I want to search for...
Permit #2014080183
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00620-0220 |
| CONDITIONED SPACE: 2472 sqft |
| GARAGE: 627 sqft |
| OPENED PORCH (WITH ROOF) : 191 sqft |
| OPENED PORCH (WITH ROOF) : 122 sqft |
| Total Square Footage: 3412 sqft |
| Block: 00620 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: (904)296-1490 |
| Location Address: 61 WOODLAWN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/04/2014 |
| NOC: RECORDED |
| Applicant name: KENNETH WAYNE CAMPBELL JR |
| Owner: MARONDA HOMES INC OF FLORIDA |
|
Address 9700 PHILIPS HWY, STE 102 JACKSONVILLE, FL 32256 |
| Lot: 0220 |
| Contracted Stated Job Value: ¤96,868.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES INC. OF FLORIDA
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
6800 SOUTHPOINT PKWAY SUITE 300 JACKSONVILLE, FL 32216 |
CBC058803 (Exp: 08/31/2018) | 904-268-7730 | 904-268-7740 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
531 CODISCO WAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2018) | (407)333-2665 | (407)585-1002 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
JACK DOUGLAS LANIER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
485 COMMERCE WAY LONGWOOD , FL 32750 |
CCC058022 (Exp: 08/31/2026) | (321)441-2300 | (321)441-2313 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/24/2015 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 02/24/2015 | FINAL APPROVED | DSPENCER |
| ROW FINAL | 02/23/2015 | FINAL APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 02/23/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 2/23/2015 11:22:16 AM NEED OUTLET AT 2`` WALL SPACE ADJACENT TO KITCHEN, OUTLET NEEDS TO BE 6`` FROM OPENING LIVING ROOM. TWO OUTSIDE GABLES NEED TO BE EXTERIOR FINISHED. SOFFIT NEEDS TO BE COMPLETED AT PORCH. REAR PORCH SLIDER TRIM NEEDS TO BE COMPLETED. | |||
| ROW FINAL | 02/20/2015 | CANCELLED BY APPLICANT | GLALIMA |
| Note: THIS IS A REINSPECTION 2 / 20 / 2015 TOMY CALLED AND CANCELLED. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/19/2015 | APPROVED | FREODICA |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/18/2015 | Disapproved - NO FEE | FREODICA |
| Note: The grading elevations at the left side of the house show a low spot area that prevents the continuity of drainage flow to the front. | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 02/18/2015 | APPROVED | RGROSS |
| ROW FINAL | 02/18/2015 | CANCELLED BY APPLICANT | RGROSS |
| Note: Contaced at 7:30 am before arriving for the inspection. | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 02/06/2015 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| U - SEWER TIE IN | 01/30/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC - EARLY POWER | 01/27/2015 | APPROVED | JCOLASANTI |
| Note: Inspection Resulted at 1/27/2015 3:17:50 PM SPOKE WITH DALE FPL AT 3:15PM | |||
| U - SEWER TIE IN | 01/15/2015 | CANCELLED BY APPLICANT | DSPENCER |
| INSULATION | 12/22/2014 | APPROVED | DROCKWELL |
| LATH/BRICK/ WATER BARRIER | 12/22/2014 | APPROVED | DROCKWELL |
| ALL ROUGH | 12/16/2014 | APPROVED - AS NOTED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 12/16/2014 2:56:12 PM BEDROOM 3 SMOKE DET, NEEDS TO BE MOVED. WILL CHECK AT INSULATION. | |||
| ALL ROUGH | 12/15/2014 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 12/15/2014 1:12:30 PM STRAPPING OF ROMEX NEC.334.30 )WATER HEATER ELC. BOX NEEDS TO BE COMPLETED AND STRAPED. HANGING WIRE IN GARAGE. WIRES NEED TO BE 6`` FROM SCUDDLE OPENING IN GARAGE....NEC3210.23(A) BEDROOM TWO OUTLET MISSING AT ENTRANCE (2`` OF WALL SPACE.). SMOKE DETECTOR NEEDS TO BE 10`` FROM BEDROOM OPENING. (BEDROOM TWO) SMOKE DETECTORS NEED TO BE 3`` FROM FAN BLADES NFPA 72. NAIL PLATES ON ELECTRIC AT FOYER NEC.300.4 NOT READY CALL FOR REINSPECTION. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/04/2014 | APPROVED | JCOLASANTI |
| TIE BEAM / LINTEL | 11/20/2014 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 11/06/2014 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/06/2014 | APPROVED | RLEE |
| MONOLITHIC SLAB | 11/05/2014 | CANCELLED BY APPLICANT | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/04/2014 | APPROVED | JCOLASANTI |
| GRAVITY SEWER TEST | 11/04/2014 | APPROVED | JCOLASANTI |
| FOOTER | 10/13/2014 | APPROVED | JCOLASANTI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/19/2015 | 02/19/2015 |
| Note: Released By: FREODICA | |||
| SW1 | HOLD | 02/17/2015 | 02/18/2015 |
| Note: Held By: FREODICA final survey The grading elevations at the left side of the house show a low spot area that prevents the continuity of drainage flow to the front. | |||
| SW1 | COMPLETE | 11/06/2014 | 11/06/2014 |
| Note: Released By: RLEE foundation s | |||
| ELEC | COMPLETE | 08/20/2014 | 08/20/2014 |
| ELEC | HOLD | 08/18/2014 | 08/18/2014 |
| Note: 1. Provide wall receptacles at bedroom 2 and 3 between the doors and the closet doors. 2008 NEC 210.52. J. Hindman 986-3784. | |||
| ELEC | HOLD | 08/15/2014 | 08/15/2014 |
| Note: 1. Provide receptacle spacing per 2008 nec210.52. at bedrooms 2 and 3 next to the doors. J. Hindman 986-3784. | |||
| BLD | COMPLETE | 08/08/2014 | 08/11/2014 |
| ELEC | HOLD | 08/08/2014 | 08/11/2014 |
| Note: 1. Provide receptacle spacing per 2008 nec 210.52. J. Hindman 986-3784. | |||
| ENGIN1 | COMPLETE | 08/08/2014 | 08/13/2014 |
| MECH | COMPLETE | 08/08/2014 | 08/11/2014 |
| PLUM | COMPLETE | 08/08/2014 | 08/11/2014 |
| SW1 | COMPLETE | 08/08/2014 | 08/11/2014 |
| UD1 | COMPLETE | 08/08/2014 | 08/08/2014 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 08/08/2014 | 08/08/2014 |
| ZON | COMPLETE | 08/08/2014 | 08/11/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/25/2015 |
| REINSPECTION FEE | ¤40.00 | 02/25/2015 |
| NEW RESIDENTIAL INSPECTIONS | ¤626.00 | 09/04/2014 |
| SITE PLAN 20 | ¤20.00 | 09/04/2014 |
| SURCHARGE FS 533.721 | ¤22.72 | 09/04/2014 |
| SURCHARGE - FS 468.631 | ¤22.72 | 09/04/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/04/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 09/04/2014 |
| ADMIN FEE | ¤20.00 | 09/04/2014 |
| ELECTRIC FEE | ¤247.80 | 09/04/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.33) | 09/04/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤211.11 | 09/04/2014 |
| IMPACT FEE PARKS | ¤894.24 | 09/04/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/04/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 09/04/2014 |
| MECHANICAL FEE | ¤247.80 | 09/04/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤26.83) | 09/04/2014 |
| PLAN CHECK FEE | ¤125.20 | 09/04/2014 |
| PLUMBING FEE | ¤247.80 | 09/04/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,338.77 |