Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00620-0220
CONDITIONED SPACE: 2472 sqft
GARAGE: 627 sqft
OPENED PORCH (WITH ROOF) : 191 sqft
OPENED PORCH (WITH ROOF) : 122 sqft
Total Square Footage: 3412 sqft
Block: 00620
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: (904)296-1490
Location Address: 61 WOODLAWN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/04/2014
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC OF FLORIDA

Address

9700 PHILIPS HWY, STE 102

JACKSONVILLE, FL 32256

Lot: 0220
Contracted Stated Job Value: ¤96,868.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH H STRADA JR
Status Location Address State License Number Phone Fax
CANCEL

531 CODISCO WAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2018) (407)333-2665 (407)585-1002
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/24/2015 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 02/24/2015 FINAL APPROVED DSPENCER
ROW FINAL 02/23/2015 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 02/23/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 2/23/2015 11:22:16 AM NEED OUTLET AT 2`` WALL SPACE ADJACENT TO KITCHEN, OUTLET NEEDS TO BE 6`` FROM OPENING LIVING ROOM. TWO OUTSIDE GABLES NEED TO BE EXTERIOR FINISHED. SOFFIT NEEDS TO BE COMPLETED AT PORCH. REAR PORCH SLIDER TRIM NEEDS TO BE COMPLETED.
ROW FINAL 02/20/2015 CANCELLED BY APPLICANT GLALIMA
Note: THIS IS A REINSPECTION 2 / 20 / 2015 TOMY CALLED AND CANCELLED.
FINAL SURVEY (OFFICE USE ONLY) 02/19/2015 APPROVED FREODICA
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 02/18/2015 Disapproved - NO FEE FREODICA
Note: The grading elevations at the left side of the house show a low spot area that prevents the continuity of drainage flow to the front.
FINAL APRON (AFTER POUR/DRIVEWAY) 02/18/2015 APPROVED RGROSS
ROW FINAL 02/18/2015 CANCELLED BY APPLICANT RGROSS
Note: Contaced at 7:30 am before arriving for the inspection.
PRE-APRON (PRE-POUR/DRIVEWAY) 02/06/2015 APPROVED RGROSS
Note: READY TO POUR
U - SEWER TIE IN 01/30/2015 APPROVED DSPENCER
Note: THIS IS A REINSPECTION
ELECTRIC - EARLY POWER 01/27/2015 APPROVED JCOLASANTI
Note: Inspection Resulted at 1/27/2015 3:17:50 PM SPOKE WITH DALE FPL AT 3:15PM
U - SEWER TIE IN 01/15/2015 CANCELLED BY APPLICANT DSPENCER
INSULATION 12/22/2014 APPROVED DROCKWELL
LATH/BRICK/ WATER BARRIER 12/22/2014 APPROVED DROCKWELL
ALL ROUGH 12/16/2014 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 12/16/2014 2:56:12 PM BEDROOM 3 SMOKE DET, NEEDS TO BE MOVED. WILL CHECK AT INSULATION.
ALL ROUGH 12/15/2014 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 12/15/2014 1:12:30 PM STRAPPING OF ROMEX NEC.334.30 )WATER HEATER ELC. BOX NEEDS TO BE COMPLETED AND STRAPED. HANGING WIRE IN GARAGE. WIRES NEED TO BE 6`` FROM SCUDDLE OPENING IN GARAGE....NEC3210.23(A) BEDROOM TWO OUTLET MISSING AT ENTRANCE (2`` OF WALL SPACE.). SMOKE DETECTOR NEEDS TO BE 10`` FROM BEDROOM OPENING. (BEDROOM TWO) SMOKE DETECTORS NEED TO BE 3`` FROM FAN BLADES NFPA 72. NAIL PLATES ON ELECTRIC AT FOYER NEC.300.4 NOT READY CALL FOR REINSPECTION.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/04/2014 APPROVED JCOLASANTI
TIE BEAM / LINTEL 11/20/2014 APPROVED JCOLASANTI
MONOLITHIC SLAB 11/06/2014 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
FOUND SURVEY APPROVED (OFFICE) 11/06/2014 APPROVED RLEE
MONOLITHIC SLAB 11/05/2014 CANCELLED BY APPLICANT JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 11/04/2014 APPROVED JCOLASANTI
GRAVITY SEWER TEST 11/04/2014 APPROVED JCOLASANTI
FOOTER 10/13/2014 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 COMPLETE 02/19/2015 02/19/2015
Note: Released By: FREODICA
SW1 HOLD 02/17/2015 02/18/2015
Note: Held By: FREODICA final survey The grading elevations at the left side of the house show a low spot area that prevents the continuity of drainage flow to the front.
SW1 COMPLETE 11/06/2014 11/06/2014
Note: Released By: RLEE foundation s
ELEC COMPLETE 08/20/2014 08/20/2014
ELEC HOLD 08/18/2014 08/18/2014
Note: 1. Provide wall receptacles at bedroom 2 and 3 between the doors and the closet doors. 2008 NEC 210.52. J. Hindman 986-3784.
ELEC HOLD 08/15/2014 08/15/2014
Note: 1. Provide receptacle spacing per 2008 nec210.52. at bedrooms 2 and 3 next to the doors. J. Hindman 986-3784.
BLD COMPLETE 08/08/2014 08/11/2014
ELEC HOLD 08/08/2014 08/11/2014
Note: 1. Provide receptacle spacing per 2008 nec 210.52. J. Hindman 986-3784.
ENGIN1 COMPLETE 08/08/2014 08/13/2014
MECH COMPLETE 08/08/2014 08/11/2014
PLUM COMPLETE 08/08/2014 08/11/2014
SW1 COMPLETE 08/08/2014 08/11/2014
UD1 COMPLETE 08/08/2014 08/08/2014
Note: See comments in the general notes Keith King 386-9318009
URB COMPLETE 08/08/2014 08/08/2014
ZON COMPLETE 08/08/2014 08/11/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 02/25/2015
REINSPECTION FEE ¤40.00 02/25/2015
NEW RESIDENTIAL INSPECTIONS ¤626.00 09/04/2014
SITE PLAN 20 ¤20.00 09/04/2014
SURCHARGE FS 533.721 ¤22.72 09/04/2014
SURCHARGE - FS 468.631 ¤22.72 09/04/2014
STORM WATER PERMIT FEES ¤80.00 09/04/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 09/04/2014
ADMIN FEE ¤20.00 09/04/2014
ELECTRIC FEE ¤247.80 09/04/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 09/04/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 09/04/2014
IMPACT FEE PARKS ¤894.24 09/04/2014
IMPACT FEE SCHOOL ¤3,600.00 09/04/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 09/04/2014
MECHANICAL FEE ¤247.80 09/04/2014
3% PARKS IMPACT FEE CREDIT (¤26.83) 09/04/2014
PLAN CHECK FEE ¤125.20 09/04/2014
PLUMBING FEE ¤247.80 09/04/2014
Fees Total Due: ¤0.00 Total Paid: ¤9,338.77