I want to search for...
Permit #2014080362
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00070-0250 |
| CONDITIONED SPACE: 2040 sqft |
| GARAGE: 620 sqft |
| OPENED PORCH (WITH ROOF) : 344 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| Total Square Footage: 3092 sqft |
| Block: 00070 |
| Subdivision: 2185 - SECTION 7-FLORIDA PARK |
| Job Phone: (386)775-0171 |
| Location Address: 97 FORT CAROLINE LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/26/2014 |
| NOC: RECORDED |
| Applicant name: FRANK MICHAEL MILLER |
| Owner: SHINNECOCK PROPERTIES LLC |
|
Address 67 ISLAND ESTATES PKWY PALM COAST, FL 32137 |
| Lot: 0250 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
F-M BUILDER AND CONSTRUCTION SERVICES LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
613 PINEVIEW DRIVE ORANGE CITY, FL 32763 |
CBC022168 (Exp: 08/31/2022) | (386)775-0171 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32136 |
CAC048127 (Exp: 08/31/2018) | 386-445-5023 | 386-446-4614 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/16/2015 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 02/13/2015 | FINAL APPROVED | DSPENCER |
| BLD - BUILDING FINAL | 02/11/2015 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 2/11/2015 10:54:05 AM NEED TO HAVE ARC SHIELDS WHERE THERE IS MORE THAN 1/4" SPACE AT COMBUSTABLES CHECK AT MIRROR RECPTACLES..NEC 314.20 ..LIGHTING OUTLETS SHALL BE INSTALLED IN BED ROOMS NEC 210.70..ALSO AT GARAGE SIDE DOOR EXIT NEED TO HAVE SOD LOWERED TO ALLOW CONTINUOUS FLOW OF DRAINAGE | |||
| FINAL APRON (AFTER POUR/DRIVEWAY) | 02/11/2015 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| ROW FINAL | 02/11/2015 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/09/2015 | APPROVED | JHINDMAN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 02/05/2015 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED A FINAL SURVEY AND YOU NEED TO CHECK YOUR DRIVEWAY DETAIL '' YOUR CUTS ARE WRONG " SEE DRIVEWAY DETAIL. | |||
| ROW FINAL | 02/05/2015 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: ON RIGHT SIDE OF DRIVEWAY YOU NEED TO REMOVE SOD FROM EDGE OF ROAD BACK 15 ' FEET THEN FILL AS NEEDED AND MAKE A SWALE . NEED A FINAL SURVEY | |||
| U - SEWER TIE IN | 02/02/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC - EARLY POWER | 01/15/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 1/15/2015 2:07:18 PM CALLED FPL TO RELEASE POWER AT 145PM, SPOKE WITH SUSAN | |||
| GRAVITY SEWER TEST | 01/07/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 01/06/2015 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION READY TO POUR | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 12/31/2014 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: SEE DRIVEWAY DETAIL . FAILED REINSPECTION NEEDED | |||
| GRAVITY SEWER TEST | 12/19/2014 | CANCELLED BY APPLICANT | JCOLASANTI |
| U - SEWER TIE IN | 12/19/2014 | CANCELLED BY APPLICANT | MKRONENBERG |
| LATH/BRICK/ WATER BARRIER | 12/08/2014 | APPROVED | CMINI |
| INSULATION | 12/01/2014 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 11/25/2014 | Disapproved -FEE REQUIRED | CMINI |
| Note: Inspection Resulted at 11/25/2014 11:53:19 AM NOT READY FOR INSULATION INSPECTION, NO INSULATION INSTALLED AND NEED TO HAVE PENATRATIONS FIRE FOAMED | |||
| ALL ROUGH | 11/21/2014 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 11/21/2014 10:54:22 AM 5`` HEAD TEST ON DWV 2503.5.1..NEED TO INSTALL MISSING OUTLET PER PLAN IN HALLWAY BETWEEN BATH AND BD.RM..NEED TO REVISE PLAN BEFORE FIAL FOR CHANGE OF LOCATION OF AIR HANDLER..PENETRATIONS NEED TO BE SEALED WITH FIRE RATED FOAM RED OR ORANGE IN COLOR.. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/05/2014 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 10/24/2014 | APPROVED | CMINI |
| FOUND SURVEY APPROVED (OFFICE) | 10/20/2014 | APPROVED | JHINDMAN |
| MONOLITHIC SLAB | 10/08/2014 | APPROVED | CMINI |
| ELECTRIC TEMP POLE | 10/07/2014 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/06/2014 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/09/2015 | 02/09/2015 |
| Note: Released By: JHINDMAN final s | |||
| MECH | COMPLETE | 12/16/2014 | 12/17/2014 |
| Note: Revision- relocated AHU in garage. | |||
| PLUM | COMPLETE | 12/16/2014 | 12/17/2014 |
| Note: Revision- relocated water heater in garage. | |||
| SW1 | COMPLETE | 10/20/2014 | 10/20/2014 |
| Note: Released By: JHINDMAN | |||
| ZON | COMPLETE | 08/26/2014 | 08/26/2014 |
| ENGIN1 | COMPLETE | 08/21/2014 | 08/25/2014 |
| ELEC | COMPLETE | 08/21/2014 | 08/21/2014 |
| BLD | COMPLETE | 08/21/2014 | 08/21/2014 |
| ZON | HOLD | 08/21/2014 | 08/21/2014 |
| Note: 1. Explain what textured areas on front of elevation consist of (material, etc) in order to determine if they comply with Land Development Code. 2. Elevations must show that banding wraps the corners of the house for at least two feet. Cannot just write information on correction form. | |||
| BLD | HOLD | 08/14/2014 | 08/15/2014 |
| Note: 1. Provide a 2-8 bathroom door per 2010 FBC R 320. 2. Provide a roof truss layout from the truss engineer. 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 08/14/2014 | 08/15/2014 |
| Note: 1. Provide service and feeder conductor material type. (Cu or Al) on service riser diagram. per 2008 nec 310.15. J. Hindman 986-3784. | |||
| ENGIN1 | HOLD | 08/14/2014 | 08/14/2014 |
| Note: Provide benchmark per technical manual. Scott Bombardier 986-3756 | |||
| MECH | COMPLETE | 08/14/2014 | 08/14/2014 |
| PLUM | COMPLETE | 08/14/2014 | 08/14/2014 |
| SW1 | COMPLETE | 08/14/2014 | 08/14/2014 |
| UD1 | COMPLETE | 08/14/2014 | 08/15/2014 |
| Note: See comments in the general notes Keith King 386-9318009 | |||
| URB | COMPLETE | 08/14/2014 | 08/18/2014 |
| Note: Prior to construction all saved trees are required to have a barricade | |||
| ZON | HOLD | 08/14/2014 | 08/15/2014 |
| Note: 1. Provide Color Code and LRV for exterior paint colors. 2. Identify textured areas on front elevation. 3. Stucco banding must wrap corners for at least two feet. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/16/2015 |
| REINSPECTION FEE | ¤40.00 | 02/16/2015 |
| REINSPECTION FEE | ¤40.00 | 02/16/2015 |
| REINSPECTION FEE | ¤40.00 | 02/16/2015 |
| REINSPECTION FEE | ¤40.00 | 02/16/2015 |
| REVISION | ¤40.00 | 02/16/2015 |
| REVISION | ¤40.00 | 02/16/2015 |
| SITE PLAN 20 | ¤20.00 | 08/26/2014 |
| SURCHARGE FS 533.721 | ¤20.01 | 08/26/2014 |
| SURCHARGE - FS 468.631 | ¤20.01 | 08/26/2014 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/26/2014 |
| 3% TRANS IMPACT FEE CREDIT | (¤90.51) | 08/26/2014 |
| NEW RESIDENTIAL INSPECTIONS | ¤540.00 | 08/26/2014 |
| ADMIN FEE | ¤20.00 | 08/26/2014 |
| ELECTRIC FEE | ¤222.00 | 08/26/2014 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.33) | 08/26/2014 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤211.11 | 08/26/2014 |
| IMPACT FEE PARKS | ¤894.24 | 08/26/2014 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 08/26/2014 |
| IMPACT FEE TRANSPORTATION | ¤3,017.05 | 08/26/2014 |
| MECHANICAL FEE | ¤222.00 | 08/26/2014 |
| 3% PARKS IMPACT FEE CREDIT | (¤26.83) | 08/26/2014 |
| PLAN CHECK FEE | ¤108.00 | 08/26/2014 |
| PLUMBING FEE | ¤222.00 | 08/26/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,352.75 |