NEXT INSPECTION.CABLES NOT USED AS MEANS OF SUPPORT.300.11(2)C. WALL SPACE...210.52A1. NAIL PLATES ON ELECTRIC NEC.300.4 STRAPPING OF ROMEX NEC.334.30. REQUIRED OUTLETS AND SPACING OF OUTLETS. NEC 2008 210.52
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/23/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 4/23/2014 3:36:07 PM LOOSE SHEATHING FRONT LEFT OF HOUSE.(CIRCLED ON PLANS). MISSING TRUSS ENGINEERING ON TRUSS 12. LEFT PAGE OPENON TRUSS AND CIRCLED MISSING PIECE.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/21/2014 CANCELLED BY APPLICANT AIRS WEB
TIE BEAM / LINTEL 04/01/2014 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 03/19/2014 APPROVED JHINDMAN
MONOLITHIC SLAB 03/19/2014 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2014 APPROVED DROCKWELL
GRAVITY SEWER TEST 03/14/2014 APPROVED DROCKWELL
STEM WALL FOUNDATION 03/11/2014 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 06/11/2014 06/11/2014
Note: Released By: JHINDMAN FINAL SURVEY
SW1 COMPLETE 03/19/2014 03/19/2014
Note: Released By: JHINDMAN
URB COMPLETE 01/29/2014 01/30/2014
BLD COMPLETE 01/28/2014 01/28/2014
ELEC COMPLETE 01/28/2014 01/28/2014
ENGIN1 COMPLETE 01/28/2014 01/29/2014
MECH COMPLETE 01/28/2014 01/28/2014
PLUM COMPLETE 01/28/2014 01/28/2014
SW1 COMPLETE 01/28/2014 01/28/2014
UD1 COMPLETE 01/28/2014 01/30/2014
URB HOLD 01/28/2014 01/29/2014
Note: Need to submit a landscape plan
ZON COMPLETE 01/28/2014 01/29/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/20/2014
REINSPECTION FEE ¤40.00 06/20/2014
REINSPECTION FEE ¤40.00 06/20/2014
REINSPECTION FEE ¤40.00 06/20/2014
REINSPECTION FEE ¤40.00 06/20/2014
REINSPECTION FEE ¤40.00 06/20/2014
NEW RESIDENTIAL INSPECTIONS ¤606.00 02/13/2014
SITE PLAN 20 ¤20.00 02/13/2014
SURCHARGE FS 533.721 ¤22.09 02/13/2014
SURCHARGE - FS 468.631 ¤22.09 02/13/2014
STORM WATER PERMIT FEES ¤80.00 02/13/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 02/13/2014
ADMIN FEE ¤20.00 02/13/2014
ELECTRIC FEE ¤241.80 02/13/2014
3% FIRE IMPACT FEE CREDIT (¤6.24) 02/13/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 02/13/2014
IMPACT FEE PARKS ¤1,343.98 02/13/2014
IMPACT FEE SCHOOL ¤3,600.00 02/13/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 02/13/2014
MECHANICAL FEE ¤241.80 02/13/2014
3% PARKS IMPACT FEE CREDIT (¤40.32) 02/13/2014
PLAN CHECK FEE ¤121.20 02/13/2014
PLUMBING FEE ¤241.80 02/13/2014
Fees Total Due: ¤0.00 Total Paid: ¤9,888.73