I want to search for...

Permit #2014020658

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00850-0040
CONDITIONED SPACE: 2745 sqft
GARAGE: 742 sqft
OPENED PORCH (WITH ROOF) : 160 sqft
OPENED PORCH (WITH ROOF) : 131 sqft
Total Square Footage: 3778 sqft
Block: 00850
Subdivision: 2211 - SECTION 59-SEMINOLE PARK
Job Phone: 386-672-6101
Location Address: 17 SEA GARDEN PATH
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/31/2014
NOC: RECORDED
Applicant name: JOHN DAVID MINABERRY
Owner: COLLISON FRED & DONNA H&W

Address

250 ELK BRANCH RD

HEDGESVILLE, WV 25427

Lot: 0040
Contracted Stated Job Value: ¤309,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

KEYSTONE HOMES
Status Location Address State License Number Phone Fax
ACTIVE

1339 W GRANADA BLVD

ORMOND, FL 32174

CRC1329222 (Exp: 08/31/2026) 386-672-6101 386-672-6102

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156
WAYNE A PHILLIPS
Status Location Address State License Number Phone Fax
ACTIVE

357 ANDREWS ST

ORMOND BEACH, FL 32174

CVC56698 (Exp: 08/31/2026) (386)673-9720 (386)673-9840

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/29/2014 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 10/29/2014 Disapproved -FEE REQUIRED DSPENCER
Note: Inspection Resulted at 10/29/2014 9:57:12 AM THE SEWER CLEANOUT AT THE PEP TANK MUST BE A FLAT SLOTTED CAP FLUSH WITH THE GRADE/GROUND. ALSO THE TANK CHAMBER AND CUTOFF BOX CANNOT BE LOWERED SO THE SOD SHOULD BE REMOVED AND FILL ADDED TO RAISE THE GRADE TO MEET THEM BECAUSE THE GROUND AROUND THEM WAS LEFT NOTICEABLE LOW THEN THE SOD RESET TO IMPROVE FUNCTION AND THE APPERANCE FOR THE CUSTOMER.
U -UTILITY RESIDENTIAL FINAL 10/29/2014 FINAL APPROVED DSPENCER
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 10/28/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 10/28/2014 11:36:45 AM LABEL AHU FOR MAX BREAKER/OUTLETS LOOSE IN WALL BACK BEDROOM LEFT OF KITHEN MASTER BEDROOM AND BATH/REAR EXIT BATH DOOR LIGHT NOT WORKING/BREAKER IN PANEL FOR DINING ROOM AND NOOK TO BE ARCH-FAULT/REMOVE FORMS AT CONDENSING UNIT.
ROW FINAL 10/27/2014 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION ON SITE WITH BUILDER / OWNER ALL DAMAGE REPAIRED ON SITE FINALED , CALL GARY LALIMA IF NEEDED 386-585-0287
FINAL APRON (AFTER POUR/DRIVEWAY) 10/24/2014 APPROVED GLALIMA
ROW FINAL 10/24/2014 Disapproved -FEE REQUIRED GLALIMA
Note: PLACE SOD IN MEDIAN : CUT AND PLACE SOD TO CORRECT ELEVATION WITH BAHIA SOD CLEAN OUT ENDS OF CULVERT PIPE
FINAL SURVEY (OFFICE USE ONLY) 10/21/2014 APPROVED JHINDMAN
GRAVITY SEWER TEST 10/09/2014 APPROVED DROCKWELL
U - SEWER TIE IN 10/07/2014 APPROVED DSPENCER
ELECTRIC - EARLY POWER 09/30/2014 APPROVED DROCKWELL
PRE-APRON (PRE-POUR/DRIVEWAY) 09/18/2014 APPROVED RGROSS
INSULATION 07/28/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 07/25/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 7/25/2014 10:28:10 AM MISSING FIRE BLOCKING MULTIPLE LOCATIONS. REPLACE CRUSHED 14/3 NM CBLE AT LEFT REAR AREA FOR TRAVELERS.
LATH/BRICK/ WATER BARRIER 07/25/2014 APPROVED RMARVEL
ALL ROUGH 07/15/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 07/10/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 7/10/2014 10:59:14 AM MANY WINDOWS NOT FASTENED-CHECK ALL/NEED 5FT OF HEAD PRESSURE ON SANITARY LINES/FIREBLOCKING IN MASTER BATH/NEED LETTER OR REVISED PLAN SHOWING ADDED OUTLETS IN MANY ROOMS ALSO ADDED FLOOD LIGHTS NOT ON PLAN/PROVIDE PRODUCT APPROVAL SHEETS ON ALL WINDOWS SHOWING ATTACHMENTS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/09/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/9/2014 10:40:38 AM UPPER ROOF RIDGE STRAP NOT ATTACHED TO LOWER TRUSS-WILL CHECK AT NEXT INSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 7/1/2014 2:07:28 PM TIGHTEN THREADED RODS/UPPER ROOF NOT STRAPPED TO LOWER ROOF/ GIRDER TRUSS 08 NOT MEETING BEARING REQUIREMENTS/FIREBLOCK CHASES
TIE BEAM / LINTEL 05/22/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 05/21/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 5/21/2014 3:37:40 PM DRILL AND EPOXY NEW DOWEL WHERE MARKED GREEN
FOUND SURVEY APPROVED (OFFICE) 05/20/2014 APPROVED JHINDMAN
MONOLITHIC SLAB 05/08/2014 APPROVED DROCKWELL
ELECTRIC TEMP POLE 05/08/2014 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 05/01/2014 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/20/2014 10/21/2014
Note: Released By: JHINDMAN foundation survey
BLD COMPLETE 07/11/2014 07/11/2014
ELEC COMPLETE 07/11/2014 07/11/2014
Note: Released By: JMCGOWEN
BLD COMPLETE 07/08/2014 07/08/2014
SW1 COMPLETE 05/20/2014 05/20/2014
Note: Released By: JHINDMAN foundation survey
UD1 COMPLETE 03/13/2014 03/14/2014
Note: See comments in the general notes Keith King 386-9318009
ZON COMPLETE 03/12/2014 03/13/2014
ELEC COMPLETE 03/12/2014 03/13/2014
PLUM COMPLETE 03/12/2014 03/13/2014
BLD COMPLETE 02/24/2014 02/25/2014
ELEC COMPLETE 02/24/2014 02/25/2014
ENGIN1 COMPLETE 02/24/2014 02/28/2014
MECH COMPLETE 02/24/2014 02/25/2014
PLUM HOLD 02/24/2014 02/25/2014
Note: Washing machine as shown on sanitary riser diagram can not be tied into wet vented bathroom group per 2010 FBC R P3108.1. Reviewed by Reodica - 386-986-4734.
SW1 COMPLETE 02/24/2014 02/25/2014
UD1 HOLD 02/24/2014 02/25/2014
Note: The Elec plans need to show the PEP panel on the right side of the house looking at it from the street. Keith King 386-9318009
URB COMPLETE 02/24/2014 02/25/2014
ZON HOLD 02/24/2014 02/26/2014
Note: Pending final recording of City's Release of Easement

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REINSPECTION FEE ¤40.00 10/30/2014
REVISION ¤40.00 10/30/2014
REVISION ¤40.00 10/30/2014
SITE PLAN 20 ¤20.00 03/31/2014
SURCHARGE FS 533.721 ¤24.86 03/31/2014
SURCHARGE - FS 468.631 ¤24.86 03/31/2014
STORM WATER PERMIT FEES ¤80.00 03/31/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 03/31/2014
NEW RESIDENTIAL INSPECTIONS ¤694.00 03/31/2014
ADMIN FEE ¤20.00 03/31/2014
ELECTRIC FEE ¤268.20 03/31/2014
3% FIRE IMPACT FEE CREDIT (¤6.24) 03/31/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 03/31/2014
IMPACT FEE PARKS ¤1,343.98 03/31/2014
IMPACT FEE SCHOOL ¤3,600.00 03/31/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 03/31/2014
MECHANICAL FEE ¤268.20 03/31/2014
3% PARKS IMPACT FEE CREDIT (¤40.32) 03/31/2014
PLAN CHECK FEE ¤138.80 03/31/2014
PLUMBING FEE ¤268.20 03/31/2014
Fees Total Due: ¤0.00 Total Paid: ¤10,199.07