Permit #2014020208
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7015-00030-2400 |
| Block: 00030 |
| Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE |
| Job Phone: (386)566-5274 |
| Location Address: 133 CIMMARON DR |
| Type: PO - POOL |
| Issue Date: 03/12/2014 |
| NOC: RECORDED |
| Applicant name: RALPH T LEE JR |
| Owner: LORD, CHAD & TAMI MARSHALL |
|
Address 133 CIMMARON DR PALM COAST, FL 32137 |
| Lot: 2400 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: POOL W/SCREEN ENCLOSURE & GAS TANK FOR POOL HEATER |
| Type: CN |
Contractor
AQUATIC DESIGN SYSTEMS INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
2090 S. NOVA RD SOUTH DAYTONA, FL 32119 |
UNIT AA 01 BOX 13 SOUTH DAYTONA, FL 32119 |
CPC1457500 (Exp: 08/31/2016) | (386)566-5274 | (386)767-3523 |
Sub Contractors
JOHN WAYNE YANEY II
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1812 TRAVELERS PALM DR. EDGEWATER, FL 32132 |
EC13003852 (Exp: 08/31/2020) | 386-427-5687 | 386-424-9652 |
DAVID R ROWE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
45 SOUTH DIXIE HIGHWAY ST. AUGUSTINE, FL 32084 |
01593 (Exp: 08/08/2022) | 904-824-2605 |
EDWARD MILLER
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO BOX 238179 PORT ORANGE, FL 32129 |
CRC1330597 (Exp: 08/31/2020) | 386-756-8770 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 03/18/2015 | FINAL APPROVED | MBACON |
| POOL FINAL | 10/02/2014 | FINAL APPROVED | CMINI |
| FINAL SURVEY (OFFICE USE ONLY) | 09/11/2014 | APPROVED | JHINDMAN |
| ELECTRIC AND ALARM | 08/07/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROW DAMAGE | 07/23/2014 | APPROVED | RGROSS |
| Note: NO permit paperwork on site. Could not sign. | |||
| GAS FINAL | 07/23/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC AND ALARM | 07/23/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 7/23/2014 2:43:03 PM METAL SCREEN ENCLOSURE NEEDS TO BE BONDED .. NEC. 680.26 (7) | |||
| GAS FINAL | 06/24/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/24/2014 3:26:38 PM RELIEF VALVE NEEDED ON SPA HEATER..4101.14.5....ELECTRIC AND ALARM NEEDED TO BE APPROVED BEFORE WATER WAS INSTALLED AND THIRD PARTY APPROVAL FOR CHECKING BONDING IN LIGHT NICHE IS NEEDED... | |||
| GAS ROUGH | 05/23/2014 | APPROVED | CMINI |
| POOL DECK | 05/06/2014 | APPROVED | CMINI |
| POOL DECK | 05/05/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 5/5/2014 3:24:44 PM NEED TO HAVE DETAIL APPROVED BY BUILDING DEPT FOR FOOTER ON SITE FOR INSPECTION | |||
| STEEL AND GROUND | 03/31/2014 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/11/2014 | 09/11/2014 |
| Note: Released By: JHINDMAN final survey | |||
| BLD | COMPLETE | 05/05/2014 | 05/06/2014 |
| Note: Released By: JHINDMAN | |||
| BLD | COMPLETE | 04/30/2014 | 05/01/2014 |
| BLD | COMPLETE | 03/03/2014 | 03/03/2014 |
| ZON | COMPLETE | 03/03/2014 | 03/03/2014 |
| BLD | HOLD | 02/27/2014 | 02/28/2014 |
| Note: Previous hold comments items 2,3,and 4 shall be addressed - F. Reodica -386-986-4734 2. Provide location of underground gas tank on site plan with set back dimensions from building and property line per NFPA 58 Sec. 6.3.4.2. 3. Provide tracer wire requirement for underground non-metallic piping per 2010 FBC FG 404.15.3. 4. Provide gas delivery pressures at first and second stage regulators per 2010 FBC FG 402.1. | |||
| BLD | HOLD | 02/25/2014 | 02/26/2014 |
| Note: Review comments based on new plans submittal - F. Reodica-386-986-4734. 1. Screen enclosure dimensions on plan and elevation do not match. Coordinate and submit correction per 2010 FBC 107.2.1. 2. Provide location of underground gas tank on site plan with set back dimensions from building and property line per NFPA 58 Sec. 6.3.4.2. 3. Provide tracer wire requirement for underground non-metallic piping per 2010 FBC FG 404.15.3. 4. Provide gas delivery pressures at first and second stage regulators per 2010 FBC FG 402.1. | |||
| ZON | COMPLETE | 02/25/2014 | 02/26/2014 |
| BLD | HOLD | 02/10/2014 | 02/10/2014 |
| Note: Provide gas contractor and gas riser diagram for gas heater installation per 2010 FBC 107.2.1. | |||
| SW1 | COMPLETE | 02/10/2014 | 02/10/2014 |
| ZON | HOLD | 02/10/2014 | 02/12/2014 |
| Note: 1. Per Land Development Code Chapter 4, Section 4.01.08 - 2. All swimming pools, hot tubs and spas shall be enclosed by a permanent full screen enclosure or with a permanent wall or fence of at least 4' in height. Please provide details with proper specifications of what this pool will be enclosed by. 2. Foundation shrubbery plantings are required along the side and/or rear of the structure that faces a fresh or saltwater canal, lake, golf course, or public right-of-way. (LDC, Subsection 11.03.02.C.2.b) Foundation shrubs, 3-gallon container, ground covers, 1-gallon container. Required foundation shrubs must be evergreen and freeze tolerant. Foundation shrubs are to be placed every 3 to 4 feet on center. (LDC, Subsection 11.03.05.C Table 11-3). Revise plans to show required landscaping. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/06/2014 |
| REVISION | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| ADMIN FEE | ¤20.00 | 03/12/2014 |
| PERMIT FEE | ¤160.00 | 03/12/2014 |
| PLAN CHECK FEE | ¤40.00 | 03/12/2014 |
| SITE PLAN 20 | ¤20.00 | 03/12/2014 |
| SURCHARGE FS 533.721 | ¤3.30 | 03/12/2014 |
| SURCHARGE - FS 468.631 | ¤3.30 | 03/12/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/12/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤486.60 |