Status: FINAL
| Parcel Id: 07-11-31-7001-000A0-0087 |
| Block: 000A0 |
| Subdivision: 1238 - PALM HARBOR CENTER REPLAT |
| Job Phone: (386)931-1917 |
| Location Address: 9 HARBOR CENTER DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 03/07/2014 |
| NOC: RECORDED |
| Applicant name: BRAD MICHAEL THOMAS |
| Owner: ROLAND MICHEL & MANUELA F. FERREOL |
|
Address 5525 DATIL PEPPER ROAD ST AUGUSTINE, FL 32086 |
| Lot: 0087 |
| Contracted Stated Job Value: ¤5,500.00 |
| Job Description: UNIT 17 - REPLACE ADDITION 4.5 X 4.5 FIRE RISER CABINET |
| Type: CN |
Contractor
AUBURN HOMES INC.
| Status | Location Address | State License Number | Phone |
| HOLD |
1 HARGROVE GRADE STE 1E PALM COAST, FL 32137 |
CGC1506292 (Exp: 08/31/2020) | (386)931-1917 |
Sub Contractors
YORDANIS GONZALEZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
33 RICKENBACKER DRIVE PALM COAST, FL 32164 |
CCC1328730 (Exp: 08/31/2026) | 386-804-4109 |
Inspection History
| Type | Request Date | Result | Inspector |
| BUILDING FINAL | 04/17/2014 | FINAL APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 04/17/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| BUILDING FINAL | 04/16/2014 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 04/16/2014 | CANCELLED BY APPLICANT | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 04/11/2014 | Disapproved - NO FEE | JHINDMAN |
| Note: Inspection Resulted at 4/11/2014 1:44:09 PM 1. PROVIDE RISER ROOM SIGN ON DOOR. 2. PROVIDE ACCESS TO INSPECT, DOOR LOCKED. | |||
| BUILDING FINAL | 04/11/2014 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: Inspection Resulted at 4/11/2014 1:44:10 PM 1. PROVIDE RISER ROOM SIGN ON DOOR. 2010 FBC 914.2. | |||
| LDSC- LANDSCAPE FINAL | 04/11/2014 | APPROVED | WBUTLER |
| U - UTILITY COMMERCIAL FINAL | 04/11/2014 | FINAL APPROVED | DSPENCER |
| FRAMING | 03/24/2014 | APPROVED | CMINI |
| ROOF SHEATHING / BRACE / TIE DOWN | 03/24/2014 | APPROVED | CMINI |
| MONOLITHIC SLAB | 03/14/2014 | APPROVED | RMARVEL |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/03/2014 | 03/03/2014 |
| ZON | COMPLETE | 03/03/2014 | 03/03/2014 |
| DSD | COMPLETE | 03/03/2014 | 03/03/2014 |
| PLLA | COMPLETE | 02/21/2014 | 02/25/2014 |
| BLD | HOLD | 02/19/2014 | 02/19/2014 |
| Note: 1. Provide detail showing roof attachment of proposed utility shed to existing building per 2010 FBC 107.2.1. 2. Provide Florida product approval of the roofing material to be used per 2010 FBC 107.2.1. Reviewed by Reodica | |||
| DSD | HOLD | 02/19/2014 | 02/21/2014 |
| Note: Revise the site plan to show location of shed meets the side setback of 10ft. Provide a landscape plan to show you will shield t from the building. Revised comment 2/25/14jg per bill butlers inspection Revise site plan to show work as a Fire Riser Cabinet and you are replacing existing instead of proposed. Revise plan to be constant with the site plan. Plans show cabinet as 3 x3 but site plan says 4.5 x 4.5. | |||
| ENGIN1 | COMPLETE | 02/19/2014 | 02/24/2014 |
| FI1 | COMPLETE | 02/19/2014 | 02/19/2014 |
| SW1 | COMPLETE | 02/19/2014 | 02/24/2014 |
| UD1 | COMPLETE | 02/19/2014 | 02/20/2014 |
| ZON | HOLD | 02/19/2014 | 02/20/2014 |
| Note: Revise the site plan to show location of shed meets the side setback of 10ft. Provide a landscape plan to show you will shield t from the building. Revised comment 2/25/14jg per bill butlers inspection Revise site plan to show work as a Fire Riser Cabinet and you are replacing existing instead of proposed. Revise plan to be constant with the site plan. Plans show cabinet as 3 x3 but site plan says 4.5 x 4.5. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 03/07/2014 |
| INSPECTION - COMMERCIAL ADD | ¤50.00 | 03/07/2014 |
| FIRE PLANS REVIEW | ¤25.00 | 03/07/2014 |
| PLAN CHECK FEE | ¤100.00 | 03/07/2014 |
| SITE PLAN 20 | ¤20.00 | 03/07/2014 |
| SURCHARGE FS 533.721 | ¤3.15 | 03/07/2014 |
| SURCHARGE - FS 468.631 | ¤3.15 | 03/07/2014 |
| REINSPECTION FEE | ¤40.00 | |
| Fees | Total Due: ¤40.00 | Total Paid: ¤261.30 |