Permit #2014030064
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-00450-0040 |
| CONDITIONED SPACE: 2508 sqft |
| GARAGE: 543 sqft |
| OPENED PORCH (WITH ROOF) : 193 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 3304 sqft |
| Block: 00450 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: (386)254-5081 |
| Location Address: 5 ESSEX LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/08/2014 |
| NOC: RECORDED |
| Applicant name: WAYNE LAWRENCE ADAMS |
| Owner: ADAMS HOMES OF NORTHEAST FL INC |
|
Address 3000 GULF BREEZE PKWY GULF BREEZE, FL 32563 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤165,200.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
ADAMS HOMES OF NW FLORIDA INC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1101 Gulf Breeze Parkway Suite 229 Gulf Breeze, FL 32561 |
CBC043518 (Exp: 08/31/2014) | (386)254-5081 | (386)252-8284 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2018) | (407)333-2665 | (407)585-1002 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
IAN MICHEAL JOHNSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4244 JACKSON STREET PORT ORANGE, FL 32127 |
CCC1325915 (Exp: 08/31/2026) | 386-760-0764 | 386-760-3080 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
DONALD EDWIN KITNER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
450 SOUTH HIGHWAY 17-92 DEBARY, FL 32713 |
CFC057164 (Exp: 08/31/2010) | (386)668-2600 | (386)668-3892 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 08/12/2014 | FINAL APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 08/11/2014 | Disapproved -FEE REQUIRED | DSPENCER |
| Note: Inspection Resulted at 8/11/2014 9:15:30 AM NO POWER TO PEP PANEL TO TEST THE SEWER SYSTEM OR PROTECT HOME FROM SEWER BACKUP | |||
| BLD - BUILDING FINAL | 08/08/2014 | FINAL APPROVED | DROCKWELL |
| GAS FINAL | 08/08/2014 | FINAL APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| GAS FINAL | 08/07/2014 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 8/7/2014 11:40:06 AM •SHUT OFF VALVE NEEDS TO BE 6’ FROM APPLIANCE WITHIN THE SAME ROOM….FBC2420.5.1 | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 08/05/2014 | APPROVED | GLALIMA |
| ROW FINAL | 08/05/2014 | APPROVED | GLALIMA |
| FINAL SURVEY (OFFICE USE ONLY) | 08/01/2014 | APPROVED | JMCGOWEN |
| ELECTRIC - EARLY POWER | 07/25/2014 | APPROVED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/25/2014 2:56:05 PM CALLED FPL AT 255. | |||
| ELECTRIC - EARLY POWER | 07/23/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 7/23/2014 1:49:21 PM FLOOR RECEPTACLES CONDUCTORS NEED TO BE SAFED OFF. | |||
| GRAVITY SEWER TEST | 07/02/2014 | APPROVED | JCOLASANTI |
| U - SEWER TIE IN | 07/02/2014 | APPROVED | DSPENCER |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/02/2014 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| INSULATION | 06/17/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 06/16/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 6/16/2014 2:16:53 PM BATT INSULATION MISSING BEHIND BOTH SHOWER ENCLOSURES-WALLS SHOULD BE INSULATED BEFORE SETTING THE UNITS | |||
| GAS ROUGH | 06/11/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/11/2014 3:13:23 PM CHECK PRESSURE AGAIN AT INSULATION | |||
| ALL ROUGH | 06/11/2014 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/05/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/5/2014 4:12:07 PM REVISE ELECTRICAL PLANS TO EXISTING WORK. ALL WHITE CONDUCTORS BEING USED AS HOTS NEED TO BE IDENTIFIED AS SUCH. PROVIDE GROUNDING JUMPER FROM TERMINAL STRIP TO TERMINAL STRIP.#6 AWG MINIMUM.EXTREMELY DAMAGED NMCABLE AT FIRE PLACE. REPLACE. INSPECTION STOPPED. NOT READY FOR INSPECTION. NEC 2008. | |||
| GAS ROUGH | 06/05/2014 | Disapproved -FEE REQUIRED | RMARVEL |
| Note: Inspection Resulted at 6/5/2014 4:12:08 PM GAS PIPE NEEDS TO BE BONDED AT TIME OF THIS INSPECTION. | |||
| ALL ROUGH | 06/03/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 6/3/2014 3:59:11 PM ELECTRICAL PLANS NOT IN ANY PAPERWORK AVAILABLE | |||
| WINDOW NAILING | 05/27/2014 | APPROVED | DROCKWELL |
| LATH/BRICK/ WATER BARRIER | 05/20/2014 | APPROVED | DROCKWELL |
| FOUND SURVEY APPROVED (OFFICE) | 05/15/2014 | APPROVED | JHINDMAN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/15/2014 | APPROVED | DROCKWELL |
| WALL SHEATHING | 05/12/2014 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 05/01/2014 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH UNDERGROUND | 04/29/2014 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/31/2014 | 08/01/2014 |
| Note: Released By: JMCGOWEN final survey | |||
| ELEC | COMPLETE | 06/06/2014 | 06/06/2014 |
| ZON | COMPLETE | 05/16/2014 | 05/16/2014 |
| BLD | COMPLETE | 05/16/2014 | 05/16/2014 |
| SW1 | COMPLETE | 05/14/2014 | 05/15/2014 |
| Note: Released By: JHINDMAN found s | |||
| BLD | HOLD | 04/15/2014 | 04/15/2014 |
| Note: Held By: JMCGOWEN Provide complete gas line riser detail FBC 107.2.1 | |||
| UD1 | COMPLETE | 04/02/2014 | 04/02/2014 |
| Note: See comment in general notes Danny Spencer 386-569-9082 | |||
| ELEC | COMPLETE | 04/02/2014 | 04/02/2014 |
| MECH | COMPLETE | 04/02/2014 | 04/02/2014 |
| BLD | COMPLETE | 03/04/2014 | 03/05/2014 |
| ELEC | HOLD | 03/04/2014 | 03/05/2014 |
| Note: Relocate receptacles to meet NEC 210.52 | |||
| ENGIN1 | COMPLETE | 03/04/2014 | 03/12/2014 |
| MECH | HOLD | 03/04/2014 | 03/05/2014 |
| Note: Directional orientation of the building shown on energy and equipment sizing calculations does not match with the orientation shown on site plan. Coordinate and submit corrections per 2010 FBC 107.2.1. | |||
| PLUM | COMPLETE | 03/04/2014 | 03/05/2014 |
| SW1 | COMPLETE | 03/04/2014 | 03/05/2014 |
| UD1 | HOLD | 03/04/2014 | 03/05/2014 |
| Note: The elec plan shows the PEP Panel on the wrong side of the House per the Utility marked up site plan. | |||
| URB | COMPLETE | 03/04/2014 | 03/05/2014 |
| ZON | COMPLETE | 03/04/2014 | 03/05/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/13/2014 |
| REINSPECTION FEE | ¤40.00 | 08/13/2014 |
| REINSPECTION FEE | ¤40.00 | 08/13/2014 |
| REVISION | ¤40.00 | 07/22/2014 |
| REVISION | ¤40.00 | 07/22/2014 |
| CONTRACTOR CHANGE | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| REINSPECTION FEE | ¤40.00 | 07/22/2014 |
| PARKS IMPACT FEE | ¤894.24 | 07/22/2014 |
| PLAN CHECK FEE | ¤124.40 | 04/08/2014 |
| PLUMBING FEE | ¤246.60 | 04/08/2014 |
| ADMIN FEE | ¤20.00 | 04/08/2014 |
| ELECTRIC FEE | ¤246.60 | 04/08/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.24) | 04/08/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤207.99 | 04/08/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/08/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 04/08/2014 |
| MECHANICAL FEE | ¤246.60 | 04/08/2014 |
| SITE PLAN 20 | ¤20.00 | 04/08/2014 |
| SURCHARGE FS 533.721 | ¤22.59 | 04/08/2014 |
| SURCHARGE - FS 468.631 | ¤22.59 | 04/08/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/08/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 04/08/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤622.00 | 04/08/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,673.91 |