I want to search for...
Permit #2014070540
Permit Details
Status: COED
| CONDITIONED SPACE: 26460 sqft |
| OPENED PORCH (WITH ROOF) : 7379 sqft |
| Total Square Footage: 33839 sqft |
| Subdivision: 2148 - TOWN CENTER PHASE 8 |
| Job Phone: 407-741-8500 |
| Location Address: 445 LANDING BLVD BLDG 7 |
| Type: BM - BUILDING MULTI - APARTMENT |
| Issue Date: 11/19/2014 |
| NOC: RECORDED |
| Applicant name: SCOTT W CULP |
| Owner: FLORIDA LANDMARK COMMUNITIES LLC |
|
Address 145 CITY PLACE PALM COAST, FL 32164 |
|
Address SUITE 300 PALM COAST, FL 32164 |
| Contracted Stated Job Value: ¤1,922,005.00 |
| Job Description: BUILDING 7 4-STORY APARTMENTS/OCCUPANCY R-2/24 UNITS |
| Type: CN |
Contractor
CPG CONSTRUCTION LLP
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
200 E CANTON AVE # 102 WINTER PARK, FL 32789 |
CGC1512998 (Exp: 08/31/2016) | 407-741-8500 | 407-643-2551 |
Sub Contractors
RANCE F BORDERICK
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
430 WEST DRIVE ALTAMONTE SPRINGS, FL 32714 |
EC0000981 (Exp: 08/31/2026) | (407)788-3500 | 407-788-2007 |
DAVID A CROSON
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
31550 COUNTY ROAD 437 SORRENTO, FL 32776 |
CFC1426109 (Exp: 08/31/2022) | 352-729-7100 | 352-735-0623 |
JOSEPH RICHARD CASSIDY JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
17304 PHIL C PETERS RD WINTER GARDEN, FL 34787 |
CCC1327385 (Exp: 08/31/2020) | 407-654-4426 | (407)654-4307 |
JOHN MAXEN BARTKOVICH
| Status | Location Address | State License Number | Phone |
| ACTIVE |
818 SHADOWMOSS DR WINTERGARDEN, FL 32787 |
CAC1815793 (Exp: 08/31/2026) | 407-886-3729 |
Inspection History
| Type | Request Date | Result | Inspector |
| FIRE FINAL | 05/22/2015 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| U - UTILITY COMMERCIAL FINAL | 05/22/2015 | FINAL APPROVED | DSPENCER |
| BUILDING FINAL | 05/21/2015 | FINAL APPROVED | CMINI |
| FIRE FINAL | 05/21/2015 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: 1. provide fire extinguishers in the units. 2 seal all penetrations in the rated assemblies. 3. controlled access doors must seal when closed. | |||
| PLUMBING FINAL | 05/21/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| HVAC FINAL | 05/21/2015 | APPROVED | CMINI |
| ELECTRIC FINAL | 05/21/2015 | APPROVED | CMINI |
| ELECTRIC - EARLY POWER | 05/01/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/1/2015 2:40:10 PM CALLED FPL TO RELEASE POWER ON FLOORS 3 AND 4, SPOKE WITH SUSAN | |||
| ELECTRIC - EARLY POWER | 04/29/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 4/29/2015 2:56:46 PM CALLED FPL TO RELEASE POWER ON UNITS 201-206, SPOKE WITH SUSAN | |||
| ELECTRIC - EARLY POWER | 04/28/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 4/28/2015 2:22:42 PM 1ST FLOOR UNITS 101-106, CALLED FPL TO RELEASE POWER, SPOKE WITH SUSAN | |||
| ELECTRIC TEMP POLE | 04/23/2015 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/23/2015 9:49:31 AM SPOKE TO DELL FPL 9:45AM RELEASED POWER | |||
| ELECTRIC TEMP POLE | 04/22/2015 | CANCELLED BY APPLICANT | RMARTIN |
| SHEARWALL | 04/06/2015 | APPROVED | CMINI |
| SHEARWALL | 04/02/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 4/2/2015 2:28:29 PM 3RD FLOOR DRYWALL SCREW OFF | |||
| SHEARWALL | 03/31/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 3/31/2015 12:22:02 PM DRYWALL SCREW SPACING | |||
| SHEARWALL | 03/30/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 3/30/2015 2:37:16 PM 1ST FLOOR SHEARWALLS OK | |||
| FIREWALL NAILING | 03/27/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/27/2015 2:23:52 PM C-CHANEL | |||
| FIREWALL NAILING | 03/25/2015 | CANCELLED BY APPLICANT | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FRAMING | 03/25/2015 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 03/25/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION..need to look at data room | |||
| HVAC ROUGH | 03/25/2015 | APPROVED | CMINI |
| PLUMBING 2ND ROUGH | 03/25/2015 | APPROVED | CMINI |
| FIREWALL NAILING | 03/24/2015 | CANCELLED BY APPLICANT | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 03/24/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 3/24/2015 2:53:54 PM BUILDING 7 3RD AND 4TH FLOORS-BATT INSULATION APPROVED | |||
| INSULATION | 03/23/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/23/2015 2:18:51 PM BLDG 7 3RD FLOOR OK TO ROCK | |||
| FIREWALL NAILING | 03/23/2015 | CANCELLED BY APPLICANT | DROCKWELL |
| FRAMING | 03/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 2:32:54 PM 4TH FLOOR UNITS | |||
| HVAC ROUGH | 03/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 2:32:55 PM 4TH FLOOR UNITS | |||
| PLUMBING 2ND ROUGH | 03/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 2:32:55 PM 4TH FLOOR UNITS | |||
| ELECTRIC 2ND ROUGH | 03/20/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 2:32:56 PM 4TH FLOOR UNITS | |||
| INSULATION | 03/20/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 2:32:54 PM 2ND FLOOR UNITS | |||
| INSULATION | 03/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 3/19/2015 2:30:05 PM 1ST FLOOR INSULATION | |||
| ELECTRIC 2ND ROUGH | 03/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/19/2015 2:30:07 PM 3RD FLOOR UNITS | |||
| HVAC ROUGH | 03/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/19/2015 2:30:07 PM 3RD FLOOR UNITS | |||
| PLUMBING 2ND ROUGH | 03/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/19/2015 2:30:08 PM 3RD FLOOR UNITS | |||
| FRAMING | 03/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/19/2015 2:30:06 PM 3RD FLOOR UNITS | |||
| FRAMING | 03/18/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/18/2015 2:09:03 PM 2ND FLOOR UNITS | |||
| PLUMBING 2ND ROUGH | 03/18/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/18/2015 2:09:04 PM 2ND FLOOR UNITS | |||
| HVAC ROUGH | 03/18/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/18/2015 2:09:03 PM 2ND FLOOR UNITS | |||
| ELECTRIC 2ND ROUGH | 03/18/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/18/2015 2:09:04 PM 2ND FLOOR UNITS | |||
| ELECTRIC 2ND ROUGH | 03/17/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 3/17/2015 2:30:53 PM 1ST FLOOR | |||
| HVAC ROUGH | 03/17/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 3/17/2015 2:30:52 PM 1ST FLOOR | |||
| PLUMBING 2ND ROUGH | 03/17/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/17/2015 2:30:53 PM 1ST FLOOR | |||
| FRAMING | 03/17/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/17/2015 2:30:54 PM 1ST FLOOR | |||
| FRAMING | 03/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 3/16/2015 2:56:37 PM ELEVATOR ROOF FRAMING | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 03/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 3/16/2015 2:56:33 PM ENGINEERING AND TIE DOWNS | |||
| PLUMBING 2ND ROUGH | 03/12/2015 | PARTIALLY APPROVED | JHINDMAN |
| Note: sanitary test | |||
| PLUMBING FINAL | 03/12/2015 | CANCELLED BY APPLICANT | JHINDMAN |
| SECOND FLOOR SLAB | 03/06/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 3/6/2015 2:27:17 PM ELAVATOR | |||
| EXTERIOR STRAP/CLIP | 03/06/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/6/2015 1:15:18 PM PORCH STRAPS AND CLIPS 4TH FLOOR BUILDING 7 | |||
| ELECTRIC 1ST ROUGH | 03/05/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/5/2015 3:17:19 PM FIRE CONTROL CONDUIT UNDERGROUND | |||
| TIE DOWN | 03/04/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 3/4/2015 12:31:30 PM THEADED ROD SYSTEM APPROVED | |||
| EXTERIOR STRAP/CLIP | 02/27/2015 | CANCELLED BY APPLICANT | CMINI |
| Note: THIS IS A REINSPECTION | |||
| FIREWALL | 02/27/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/27/2015 12:41:20 PM BREEZWAYS FLOORS 1-4 | |||
| EXTERIOR STRAP/CLIP | 02/25/2015 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/25/2015 2:37:54 PM STAIRWELL FRAMING DOES NOT MATCH APPROVED PLANS.PROVIDE APPROVED REVISIONS/HOLD-DOWN REQUIREMENTS | |||
| WINDOW NAILING | 02/25/2015 | APPROVED | DROCKWELL |
| GRAVITY SEWER | 02/24/2015 | APPROVED | CMINI |
| U - SEWER TIE IN | 02/24/2015 | APPROVED | DSPENCER |
| ROOF SHEATHING / BRACE / TIE DOWN | 02/20/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 2/20/2015 10:51:17 AM BUILDING 7 SHEATHING ONLY-APPROVED | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 02/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/19/2015 12:27:59 PM 4TH FLOOR EXTERIOR NAILING | |||
| EXTERIOR STRAP/CLIP | 02/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/19/2015 12:28:00 PM COLUMN STRAPING 4TH FL | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 02/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/16/2015 2:46:37 PM 2ND AND 3RD FL SHEATHING NAIL PATTERN | |||
| EXTERIOR STRAP/CLIP | 02/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/16/2015 2:46:38 PM 2ND AND 3RD FLOOR COLUMN STRAPS | |||
| RAKE BEAM | 02/16/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 2/16/2015 2:46:37 PM TOP OF SEPERATION WALL | |||
| EXTERIOR STRAP/CLIP | 02/12/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 2/12/2015 10:53:03 AM BALCONY 6X6 POST STRAPPING 1ST FLOOR | |||
| EXTERIOR WALL SHEATHING / SHEARWALL | 02/12/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 2/12/2015 10:53:03 AM 1ST FLOOR WALL SHEATHING OK-SHINERS REMOVED-UNIVERSAL REPORT ON FILE | |||
| ELECTRIC 1ST ROUGH | 02/03/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/3/2015 1:54:27 PM UNDERGROUND FOR PRIMARY FROM TRANSFORMER TO BUILDING | |||
| DOWN CELL | 01/30/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 1/30/2015 10:21:09 AM BUILDING WALL BLOCK | |||
| LINTEL | 01/30/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 1/30/2015 10:21:09 AM 4TH FLOOR AND ELEVATOR SHAFT | |||
| ELECTRIC TEMP POLE | 01/28/2015 | APPROVED | CMINI |
| SHEARWALL | 01/21/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 1/21/2015 3:12:35 PM 3RD FLOOR PARTIAL SHEERWALL.APPROVED. | |||
| SHEARWALL | 01/08/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 1/9/2015 7:23:17 AM THRESHOLD INSPECTION REPORT ON FILE | |||
| MONOLITHIC SLAB | 12/23/2014 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/23/2014 12:16:19 PM OK PER REVISION | |||
| ELECTRIC OTHER | 12/22/2014 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 12/22/2014 3:21:57 PM UNDER SLAB | |||
| MONOLITHIC SLAB | 12/22/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 12/22/2014 3:21:59 PM NEED REVISION FOR FOOTER CHANGE DETAIL | |||
| PLUMBING 1ST ROUGH | 12/19/2014 | APPROVED | JHINDMAN |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH | 12/18/2014 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 12/18/2014 2:14:08 PM PARTIAL ONLY | |||
| FOOTER | 11/21/2014 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 11/21/2014 2:36:49 PM ELEVATOR PIT FOUNDATION WALLS PER PLAN-UNIVERSALS REPORT FILED | |||
| FOOTER | 11/20/2014 | APPROVED - AS NOTED | DROCKWELL |
| Note: PER JEFF Inspection Resulted at 11/20/2014 11:13:12 AM ELEVATOR PIT FOUNDATION BOTH BUILDINGS.FOOTER ONLY.TO PLAN AND CODE. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 05/20/2015 | 05/21/2015 |
| ELEC | COMPLETE | 03/18/2015 | 03/19/2015 |
| BLD | COMPLETE | 03/11/2015 | 03/16/2015 |
| ELEC | HOLD | 03/11/2015 | 03/16/2015 |
| Note: 1. Page E 3.1 was not included with the current correction pages. | |||
| BLD | HOLD | 02/20/2015 | 03/04/2015 |
| Note: 1. On page 5.2 (4) c the dryer vent cannot take up more than 40 percent of the plate. 2010 FBC 2308.9.10. | |||
| ELEC | HOLD | 02/20/2015 | 03/05/2015 |
| Note: 1. Dwelling units must have 20 amp circuits for small appliance circuits, laundry circuits, dining circuits and bathroom circuits per 2008 NEC 210.11 C.and 210.52 B. 2. Page E4.2 is for building 8 This permit is only for building 7. | |||
| MECH | COMPLETE | 02/20/2015 | 03/04/2015 |
| Note: Revision 5 - owner revision dated 2-16-15 | |||
| PLUM | COMPLETE | 02/20/2015 | 03/04/2015 |
| Note: Revision 5 - owner revision dated 2-16-15. Sheet P2.1a - revised condensate drain piping to drain indirectly to storm drain. | |||
| BLD | COMPLETE | 02/11/2015 | 02/13/2015 |
| BLD | COMPLETE | 02/10/2015 | 02/11/2015 |
| MECH | COMPLETE | 02/05/2015 | 02/06/2015 |
| PLUM | COMPLETE | 02/05/2015 | 02/06/2015 |
| BLD | HOLD | 02/05/2015 | 02/05/2015 |
| Note: 1. The detail for U341 was not submitted with the corrections. | |||
| BLD | HOLD | 01/22/2015 | 01/29/2015 |
| Note: 1. Provide U. L. system detail that allows for the alternate intersection for the single/double wall on page S6.1. | |||
| ELEC | COMPLETE | 01/22/2015 | 01/28/2015 |
| MECH | HOLD | 01/22/2015 | 01/27/2015 |
| Note: Revision 4 dated 1-14-15 shows deletion of natural ventilation but on sheet M3.4 ventilation calculation still shows. Clarify and submit correction per 2010 FBC 107.2.1. | |||
| PLUM | HOLD | 01/22/2015 | 01/27/2015 |
| Note: Revision 4 dated 1-14-15, sheet P5.1. Drywell detail still shows but summary of changes show deletion. Coordinate and submit correction per 2010 FBC 107.2.1. | |||
| BLD | COMPLETE | 12/22/2014 | 12/22/2014 |
| ZON | COMPLETE | 11/18/2014 | 11/18/2014 |
| MECH | COMPLETE | 11/06/2014 | 11/07/2014 |
| Note: Rev - changed energy calculations. | |||
| PLUM | COMPLETE | 11/06/2014 | 11/07/2014 |
| Note: Revision 1b dated 11-03-14 - relocated floor drains at breezeway | |||
| ZON | HOLD | 11/06/2014 | 11/13/2014 |
| Note: 1. Please revise sheets A6.2a and A6.2b to include a note that the contractor should refer to the approved color elevations attached to the Site Plan Development Order plans for color manufacturer, color name and color locations on the building. | |||
| BLD | COMPLETE | 11/06/2014 | 11/12/2014 |
| FI1 | COMPLETE | 11/06/2014 | 11/07/2014 |
| ELEC | COMPLETE | 10/23/2014 | 10/24/2014 |
| MECH | HOLD | 10/23/2014 | 10/24/2014 |
| Note: Provide revised energy calculations to affected units due to changes for clarification per 2010 FBC 107.2.1. | |||
| PLUM | HOLD | 10/23/2014 | 10/24/2014 |
| Note: 1. Provide penetration details of hallway floor drains through floors and wall assembly per 2010 FBC 107.2.1. | |||
| ZON | HOLD | 10/22/2014 | 10/22/2014 |
| Note: Development Order for this permit is under a modification review. The Development Order modification consist of building footprint changes and revised elevations that will affect the building permit plans. | |||
| UD1 | COMPLETE | 10/22/2014 | 10/28/2014 |
| BLD | HOLD | 10/22/2014 | 10/23/2014 |
| Note: 1. Provide details for the penetration of the hallway floor/ceiling assembly by the floor drain. 2. Provide a detail for the 3 inch floor drain penetrations thru the tenent walls including how the notching or boring into the top plates is to be achieved. J. Hindman 986-3784. | |||
| FI1 | HOLD | 10/22/2014 | 10/23/2014 |
| Note: 1. Provide details for the penetration of the hallway floor/ceiling assembly by the floor drain. 2. Provide a detail for the 3 inch floor drain penetrations thru the tenent walls including how the notching or boring into the top plates is to be achieved. J. Hindman 986-3784. | |||
| ZON | HOLD | 09/02/2014 | 09/03/2014 |
| Note: 1. Provide executed Development Order. 2. Provide an executed access agreement. 3. Provide an updated site plan. 4. Correct the permit application to reflect the correct number of floors for this building. | |||
| BLD | HOLD | 09/02/2014 | 09/30/2014 |
| Note: 1. Provide floor and roof truss layouts from the roof truss engineering company. J. Hindman 986-3784. | |||
| FI1 | COMPLETE | 09/02/2014 | 09/25/2014 |
| UD1 | HOLD | 09/02/2014 | 09/11/2014 |
| Note: 26.7 PSI is not a reasonable level of service. The system pressure varies from 60 psi to 65psi. Booster pumps will likely be required for 3rd and 4th floors | |||
| BLD | HOLD | 07/22/2014 | 07/24/2014 |
| Note: 1. The set of plans submitted has 3 and 4 story details. The permit application is for a 3 story building. Provide a set of plans that corresponds to the building type and permit. 2. Provide a design with an NFPA 13 sprinkler system due to the area and height modification increase per 2010 FBC 506.3 and 903.3.1.1. 3. Provide an exterior wall design that complies with 2010 FBC table 601. A 3x4 wall can only support two floors and a roof/ceiling per2010 FBC table 2308.9.1. 4. Provide an exterior rated wall design that matches the U.L. rated system. U.L. 356 does not show 3x4 studs per U.L. and 2010 FBC 107.2.1. Additional comments may be required after the above comments are addressed. J. Hindman 986-3784. | |||
| ELEC | COMPLETE | 07/22/2014 | 07/22/2014 |
| ENGIN1 | COMPLETE | 07/22/2014 | 07/23/2014 |
| FI1 | HOLD | 07/22/2014 | 07/24/2014 |
| Note: 1. The set of plans submitted has 3 and 4 story details. The permit application is for a 3 story building. Provide a set of plans that corresponds to the building type and permit. 2. Provide a design with an NFPA 13 sprinkler system due to the area and height modification increase per 2010 FBC 506.3 and 903.3.1.1. 3. Provide an exterior wall design that complies with 2010 FBC table 601. A 3x4 wall can only support two floors and a roof/ceiling per2010 FBC table 2308.9.1. 4. Provide an exterior rated wall design that matches the U.L. rated system. U.L. 356 does not show 3x4 studs per U.L. and 2010 FBC 107.2.1. Additional comments may be required after the above comments are addressed. J. Hindman 986-3784. | |||
| MECH | COMPLETE | 07/22/2014 | 07/22/2014 |
| PLUM | COMPLETE | 07/22/2014 | 07/22/2014 |
| UD1 | HOLD | 07/22/2014 | 08/01/2014 |
| Note: Provide data showing the 3rd and 4th floors water service will function at a reasonable level of service | |||
| ZON | HOLD | 07/22/2014 | 07/22/2014 |
| Note: 1. Provide executed Development Order. 2. Provide an executed access agreement. 3. Provide an updated site plan. 4. Provide an updated address map. 5. Correct the permit application to reflect the correct number of floors for this building. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 05/27/2015 |
| REINSPECTION FEE | ¤40.00 | 05/27/2015 |
| REINSPECTION FEE | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| REVISION | ¤40.00 | 05/27/2015 |
| SURCHARGE FS 533.721 | ¤412.88 | 11/19/2014 |
| SURCHARGE - FS 468.631 | ¤412.88 | 11/19/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤2,027.57) | 11/19/2014 |
| ADMIN COMMERCIAL | ¤60.00 | 11/19/2014 |
| ELECTRIC FEE | ¤1,997.40 | 11/19/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤152.00) | 11/19/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤5,066.64 | 11/19/2014 |
| IMPACT FEE PARKS | ¤20,381.76 | 11/19/2014 |
| FIRE PLANS REVIEW | ¤338.39 | 11/19/2014 |
| IMPACT FEE TRANSPORTATION | ¤67,585.68 | 11/19/2014 |
| MECHANICAL FEE | ¤1,997.40 | 11/19/2014 |
| PERMIT FEE | ¤17,759.50 | 11/19/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤611.45) | 11/19/2014 |
| PLAN CHECK FEE | ¤3,713.35 | 11/19/2014 |
| PLUMBING FEE | ¤1,997.40 | 11/19/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤119,412.26 |