I want to search for...

Permit #2014030067

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00290-0280
CONDITIONED SPACE: 1882 sqft
GARAGE: 423 sqft
OPENED PORCH (WITH ROOF) : 116 sqft
OPENED PORCH (WITH ROOF) : 41 sqft
Total Square Footage: 2462 sqft
Block: 00290
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: (386)254-5081
Location Address: 5 WESTROCK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/03/2014
NOC: RECORDED
Applicant name: WAYNE LAWRENCE ADAMS
Owner: ADAMS HOMES OF NORTHWEST FL. INC

Address

3000 GULF BREEZE PARKWAY

GULF BREEZE, FL 32563

Lot: 0280
Contracted Stated Job Value: ¤117,600.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

ADAMS HOMES OF NW FLORIDA INC
Status Location Address State License Number Phone Fax
INACTIVE

1101 Gulf Breeze Parkway Suite 229

Gulf Breeze, FL 32561

CBC043518 (Exp: 08/31/2014) (386)254-5081 (386)252-8284

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/28/2014 FINAL APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ROW FINAL 07/28/2014 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 07/25/2014 Disapproved - NO FEE RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 7/25/2014 2:56:06 PM HOT/COLD REVERSE AT KITCHEN FAUCET.
U -UTILITY RESIDENTIAL FINAL 07/25/2014 FINAL APPROVED KKING
FINAL APRON (AFTER POUR/DRIVEWAY) 07/24/2014 APPROVED RGROSS
ROW FINAL 07/24/2014 Disapproved -FEE REQUIRED RGROSS
Note: Right side final swale sod grade is way too high. 4 tenths too high at the property line. Regrade right side of swale. See swale sheet Grade Elevations.
BLD - BUILDING FINAL 07/24/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 7/24/2014 2:26:44 PM HOT/COLD REVERSE ON KITCHEN FAUCET.
FINAL SURVEY (OFFICE USE ONLY) 07/23/2014 APPROVED JMCGOWEN
GRAVITY SEWER TEST 07/02/2014 APPROVED RMARVEL
U - SEWER TIE IN 07/01/2014 APPROVED DSPENCER
PRE-APRON (PRE-POUR/DRIVEWAY) 06/27/2014 APPROVED RGROSS
Note: READY TO POUR
ELECTRIC - EARLY POWER 06/27/2014 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ELECTRIC - EARLY POWER 06/26/2014 CANCELLED BY APPLICANT DROCKWELL
INSULATION 05/30/2014 APPROVED RMARVEL
ALL ROUGH 05/27/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
WINDOW NAILING 05/20/2014 APPROVED RMARVEL
ALL ROUGH 05/20/2014 Disapproved -FEE REQUIRED RMARVEL
Note: Inspection Resulted at 5/20/2014 2:54:37 PM PROVIDE PRESSURE ON WATER LINE FOR INSPECTION. ALL WHITE CONDUCTORS BEING USED AS HOT CONDUCTORS NEEDS TO BE PERMANENTLY IDENTIFIED AS SUCH. SMOKE CANNOT BE WITHIN 3FT OF BATHROOM.
LATH/BRICK/ WATER BARRIER 05/19/2014 APPROVED RMARVEL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/19/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION Inspection Resulted at 5/19/2014 3:39:52 PM LOOKED AT WINDOWS.
FOUND SURVEY APPROVED (OFFICE) 05/15/2014 APPROVED JHINDMAN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/12/2014 Disapproved -FEE REQUIRED JHINDMAN
Note: THIS IS A REINSPECTION Inspection Resulted at 5/12/2014 2:45:17 PM TRUSS T16 IS NOT ANCHORED PER PLANS 2010 FBC 107.4
WALL SHEATHING 05/05/2014 APPROVED DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/05/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 5/5/2014 3:10:35 PM NAIL T-01 STRAP/6X6 POST FRONT PORCH NOT STRAPPED/NAIL BEAM TO HANGAR-FRONT PORCH/BOLT MISSING AT T07 GIRDER/NOT READY FOR INSPECTION.INCOMPLETE INSPECTION
MONOLITHIC SLAB 04/25/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
ELECTRIC TEMP POLE 04/25/2014 APPROVED RMARVEL
Note: Inspection Resulted at 4/25/2014 12:46:28 PM CALLED FPL AT 8:48
MONOLITHIC SLAB 04/24/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 4/24/2014 3:03:40 PM BRICK LEDGE FOOTER DOES NOT HAVE CLEAR DEPTH OF 12" FROM TOP TO BOTTOM PER DETAIL FM01
PLUMBING 1ST ROUGH UNDERGROUND 04/23/2014 APPROVED RMARVEL
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 04/22/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 4/22/2014 12:52:46 PM NOT READY FOR INSPECTION.

Review History

Department Status Date In Date Out
SW1 COMPLETE 07/22/2014 07/23/2014
Note: Released By: JMCGOWEN final survey
SW1 COMPLETE 05/14/2014 05/15/2014
Note: Released By: JHINDMAN found s
ELEC COMPLETE 03/27/2014 03/27/2014
BLD COMPLETE 03/04/2014 03/05/2014
ELEC HOLD 03/04/2014 03/05/2014
Note: Relocate receptacles to meet NEC 210.52
ENGIN1 COMPLETE 03/04/2014 03/17/2014
MECH COMPLETE 03/04/2014 03/05/2014
PLUM COMPLETE 03/04/2014 03/05/2014
SW1 COMPLETE 03/04/2014 03/05/2014
UD1 COMPLETE 03/04/2014 03/05/2014
URB COMPLETE 03/04/2014 03/05/2014
ZON COMPLETE 03/04/2014 03/05/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/29/2014
REINSPECTION FEE ¤40.00 07/29/2014
REINSPECTION FEE ¤40.00 07/22/2014
REINSPECTION FEE ¤40.00 07/22/2014
REINSPECTION FEE ¤40.00 07/22/2014
REINSPECTION FEE ¤40.00 07/22/2014
REINSPECTION FEE ¤40.00 07/22/2014
PARKS IMPACT FEE ¤894.24 07/22/2014
PLAN CHECK FEE ¤92.80 04/03/2014
PLUMBING FEE ¤199.20 04/03/2014
ADMIN FEE ¤20.00 04/03/2014
ELECTRIC FEE ¤199.20 04/03/2014
3% FIRE IMPACT FEE CREDIT (¤6.24) 04/03/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤207.99 04/03/2014
IMPACT FEE SCHOOL ¤3,600.00 04/03/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 04/03/2014
MECHANICAL FEE ¤199.20 04/03/2014
NEW RESIDENTIAL INSPECTIONS ¤464.00 04/03/2014
SITE PLAN 20 ¤20.00 04/03/2014
SURCHARGE FS 533.721 ¤17.62 04/03/2014
SURCHARGE - FS 468.631 ¤17.62 04/03/2014
STORM WATER PERMIT FEES ¤80.00 04/03/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 04/03/2014
Fees Total Due: ¤0.00 Total Paid: ¤9,212.17