I want to search for...

Permit #2014070471

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-1140
CONDITIONED SPACE: 3920 sqft
GARAGE: 1110 sqft
OPENED PORCH (WITH ROOF) : 828 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
Total Square Footage: 5894 sqft
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-236-4133
Location Address: 7 BLUE OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/20/2014
NOC: RECORDED
Applicant name: KEVIN MICHAEL MAYS
Owner: LYNE, LANHAM & SHARLA

Address

3707 MAPLEWOOD AVENUE SUITE 200

WICHITA FALLS, TX 76308

Lot: 114
Contracted Stated Job Value: ¤515,363.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

CGC1517573 (Exp: 08/31/2018) 386-236-4133 386-763-7833

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHRIS C KOONTZ
Status Location Address State License Number Phone Fax
INACTIVE

651 CARSWELL AVE

Holly Hill, FL 32117

CAC035563 (Exp: 08/31/2024) (386) 252-1878 (386)252-9703
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856

Inspection History

Type Request Date Result Inspector
PRE-APRON (PRE-POUR/DRIVEWAY) 03/16/2015 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION PASSED ON FEB 11 2015
FINAL APRON (AFTER POUR/DRIVEWAY) 03/13/2015 APPROVED RGROSS
ROW FINAL 03/13/2015 APPROVED RGROSS
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 03/13/2015 FINAL APPROVED DSPENCER
ROW FINAL 03/12/2015 CANCELLED BY APPLICANT GLALIMA
FINAL SURVEY (OFFICE USE ONLY) 03/12/2015 APPROVED FREODICA
Note: THIS IS A REINSPECTION APPROVED FOR RELEASE PER BUILDING OFFICIAL.
BLD - BUILDING FINAL 03/10/2015 FINAL APPROVED DROCKWELL
FINAL SURVEY (OFFICE USE ONLY) 03/05/2015 Disapproved - NO FEE FREODICA
Note: 1. Provide finished floor elevation of pool deck. 2. Provide grading elevations at the back of the pool. 3. Provide surface drainage flow pattern as the survey shows no continous flow to match with approved propose drainge. 4. Provide grading elevations at at 20-foot intervaval along the property line at the right side of the house. It appears that there is a difference of elevations of 2 to 3 ft between adjacent properties. Provide information on how the drainage flow would be accomplised.
FINAL APRON (AFTER POUR/DRIVEWAY) 02/26/2015 APPROVED RGROSS
ELECTRIC - EARLY POWER 02/19/2015 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 2/19/2015 11:57:58 AM CALLED FPL TO RELEASE POWER AT 1130 SPOKE WITHDELL
PRE-APRON (PRE-POUR/DRIVEWAY) 02/11/2015 APPROVED GLALIMA
PRE-APRON (PRE-POUR/DRIVEWAY) 02/10/2015 Disapproved -FEE REQUIRED GLALIMA
Note: NO FORMED RIGHT . AND CHECK TO SEE IF IN LINE SURVEY '' REINSPECTIONS NEEDED ' FEE
U - SEWER TIE IN 02/05/2015 APPROVED DSPENCER
GRAVITY SEWER TEST 02/05/2015 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 01/13/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION system down ok to squedule per Charlie
LATH/BRICK/ WATER BARRIER 01/12/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 1/12/2015 12:37:30 PM STUCCO BEADING NOT COMPLETED
INSULATION 01/09/2015 APPROVED DROCKWELL
ALL ROUGH 01/06/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 12/31/2014 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 12/31/2014 1:51:26 PM MUTIPLE STRAPPING AND SUPPORTING FOR ELECTRICAL NOT READY,TRACK SLIDER ANCHORING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/26/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/25/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 11/25/2014 11:46:16 AM COULD NOT SEE ANCHORS AND STRAPS AT FRONT ENTRY,NEED TO REMOVE SHEATHING TO SEE ANCHORS,COULD NOT SEE ANCHORS FOR TRUSSES A OVER FRONT ENTRY..CONTINUOUS LOAD PATH ON KNEE WALLS IN GARAGE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/20/2014 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 11/20/2014 11:23:47 AM COULD NOT SEE ANCHORS AND STRAPS AT FRONT ENTRY,NEED TO REMOVE SHEATHING TO SEE ANCHORS,COULD NOT SEE ANCHORS FOR TRUSSES A OVER FRONT ENTRY...BUCKETS MISSING OFF OF TRUSS D2.ROUND WALL SHEATHING OK....NEED TO SHOW ANCHORS AT OVER HANG AT GARAGE AND CONTINUOUS LOAD PATH..
WALL SHEATHING 11/20/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 11/20/2014 11:23:48 AM ROUND WALL OK CHECK REST ON REINSPECT OF ROOF SHEATHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/13/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 11/13/2014 3:07:47 PM RE-STRAP 5 TRUSS AT MID-POINT BEARING WALL LEFT SIDE/MANY HOLD-DOWNS NOT ANCHORED/WALL TO BLOCK 2X8``S NOT ANCHORED TO WALL/NOT READY FOR INSPECTION/INCOMPLETE INSPECTION/
WALL SHEATHING 11/13/2014 APPROVED - AS NOTED DROCKWELL
Note: Inspection Resulted at 11/13/2014 3:07:48 PM REMOVE SHINERS WALL SHEATHING MASTER BEDROOM-CHECK ALL AREAS
TIE BEAM / LINTEL 10/20/2014 APPROVED CMINI
ELEV CERT-FOUNDATION APPROVAL 10/16/2014 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 10/15/2014 APPROVED JHINDMAN
ELECTRIC-TUG 10/15/2014 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 10/15/2014 10:49:45 AM CALLED FPL TO RELEASE POWER AT 10:30AM,SPOKE WITH DELL
MONOLITHIC SLAB 10/03/2014 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 09/25/2014 APPROVED CMINI

Review History

Department Status Date In Date Out
PLFM COMPLETE 03/12/2015 03/16/2015
SW1 COMPLETE 03/12/2015 03/12/2015
Note: Released By: FREODICA
SW1 HOLD 03/03/2015 03/05/2015
Note: Held By: FREODICA final survey 1. Provide finished floor elevation of pool deck. 2. Provide grading elevations at the back of the pool. 3. Provide surface drainage flow pattern as the survey shows no continous flow to match with approved propose drainge. 4. Provide grading elevations at at 20-foot intervaval along the property line at the right side of the house. It appears that there is a difference of elevations of 2 to 3 ft between adjacent properties. Provide information on how the drainage flow would be accomplised.
BLD COMPLETE 12/09/2014 12/11/2014
PLFM COMPLETE 10/15/2014 10/16/2014
SW1 COMPLETE 10/15/2014 10/15/2014
Note: Released By: JHINDMAN foundation survey
PLFM COMPLETE 08/13/2014 08/15/2014
PLFM HOLD 08/05/2014 08/12/2014
Note: 1. Will the below propane tank service the residence or the pool or both? 2. Provide calculation of bouoyancy forces for underground propane tank. 3. If propane tank services the residence than the elevation certificate needs to show that information.
URB COMPLETE 08/05/2014 08/06/2014
PLFM HOLD 07/21/2014 07/23/2014
Note: The proposed residence will be serviced with natural gas according to the plans. If service will be provided by storage tank (above or underground), please address the following. The tank shall be installed 1-foot above base flood elevation [10.02.06, LDC] and anchored to ensure that the tank will not be displaced due to buoyancy forces and result in flood hazards. Provide calculations and detail of how the tank will be anchored to minimize threat of such hazards. Please note that the final elevation of the bottom element of the tank may become the lowest servicing equipment to the residence. If this is the result, the elevation certificate will require modification as applicable.
BLD COMPLETE 07/18/2014 07/21/2014
ELEC COMPLETE 07/18/2014 07/18/2014
ENGIN1 COMPLETE 07/18/2014 07/18/2014
Note: No swale plan required.
MECH COMPLETE 07/18/2014 07/21/2014
PLUM COMPLETE 07/18/2014 07/21/2014
SW1 COMPLETE 07/18/2014 07/18/2014
UD1 COMPLETE 07/18/2014 07/18/2014
Note: See comments in the general notes Keith King 386-9318009
URB HOLD 07/18/2014 07/21/2014
Note: 1: Irrigation plan Must indicate re-use water is the source and must use the guidelines set in the technical manual page 42, paragraph R. 2:Schefflera shrubbery can not be used as the primary foundation planting and must be replaced front and left rear.
ZON COMPLETE 07/18/2014 07/21/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/03/2015
REINSPECTION FEE ¤40.00 03/03/2015
REINSPECTION FEE ¤40.00 03/03/2015
REINSPECTION FEE ¤40.00 03/03/2015
REINSPECTION FEE ¤40.00 03/03/2015
REINSPECTION FEE ¤40.00 03/03/2015
NEW RESIDENTIAL INSPECTIONS ¤1,032.00 08/20/2014
SITE PLAN 20 ¤20.00 08/20/2014
SURCHARGE FS 533.721 ¤35.51 08/20/2014
SURCHARGE - FS 468.631 ¤35.51 08/20/2014
STORM WATER PERMIT FEES ¤80.00 08/20/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 08/20/2014
ADMIN FEE ¤20.00 08/20/2014
ELECTRIC FEE ¤369.60 08/20/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 08/20/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 08/20/2014
IMPACT FEE PARKS ¤894.24 08/20/2014
IMPACT FEE SCHOOL ¤3,600.00 08/20/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 08/20/2014
MECHANICAL FEE ¤369.60 08/20/2014
3% PARKS IMPACT FEE CREDIT (¤26.83) 08/20/2014
PLAN CHECK FEE ¤206.40 08/20/2014
PLUMBING FEE ¤369.60 08/20/2014
Fees Total Due: ¤0.00 Total Paid: ¤10,376.95