I want to search for...

Permit #2014090389

Permit Details

Status: COED

Parcel Id: 42-10-30-3210-00000-2690
CONDITIONED SPACE: 2922 sqft
GARAGE: 833 sqft
SCREEN PORCH (SOLID ROOF) : 760 sqft
OPENED PORCH (WITH ROOF) : 90 sqft
Total Square Footage: 4605 sqft
Block: 00000
Subdivision: 2094 - Conservatory at Hammock Beach
Job Phone: (386) 446-5850
Location Address: 514 SWEETGUM LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/24/2014
NOC: RECORDED
Applicant name: CHARLES DALLAS RINEK
Owner: TILLMAN, JOHN L JR & KATHRYN

Address

747 BRIDGECREEK COURT

LAKE FOREST, FL 32771

Lot: 2690
Contracted Stated Job Value: ¤37,500.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CHARLES RINEK CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 352502

Palm Coast, FL 32137

CGC046080 (Exp: 08/31/2026) (386) 446-5850 (386)445-9992

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156
PHILIP ALAN KENOVICH
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 1470

HOLLY HILL, FL 32117

LG270 (Exp: 08/31/2026) (386)672-2507

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/24/2015 FINAL APPROVED MBACON
BLD - BUILDING FINAL 06/22/2015 FINAL APPROVED JCOLASANTI
ROW FINAL 06/19/2015 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
FINAL APRON (AFTER POUR/DRIVEWAY) 06/17/2015 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION WILL CKECK FINAL SURVEY AT FINAL R.O.W. INSPECTION
ROW FINAL 06/17/2015 CANCELLED BY APPLICANT GLALIMA
Note: WORKING ON SOD . EROSION AT LAKE, ENVIRONMENTAL ISSUS . ALL IS GOOD.
FINAL SURVEY (OFFICE USE ONLY) 06/17/2015 APPROVED DREWIS
PRE-APRON (PRE-POUR/DRIVEWAY) 05/29/2015 APPROVED GLALIMA
Note: THIS IS A REINSPECTION READY FOR PAVERS
FINAL APRON (AFTER POUR/DRIVEWAY) 05/28/2015 Disapproved -FEE REQUIRED GLALIMA
Note: COULD NOT PERFORM THIS INSPECTION BECAUSE YOU HAVE NO DRIVEWAY TO FINAL .
PRE-APRON (PRE-POUR/DRIVEWAY) 05/14/2015 PARTIALLY APPROVED GLALIMA
PRE-APRON (PRE-POUR/DRIVEWAY) 05/13/2015 CANCELLED BY INSPECTOR GLALIMA
Note: I HAVE BEEN IN THE CONSERVATORY 15 TO 25 TIMES , TODAY I WENT TO DO A PRE-POUR DRIVEWAY I GAVE HER MY CITY I.D FROM INSIDE MY '' CITY TRUCK . I MADE SOME CALLS AND I WILL GIVE MY LICENSE TOMORROW FOR THE 4 th OR 6 th TIME. . STOPING AT CONSERVATORY OFFICE TO BE PUT ON LIST
ELECTRIC - EARLY POWER 05/11/2015 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 5/11/2015 2:36:03 PM CALLED FPL TO RELEASE POEWER
INSULATION 03/05/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 03/03/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 3/3/2015 12:58:41 PM NEED TO FIRE BLOCK BOTTOM OF FIREPLACE VENT WHERE ENTERING BUILD OUT TO ATTIC.
LATH/BRICK/ WATER BARRIER 03/02/2015 APPROVED CMINI
ALL ROUGH 02/26/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ALL ROUGH 02/24/2015 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 2/24/2015 1:17:09 PM MC STRAPPING. EVERY 4-1/2`` IN ATTIC AND AT FIREPLACE CONNECTION NEEDS STRAPPING....NEC 330.30 ...ACCESS DOOR FOR FIREPLACE SHUT OFF VALVE? NEED TO MAKE UP BOXES PROPERLY AT GARAGE CARRIGE LIGHTS..MAKE UP AND GROUND BOXES AT ALARM PANELS..ELEC BONDING OF GAS PIPE.PROPERLY,. NEC.250.1043B..NEED PRESSURE GAUGE ON GAS LINE...FBC.G2417.BONDING SCREW MISSING ON PANEL 1..CHECK PHASING ON WHITE CONDUCTORS, NEED TO PHASE HIGHER UP.. BOX NEEDED ON WIRE AT LANAI IN CEILING..5`` HEAD PRESSURE ON DWV ..FBC 312..
ALL ROUGH 02/19/2015 PARTIALLY APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION PER CONTRACTOR Inspection Resulted at 2/19/2015 2:50:06 PM APPROVED SLIDERS AND SWING DOORS AT REAR OF RESIDENCE.
U - SEWER TIE IN 02/05/2015 APPROVED DSPENCER
Note: THIS IS A REINSPECTION per contractor
U - SEWER TIE IN 02/04/2015 Disapproved -FEE REQUIRED DSPENCER
Note: Inspection Resulted at 2/4/2015 11:20:26 AM DOES NOT MEET PALM COAST UTILITY STANDARDS HAS A VERTICAL DROP.
ALL ROUGH 02/04/2015 Disapproved -FEE REQUIRED CMINI
Note: partial windows garage door/sliding Inspection Resulted at 2/4/2015 2:01:37 PM ONLY LOOKED AT DOORS AND WINDOWS, SLIDERS TRACK NOT TO PRODUCT APPROVAL SHEET
GRAVITY SEWER TEST 02/04/2015 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/30/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/18/2014 PARTIALLY APPROVED JCOLASANTI
Note: Inspection Resulted at 12/18/2014 2:06:44 PM THIS INSPECTION WAS FOR ROOF ONLY. NEED TO CALL IN FOR BRACES, TIES AND ENGINEERING.
ELECTRIC - EARLY POWER 12/09/2014 PARTIALLY APPROVED JCOLASANTI
Note: Inspection Resulted at 12/9/2014 2:49:19 PM THIS SHOULD HAVE BEEN A TUG INSPECTION. EARLY POWR WILL NEED TO BE CALLED IN WHEN READY. SPOKE WITH SUSAN @FPL TO RELEASE POWER 2:30PM
TIE BEAM / LINTEL 11/21/2014 APPROVED CMINI
Note: PER CONTRACTOR
FOUND SURVEY APPROVED (OFFICE) 11/07/2014 APPROVED JHINDMAN
MONOLITHIC SLAB 10/22/2014 APPROVED CMINI
Note: per contractor
PLUMBING 1ST ROUGH UNDERGROUND 10/16/2014 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION PER CONTRACTOR
PLUMBING 1ST ROUGH UNDERGROUND 10/15/2014 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 10/15/2014 2:12:16 PM NO PLUMBING RISER SHEET ON SITE AT TIME OF INSPECTION.

Review History

Department Status Date In Date Out
SW1 COMPLETE 06/17/2015 06/17/2015
Note: Released By: DREWIS final s
SW1 COMPLETE 11/07/2014 11/07/2014
Note: Released By: JHINDMAN foundation s
BLD COMPLETE 10/29/2014 10/31/2014
ELEC COMPLETE 09/23/2014 09/23/2014
BLD COMPLETE 09/23/2014 09/23/2014
BLD HOLD 09/16/2014 09/22/2014
Note: Provide Florida Product Approval Number or NOA for front door for energy and wind testing. Provide complete installation plans for iron front door.
ELEC HOLD 09/16/2014 09/22/2014
Note: 1. Provide gfci protection on all exterior receptacles 2008 NEC 210.8. 2. Provide gfci receptacle at bathroom 3. J. Hindman 986-3784.
ENGIN1 COMPLETE 09/16/2014 09/17/2014
Note: No swale plan required.
MECH COMPLETE 09/16/2014 09/22/2014
PLUM COMPLETE 09/16/2014 09/22/2014
SW1 COMPLETE 09/16/2014 09/22/2014
UD1 COMPLETE 09/16/2014 09/17/2014
Note: See comment in general notes Danny Spencer 386-569-9082
URB COMPLETE 09/16/2014 09/18/2014
ZON COMPLETE 09/16/2014 09/17/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/24/2015
REINSPECTION FEE ¤40.00 06/24/2015
REINSPECTION FEE ¤40.00 06/24/2015
REINSPECTION FEE ¤40.00 06/24/2015
REINSPECTION FEE ¤40.00 06/24/2015
REINSPECTION FEE ¤40.00 06/24/2015
NEW RESIDENTIAL INSPECTIONS ¤788.00 09/24/2014
SITE PLAN 20 ¤20.00 09/24/2014
SURCHARGE FS 533.721 ¤27.82 09/24/2014
SURCHARGE - FS 468.631 ¤27.82 09/24/2014
STORM WATER PERMIT FEES ¤80.00 09/24/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 09/24/2014
ADMIN FEE ¤20.00 09/24/2014
ELECTRIC FEE ¤296.40 09/24/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 09/24/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 09/24/2014
IMPACT FEE PARKS ¤894.24 09/24/2014
IMPACT FEE SCHOOL ¤3,600.00 09/24/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 09/24/2014
MECHANICAL FEE ¤296.40 09/24/2014
3% PARKS IMPACT FEE CREDIT (¤26.83) 09/24/2014
PLAN CHECK FEE ¤157.60 09/24/2014
PLUMBING FEE ¤296.40 09/24/2014
Fees Total Due: ¤0.00 Total Paid: ¤9,849.17