I want to search for...
Permit #2014010666
Permit Details
Status: COED
| Parcel Id: 07-11-31-7058-00520-0120 |
| CONDITIONED SPACE: 2464 sqft |
| GARAGE: 560 sqft |
| SCREEN PORCH (SOLID ROOF) : 142 sqft |
| OPENED PORCH (WITH ROOF) : 28 sqft |
| Total Square Footage: 3194 sqft |
| Block: 00520 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: (904)296-1490 |
| Location Address: 7 SEDAN PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/13/2014 |
| NOC: RECORDED |
| Applicant name: KENNETH WAYNE CAMPBELL JR |
| Owner: MARONDA HOMES INC 9700 PHILLIPS HWY |
|
Address 9700 PHILIPS HWY JACKSONVILLE, FL 32256 |
|
Address SUITE 102 JACKSONVILLE, FL 32256 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤129,750.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. OF FLORIDA
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6800 SOUTHPOINT PKWAY SUITE 300 JACKSONVILLE, FL 32216 |
CBC058803 (Exp: 08/31/2018) | 904-268-7730 | 904-268-7740 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2018) | (407)333-2665 | (407)585-1002 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 06/19/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 06/18/2014 | FINAL APPROVED | DROCKWELL |
| BLD - BUILDING FINAL | 06/17/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 6/17/2014 1:52:50 PM MANY OUTLETS LOOSE-CHECK ALL/SHOWER DRAIN COVER MISSING/TRIM MISSING AT HAND-HELD SHOWER | |||
| BLD - BUILDING FINAL | 06/16/2014 | CANCELLED BY APPLICANT | AIRS WEB |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/16/2014 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 06/16/2014 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 06/12/2014 | CANCELLED BY APPLICANT | GLALIMA |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 06/12/2014 | CANCELLED BY APPLICANT | GLALIMA |
| FINAL SURVEY (OFFICE USE ONLY) | 06/11/2014 | APPROVED | JHINDMAN |
| TUB SET | 06/09/2014 | APPROVED | DROCKWELL |
| ELECTRIC - EARLY POWER | 06/09/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC - EARLY POWER | 06/06/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 6/6/2014 3:10:41 PM PANEL COVER MISSING | |||
| ELECTRIC - EARLY POWER | 06/05/2014 | CANCELLED BY APPLICANT | DROCKWELL |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 05/28/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 05/27/2014 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: TOOK PHOTO OF INSIDE JOB BOX COULD NOT FINED SWALE SHEET , TO CHECK ELEVATIONS . ALSO CHECK YOUR CLAMP . RE-INSPECTION NEEDED | |||
| U - SEWER TIE IN | 05/13/2014 | APPROVED | DSPENCER |
| INSULATION | 05/06/2014 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/6/2014 2:47:29 PM TONY, YOU WILL NEED TO CALL IN A TUB SET INSPECTION WHEN DROP-IN TUB IS SET AND PLUMBED.LEAVE DRYWALL OFF BACK WALL IN ADJACENT BEDROOM FOR INSPECTION. | |||
| INSULATION | 05/02/2014 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 05/02/2014 | APPROVED | DROCKWELL |
| INSULATION | 04/30/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 4/30/2014 2:58:41 PM HOUSE IS NOT DRIED IN. 6 ROOF VENTS MISSING.INSULATION AND STACKED DRYWALL IN HOUSE IN DANGER OF GETTING WET. IF INSULATION OR DRYWALL GETS WET YOU WILL BE REQUIRED TO REMOVE AND REPLACE.FOR FUTURE REFERNCE NEVER INSULATE UNTIL HOUSE IS COMPLETELY DRY. | |||
| ALL ROUGH | 04/28/2014 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/28/2014 2:45:27 PM FILL FLOOR BOX UNDER SHOWER WITH APPROPRIATE MATERIAL | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/24/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 04/24/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 4/24/2014 2:54:15 PM NM CABLE WRAPPED UNDER TRUSS AT LEFT FRONT OF HOUSE. RECHECK NAIL PLATES. MISSING IN MULTIPLE LOCATIONS. STRAP NM CABLE WITHIN 12IN OF ENCLOSURE AND EVERY 4.5FT. BEING SUPPORTED BY OTHER CABLES OR DUCTS ARE NOT ALLOWED. MULTIPLE LOCATIONS. MISSING RECEPTACLEIN BEDROOM BY DOOR PER APPROVED PLANS AND NEC 2008. RECEPTACLES ARE REQUIRED TO BE WITHIN 6FT OF OPENINGS. PANCAKE BOXES FOR COACH LIGHTS REQUIRE BUSHINGS OR CONNECTORS FOR CABLES. INSPECTION STOPPED. HAVE ELECTRICAL CONTRACTOR CHECK FOR CODE COMPLIANCE AND APPROVED PLAN REQUIREMENTS BEFORE NEXT INSPECTION.CABLES NOT USED AS MEANS OF SUPPORT.300.11(2)C. WALL SPACE...210.52A1. NAIL PLATES ON ELECTRIC NEC.300.4 STRAPPING OF ROMEX NEC.334.30. REQUIRED OUTLETS AND SPACING OF OUTLETS. NEC 2008 210.52 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/23/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 4/23/2014 3:36:07 PM LOOSE SHEATHING FRONT LEFT OF HOUSE.(CIRCLED ON PLANS). MISSING TRUSS ENGINEERING ON TRUSS 12. LEFT PAGE OPENON TRUSS AND CIRCLED MISSING PIECE. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/21/2014 | CANCELLED BY APPLICANT | AIRS WEB |
| TIE BEAM / LINTEL | 04/01/2014 | APPROVED | DROCKWELL |
| FOUND SURVEY APPROVED (OFFICE) | 03/19/2014 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 03/19/2014 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/14/2014 | APPROVED | DROCKWELL |
| GRAVITY SEWER TEST | 03/14/2014 | APPROVED | DROCKWELL |
| STEM WALL FOUNDATION | 03/11/2014 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 06/11/2014 | 06/11/2014 |
| Note: Released By: JHINDMAN FINAL SURVEY | |||
| SW1 | COMPLETE | 03/19/2014 | 03/19/2014 |
| Note: Released By: JHINDMAN | |||
| URB | COMPLETE | 01/29/2014 | 01/30/2014 |
| BLD | COMPLETE | 01/28/2014 | 01/28/2014 |
| ELEC | COMPLETE | 01/28/2014 | 01/28/2014 |
| ENGIN1 | COMPLETE | 01/28/2014 | 01/29/2014 |
| MECH | COMPLETE | 01/28/2014 | 01/28/2014 |
| PLUM | COMPLETE | 01/28/2014 | 01/28/2014 |
| SW1 | COMPLETE | 01/28/2014 | 01/28/2014 |
| UD1 | COMPLETE | 01/28/2014 | 01/30/2014 |
| URB | HOLD | 01/28/2014 | 01/29/2014 |
| Note: Need to submit a landscape plan | |||
| ZON | COMPLETE | 01/28/2014 | 01/29/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| REINSPECTION FEE | ¤40.00 | 06/20/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤606.00 | 02/13/2014 |
| SITE PLAN 20 | ¤20.00 | 02/13/2014 |
| SURCHARGE FS 533.721 | ¤22.09 | 02/13/2014 |
| SURCHARGE - FS 468.631 | ¤22.09 | 02/13/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/13/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 02/13/2014 |
| ADMIN FEE | ¤20.00 | 02/13/2014 |
| ELECTRIC FEE | ¤241.80 | 02/13/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 02/13/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 02/13/2014 |
| IMPACT FEE PARKS | ¤1,343.98 | 02/13/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/13/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 02/13/2014 |
| MECHANICAL FEE | ¤241.80 | 02/13/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤40.32) | 02/13/2014 |
| PLAN CHECK FEE | ¤121.20 | 02/13/2014 |
| PLUMBING FEE | ¤241.80 | 02/13/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,888.73 |