I want to search for...

Permit #2014050060

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00340-0020
CONDITIONED SPACE: 1435 sqft
GARAGE: 413 sqft
OPENED PORCH (WITH ROOF) : 300 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
Total Square Footage: 2348 sqft
Block: 00340
Subdivision: 2211 - SECTION 59-SEMINOLE PARK
Job Phone: (904)296-1490
Location Address: 17 SEA FLOWER PATH
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/28/2014
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC

Address

9700 PHILIPS HIGHWAY

JACKSONVILLE, FL 32256

Address

SUITE 102

JACKSONVILLE, FL 32256

Lot: 0020
Contracted Stated Job Value: ¤82,669.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
RONALD KEVIN HAUPT
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 140006

OVIEDO , FL 32765

CAC058534 (Exp: 08/31/2016) 407-880-1539 407-880-2172
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 10/22/2014 Disapproved -FEE REQUIRED DSPENCER
Note: Inspection Resulted at 10/22/2014 1:06:57 PM THE POWER TO THE PEP PANEL IS OFF I CANNOT TEST THE PUMP OPERATIONAND THE CLEANOUT NEAR THE PEP TANK IS TO HIGH AND HAS THE WRONG TYPE CLEANOUT CAP.THE POWER MUST BE AVAILABE AND THE CLEANOUT MUST BE THE FLAT SLOTTED TYPE FLUSH WITH THE GROUND TO PREVENT BEING HIT BY MOWING. THE FINAL GRADE AROUND THE PEP TANK CHAMBER AND SHUTOFF VALVE BOX SHOULD BE ADJUSTED TO MEET THEM AND SOD RESET BECAUSE THEY CANNOT BE ADJUSTED.
U -UTILITY RESIDENTIAL FINAL 10/22/2014 FINAL APPROVED DSPENCER
Note: THIS IS A REINSPECTION
ROW FINAL 10/21/2014 APPROVED GLALIMA
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 10/21/2014 FINAL APPROVED DROCKWELL
ROW FINAL 10/20/2014 Disapproved -FEE REQUIRED GLALIMA
Note: 3rd PARTY LIABILITY ON ELEVATIONS OF INVERT AND OUTLET OF CULVERT PIPE NEED TO BE ON SURVEY '' NUMBERS ON THE FINAL SURVEY ARE THE ELEVATIONS OF THE SOD '' NOT CULVERT
FINAL SURVEY (OFFICE USE ONLY) 10/20/2014 APPROVED JHINDMAN
FINAL APRON (AFTER POUR/DRIVEWAY) 10/16/2014 APPROVED RGROSS
U - SEWER TIE IN 09/24/2014 APPROVED DSPENCER
PRE-APRON (PRE-POUR/DRIVEWAY) 09/18/2014 APPROVED RGROSS
ELECTRIC - EARLY POWER 09/11/2014 APPROVED DROCKWELL
LATH/BRICK/ WATER BARRIER 08/28/2014 APPROVED CMINI
INSULATION 08/20/2014 APPROVED DROCKWELL
ALL ROUGH 08/15/2014 APPROVED - AS NOTED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 8/15/2014 11:36:45 AM MISSING 2 OUTLETS ON PLAN/REVISE ELEC TO SHOW RE-LOCATED SERVICE PANEL-WILL CHECK AT INSULATION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/12/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 08/12/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 8/12/2014 11:30:57 AM APPROVED STAMPED PLANS NOT ON SITE/NAIL PLATE AT BOTH SIDES AT SERVICE PANEL TOP PLATE/SUPPORT GUEST BATH EXHAUST AT MID-POINT USE TRUSS WEB/NM CABLE HANGING BELOW TRUSSES IN GARAGE/SEAL DRYER DUCT AT BOTTOM ROOF DECK ALSO SUPPORT AT MID-POINT.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/08/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 8/8/2014 12:29:06 PM RE-NAIL FLAT TOP TRUSSES AT SHEATHING JOINT THE ENTIRE LENGTH-SHEETS LOOSE-SEE ORANGE SPRAY/ 2X8 RAFTER SUPPORTING ROOF SHEATHING IS STRUCTURAL-NOT A NAILER ADJUST RAFTER TO SUPPORT ROOF-IN FRONT ENTRY AREA/NOT READY FOR INSPECTION-INCOMPLETE INSPECTION/REMOVE MANY SHINERS
TIE BEAM / LINTEL 07/11/2014 APPROVED DROCKWELL
GRAVITY SEWER TEST 07/02/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 07/02/2014 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 07/02/2014 APPROVED JMCGOWEN
GRAVITY SEWER TEST 06/30/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 6/30/2014 2:32:06 PM PIPE JOINT COVERED UP CAN NOT WIEW CONNECTION- REMOVE CAP ALSO MAKE SURE WATER FLUSH WITH TOP PIPE
PLUMBING 1ST ROUGH UNDERGROUND 06/30/2014 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 06/27/2014 CANCELLED BY APPLICANT DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 06/27/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 6/27/2014 2:31:02 PM WORK HAS YET TO BEGIN-DID NOT HEAR FROM TONY TO CANCEL INSPECTION
FOOTER 06/17/2014 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 10/17/2014 10/20/2014
Note: Released By: JHINDMAN final survey
ELEC COMPLETE 08/18/2014 08/18/2014
SW1 HOLD 07/02/2014 07/02/2014
Note: Held By: JMCGOWEN provide finish floor elevation
SW1 COMPLETE 07/02/2014 07/02/2014
Note: Released By: JMCGOWEN
ENGIN1 COMPLETE 05/12/2014 05/19/2014
BLD COMPLETE 05/09/2014 05/09/2014
ENGIN1 HOLD 05/09/2014 05/09/2014
Note: Surveyor's unable to locate benchmark as depicted on plans. Scott Bombardier 986-3756
UD1 COMPLETE 05/09/2014 05/09/2014
Note: See comments in the general notes Keith King 386-9318009
ELEC COMPLETE 05/09/2014 05/09/2014
Note: Released By: JHINDMAN
BLD HOLD 05/02/2014 05/05/2014
Note: 1. Sheet TR1 does not state which connectors to use from the anchor tables. 2010 FBC 107.2.1.J. Hindman 986-3784.
ELEC HOLD 05/02/2014 05/02/2014
Note: Relocate receptacles to meet NEC 210.52 J McGowen
ENGIN1 HOLD 05/02/2014 05/08/2014
Note: Surveyor's unable to locate benchmark as depicted on plans.
MECH COMPLETE 05/02/2014 05/02/2014
PLUM COMPLETE 05/02/2014 05/02/2014
SW1 COMPLETE 05/02/2014 05/02/2014
UD1 COMPLETE 05/02/2014 05/02/2014
Note: See comments in the general notes Keith King 386-9318009
URB COMPLETE 05/02/2014 05/05/2014
ZON COMPLETE 05/02/2014 05/05/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/24/2014
REINSPECTION FEE ¤40.00 10/24/2014
REINSPECTION FEE ¤40.00 10/24/2014
REINSPECTION FEE ¤40.00 10/24/2014
REINSPECTION FEE ¤40.00 10/24/2014
REVISION ¤40.00 10/24/2014
SITE PLAN 20 ¤20.00 05/28/2014
SURCHARGE FS 533.721 ¤15.41 05/28/2014
SURCHARGE - FS 468.631 ¤15.41 05/28/2014
STORM WATER PERMIT FEES ¤80.00 05/28/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 05/28/2014
NEW RESIDENTIAL INSPECTIONS ¤394.00 05/28/2014
ADMIN FEE ¤20.00 05/28/2014
ELECTRIC FEE ¤178.20 05/28/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 05/28/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 05/28/2014
IMPACT FEE PARKS ¤894.24 05/28/2014
IMPACT FEE SCHOOL ¤3,600.00 05/28/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 05/28/2014
MECHANICAL FEE ¤178.20 05/28/2014
3% PARKS IMPACT FEE CREDIT (¤26.83) 05/28/2014
PLAN CHECK FEE ¤78.80 05/28/2014
PLUMBING FEE ¤178.20 05/28/2014
Fees Total Due: ¤0.00 Total Paid: ¤8,996.95