I want to search for...
Permit #2014040975
Permit Details
Status: COED
| Parcel Id: 48-11-31-1700-00000-0200 |
| CONDITIONED SPACE: 3298 sqft |
| GARAGE: 1013 sqft |
| OPENED PORCH (WITH ROOF) : 613 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| Total Square Footage: 5012 sqft |
| Block: 00000 |
| Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I |
| Job Phone: 386-947-4481 |
| Location Address: 16 NATIVE OAK CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/29/2014 |
| NOC: RECORDED |
| Applicant name: ERIC CHRISTOPHER OLSEN |
| Owner: DAILY, JOSEPH W & LINDA L |
|
Address FAMILY TRUST PALM COAST, FL 32137 |
|
Address 6 RIVER POINT DR PALM COAST, FL 32137 |
| Lot: 0200 |
| Contracted Stated Job Value: ¤500,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
OLSEN CUSTOM HOMES AND CONSULTING INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
CGC1508852 (Exp: 08/31/2026) | 386-947-4481 | (386)947-4484 |
Sub Contractors
BENJAMIN EDWARD SMITH
| Status | Location Address | State License Number | Phone |
| CANCEL |
131 MAGNOLIA AVE DAYTONA BEACH, FL 32114 |
EC13004288 (Exp: 08/31/2016) | 386-265-2687 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JOHN BRADLEY WINFREY JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1685 S. CLARA AVE Deland, FL 32720 |
CFC054901 (Exp: 08/31/2026) | 386-734-0154 | 386-734-2751 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 11/20/2014 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 11/19/2014 | FINAL APPROVED | CMINI |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/19/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION I REMOVED $ 40.00 REINSPECTION FEEEEEEE | |||
| ROW FINAL | 11/19/2014 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 11/18/2014 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NO PINE STRAW IN RIGHT OF WAY AND NEED FINAL SURVY FAILED | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/18/2014 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED FINAL SURVEY FAILED | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/13/2014 | APPROVED | JHINDMAN |
| GRAVITY SEWER TEST | 11/10/2014 | APPROVED | CMINI |
| U - SEWER TIE IN | 11/10/2014 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/20/2014 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION 2 PART POUR HAD A SITE MEET BUILDER ON FRIDAY OCT 17, 2014 HAD ALL ROADBASEIN PLACE AND WAS READY FOR PAVERS . PASSED ANY ISSUE CALL GARY LA LIMA | |||
| ELECTRIC - EARLY POWER | 10/15/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 10/15/2014 10:49:45 AM CALLED FPL TO RELEASE POWER AT 10:30AM,SPOKE WITH DELL | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/10/2014 | PARTIALLY APPROVED | GLALIMA |
| U - SEWER TIE IN | 09/10/2014 | Disapproved -FEE REQUIRED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/10/2014 10:29:08 AM THE 6 X4 REDUCER IS INSTALLED UPSIDE DOWN THE FLAT SIDE MUST BE ON THE BOTTOM BY PALM COAST PUBLIC WORKS DEPARTMENT /UTILITY STANDARDS POLICY | |||
| LATH/BRICK/ WATER BARRIER | 09/10/2014 | APPROVED | CMINI |
| INSULATION | 09/08/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 09/05/2014 | CANCELLED BY APPLICANT | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/03/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 09/03/2014 | Disapproved -FEE REQUIRED | DSPENCER |
| Note: Inspection Resulted at 9/3/2014 1:22:52 PM WORK NOT DONE CHECKED TWICE DURING THE DAY RECIEVED NO CALLS TO SCHEDULE THE INSPECTION TIME OR CANCEL THE INSPECTION | |||
| ALL ROUGH | 09/03/2014 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/3/2014 12:13:46 PM TEST ON DWV AND WATER PIPPING FPC .312 FBC 2503.5.1 | |||
| ALL ROUGH | 09/02/2014 | Disapproved - NO FEE | CMINI |
| Note: Inspection Resulted at 9/2/2014 12:33:58 PM TEST ON DWV AND WATER PIPPING FPC .312 FBC 2503.5.1...CHECK NAIL PLATES ON ELECTRIC.NEC.300.4..GROUNG METAL BOXES.NEC.314.4 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/02/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/2/2014 12:33:58 PM FRONT ENTRY MISSING PROPER CONTINUOUS LOAD PATH | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/22/2014 | Disapproved - NO FEE | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/22/2014 1:13:57 PM PARTIAL WAITING ON REVISION FOR FRONT ENTRY,WANTED TO DRY IN AND TYVEK WALL SHEATHING | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/15/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/15/2014 2:41:45 PM LOOSE SHEATHING AT MASTER BATH...BLOCKING NEEDED AT REAR AT LOOK OUTS...FRONT ENTRY MISSING CONTINUOUS LOAD PATH AND IN NEED OF REVISIONS SHOWING CHANGES..WALL SHEATHING MISSING BLOCKING AT 24" O.C. ..NEED TO REMOVE SHEATHING FOR INTERIOR OF TOWER TO SEE CONNECTIONS... | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/14/2014 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 8/14/2014 1:35:32 PM INSPECTORS STAMPED SET OF PLANS NOT ON SITE/CANNOT SEE ANY ATTACHMENTS AT ENTRY FRAMING/PROVIDE EXTENTION LADDER FOR VIEWING TRUSS/WALL ATTACHMENTS AT ENTRY | |||
| ELECTRIC-TUG | 08/05/2014 | APPROVED | DROCKWELL |
| TIE BEAM / LINTEL | 07/02/2014 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 07/01/2014 | CANCELLED BY APPLICANT | CMINI |
| ELEV CERT-FOUNDATION APPROVAL | 06/24/2014 | APPROVED | DBEVAN |
| Note: Per Denise Bevan Elevation Certificate for BUC is good. | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/24/2014 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 06/09/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 06/06/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/6/2014 3:17:41 PM RELIEVING ARCH NEEDED IN FOOTING WHERE PIPES GO THROUGH FOOTING,NUMEROUS AREAS,CHECK ALL... P2603.5......FRONT COULUMN PADS,PLANS CALLING FOR 16" DEPTH,NEED TO ACHEIVE BY FORMING TOTAL FOOTER TO CORRECT DEPTH OR DIG FOOTER DEEPER | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/04/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/02/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 6/2/2014 3:20:07 PM 5`` HEAD PRESSURE ON DWV MISSING .FBC 2503.5.1....ALSO RISER SHOWING 3" GOING INTO 4" BEFORE EXITING BUILDING |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 11/12/2014 | 11/13/2014 |
| BLD | COMPLETE | 08/27/2014 | 08/28/2014 |
| BLD | HOLD | 08/22/2014 | 08/25/2014 |
| Note: 1. Provide anchor details for the 6x6 posts top and bottom. 2010 FBC 107.2.1. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 08/21/2014 | 08/21/2014 |
| PLFM | COMPLETE | 06/23/2014 | 06/24/2014 |
| Note: No comments. | |||
| SW1 | COMPLETE | 06/23/2014 | 06/24/2014 |
| Note: Released By: FREODICA foundation suvey | |||
| PLUM | COMPLETE | 05/12/2014 | 05/13/2014 |
| PLUM | HOLD | 05/08/2014 | 05/09/2014 |
| Note: 1. Submitted sanitary riser diagram does not show bathroom No.2 but floor plan does show it. Coordinate and submit correction for clarity per 2010 FBC 107.2.1. | |||
| PLFM | COMPLETE | 05/01/2014 | 05/07/2014 |
| BLD | COMPLETE | 04/30/2014 | 05/01/2014 |
| ELEC | COMPLETE | 04/30/2014 | 05/01/2014 |
| ENGIN1 | COMPLETE | 04/30/2014 | 05/01/2014 |
| Note: No swale plan required. | |||
| MECH | COMPLETE | 04/30/2014 | 05/01/2014 |
| PLUM | HOLD | 04/30/2014 | 05/01/2014 |
| Note: Provide gas contractor, gas riser detail and tank size/location for unvented fire place., provide plumbing riser detail FBC 107.2.1 | |||
| SW1 | COMPLETE | 04/30/2014 | 05/01/2014 |
| UD1 | COMPLETE | 04/30/2014 | 05/01/2014 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 04/30/2014 | 05/01/2014 |
| ZON | COMPLETE | 04/30/2014 | 05/01/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REINSPECTION FEE | ¤40.00 | 11/19/2014 |
| REVISION | ¤40.00 | 11/19/2014 |
| REVISION | ¤40.00 | 11/19/2014 |
| SITE PLAN 20 | ¤20.00 | 05/29/2014 |
| SURCHARGE FS 533.721 | ¤34.50 | 05/29/2014 |
| SURCHARGE - FS 468.631 | ¤34.50 | 05/29/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/29/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 05/29/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤1,000.00 | 05/29/2014 |
| ADMIN FEE | ¤20.00 | 05/29/2014 |
| ELECTRIC FEE | ¤360.00 | 05/29/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.33) | 05/29/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤211.11 | 05/29/2014 |
| IMPACT FEE PARKS | ¤894.24 | 05/29/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/29/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 05/29/2014 |
| MECHANICAL FEE | ¤360.00 | 05/29/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤26.83) | 05/29/2014 |
| PLAN CHECK FEE | ¤200.00 | 05/29/2014 |
| PLUMBING FEE | ¤360.00 | 05/29/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤10,467.73 |