I want to search for...

Permit #2014100482

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-1320
CONDITIONED SPACE: 4074 sqft
GARAGE: 1033 sqft
OPENED PORCH (WITH ROOF) : 705 sqft
OPENED PORCH (WITH ROOF) : 81 sqft
Total Square Footage: 5893 sqft
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: 386-947-4481
Location Address: 3 TURKEY OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/12/2014
NOC: RECORDED
Applicant name: ERIC CHRISTOPHER OLSEN
Owner: THOMAS, WALTER & ERLENE H

Address

1205 PINE TREE DRIVE

LAKE VILLA, IL 60046

Lot: 132
Contracted Stated Job Value: ¤592,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

OLSEN CUSTOM HOMES AND CONSULTING INC
Status Location Address State License Number Phone Fax
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

CGC1508852 (Exp: 08/31/2026) 386-947-4481 (386)947-4484

Sub Contractors

BENJAMIN EDWARD SMITH
Status Location Address State License Number Phone
CANCEL

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13004288 (Exp: 08/31/2016) 386-265-2687
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
JOHN BRADLEY WINFREY JR
Status Location Address State License Number Phone Fax
ACTIVE

1685 S. CLARA AVE

Deland, FL 32720

CFC054901 (Exp: 08/31/2026) 386-734-0154 386-734-2751
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 06/10/2015 FINAL APPROVED MBACON
BLD - BUILDING FINAL 06/05/2015 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/04/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 6/4/2015 10:18:29 AM NEED TO HAVE FINAL APPROVED SURVEY ON JOB SITE..NEED TO REMOVE CONSTRUCTION DEBRIS FROM PROPERTY(PALLETTS AND EXTRA GRASS ETC) .. COULD NOT LOCATE 2ND AHU, IF IN ATTIC NEED TO HAVE (NOTICE TO HOMEH OWNER LETTER) POSTED ON ELECTRIC PANEL..FBC.M 1305.1.3.2
FINAL SURVEY (OFFICE USE ONLY) 06/03/2015 APPROVED FREODICA
U - SEWER TIE IN 06/01/2015 APPROVED MBACON
FINAL APRON (AFTER POUR/DRIVEWAY) 05/18/2015 APPROVED RGROSS
ROW FINAL 05/18/2015 APPROVED RGROSS
PRE-APRON (PRE-POUR/DRIVEWAY) 04/29/2015 APPROVED - AS NOTED GLALIMA
Note: FRIST PART OF THE INSPECTIONS NO PAVERBASE ON SITE OR IN PLACE . ANY ISSUE CALL GARY 585-0287
PRE-APRON (PRE-POUR/DRIVEWAY) 04/14/2015 APPROVED - AS NOTED GLALIMA
Note: THIS IS A REINSPECTION SEE PINK PAINT '' NEED TO CUT OUT DAMAGED STREET GUTTER . READY TO POUR
PRE-APRON (PRE-POUR/DRIVEWAY) 04/13/2015 Disapproved -FEE REQUIRED GLALIMA
Note: NO SURVEY OR PERMIT PACKAGE . RE-INSPECTION NEEDED '' FAILED''
ELECTRIC - EARLY POWER 04/06/2015 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 4/6/2015 3:18:55 PM CALLED FPL TO RELEASE FOR FINAL
INSULATION 02/25/2015 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 02/23/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 02/23/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 02/20/2015 CANCELLED BY APPLICANT DROCKWELL
ALL ROUGH 02/20/2015 CANCELLED BY APPLICANT DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/12/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING 02/11/2015 APPROVED CMINI
TRACK BOLT 02/11/2015 APPROVED CMINI
WINDOW FASTENING 02/11/2015 APPROVED CMINI
WALL SHEATHING 02/11/2015 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/11/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 2/11/2015 2:46:07 PM STRAPPING MISSING.
ELECTRIC-TUG 02/06/2015 APPROVED DROCKWELL
TIE BEAM / LINTEL 01/08/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 01/07/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 1/7/2015 2:11:25 PM PLANS CALL FOR STEEL IN POWER BOXES TO BE INSTALLED TOP AND BOTTOM-CURRENTLY INSTALLED SIDE BY SIDE/ EXTEND PLUMBING VENT THRU LINTLE RIGHT SIDE WALL
FOOTER 12/31/2014 APPROVED - AS NOTED CMINI
Note: pool footers Inspection Resulted at 12/31/2014 1:21:24 PM FOOTER FOR REAR COLUMNS
ELEV CERT-FOUNDATION APPROVAL 12/31/2014 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 12/30/2014 APPROVED FREODICA
MONOLITHIC SLAB 12/16/2014 APPROVED CMINI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 12/15/2014 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 12/15/2014 1:19:39 PM SLEEVE WATER LINES THRU FOOTERS WITH PIPE 2X LARGER PER FBC-PLUMBING. 8 SEPARATE LOCATIONS
PLUMBING 1ST ROUGH UNDERGROUND 12/05/2014 APPROVED CMINI
GRAVITY SEWER TEST 12/05/2014 APPROVED CMINI

Review History

Department Status Date In Date Out
BLD COMPLETE 06/08/2015 06/09/2015
Note: Released By: JHINDMAN
PLFM COMPLETE 06/05/2015 06/08/2015
SW1 COMPLETE 06/03/2015 06/03/2015
Note: Released By: FREODICA
PLFM HOLD 06/02/2015 06/04/2015
Note: Although you provided the plans for anchoring the tanks and the corrected elevation certificate, the calculations were not included. Please provide the calculation sheet for buoyancy forces meeting the requirements in FEMA Utilities 348 Section 3.2.3.1
PLFM HOLD 05/27/2015 05/28/2015
Note: In Section A3 of the 05-18-15 sealed elevation certificate, the lot # and Tax ID# are for lot 129. The project is located on lot 132. In addition, revisit the provided Map Book and Page information to ensure it is accurate. Correct and resubmit and amended elevation certificate with this section corrected.
PLFM HOLD 05/22/2015 05/26/2015
Note: Although you provided the plans for anchoring the tanks the calculations were not included. Please provide the calculation sheet for buoyancy forces.
PLFM HOLD 05/20/2015 05/20/2015
Note: 1. Provide plan showing the anchoring of the tank demonstrating that it will counteract buoyancy forces. 2. Provide sealed calculation sheet of buoyancy forces.
BLD COMPLETE 05/18/2015 05/19/2015
ZON COMPLETE 05/18/2015 05/19/2015
SW1 HOLD 05/18/2015 05/18/2015
Note: Held By: JHINDMAN FINAL SURVEY 1. Provide lot drainage that complies with the approved subdivion grading plan.
ZON HOLD 02/10/2015 02/10/2015
Note: Need site plan with location, dimensions and setbacks of UG LP tank. Also will need elevation certificate for UG LP tank as this lot is in a flood zone
BLD HOLD 02/06/2015 02/09/2015
Note: 1. Provide floor plan showing the gas piping and location of all appliances served by propane gas to match with gas riser diagram per 2010 FBC 107.2.1. 2. Provide site plan showing the location of 250 gal underground propane tank with set setback dimensions from property lines per 2010 FBC 107.2.1.
PLFM COMPLETE 12/30/2014 12/31/2014
SW1 COMPLETE 12/30/2014 12/30/2014
Note: Released By: FREODICA foundation s
BLD COMPLETE 12/19/2014 12/22/2014
PLUM COMPLETE 11/07/2014 11/07/2014
URB COMPLETE 11/07/2014 11/10/2014
PLUM HOLD 11/03/2014 11/03/2014
Note: Submitted correction on sanitary riser diagram does not show the lavatory and shower at the pool bath and the riser diagram shall have signature and license number of plumbing contractor per 2010 FBC 107.2.1.
URB HOLD 11/03/2014 11/04/2014
Note: Need the type of sod being installed indicated on the landscape plan.
PLFM COMPLETE 10/22/2014 10/24/2014
BLD COMPLETE 10/20/2014 10/21/2014
ELEC COMPLETE 10/20/2014 10/26/2014
ENGIN1 COMPLETE 10/20/2014 10/20/2014
Note: No swale plan required.
MECH COMPLETE 10/20/2014 10/21/2014
PLUM HOLD 10/20/2014 10/21/2014
Note: 1. Sanitary riser diagram does not match with floor plan. Laundry tub and lavatory in master bath are missing on riser diagram. Coordinate for clarity per 2010 FBC 107.2.1. 2. The water closet in master bath shall be vented to comply with 2010 FBCR P3105.1.
SW1 COMPLETE 10/20/2014 10/20/2014
UD1 COMPLETE 10/20/2014 10/21/2014
Note: See comment in general notes Danny Spencer 386-386-2640
URB HOLD 10/20/2014 10/27/2014
Note: Need to indicate the type of sod being installed. Need to submit an irrigation plan using the design standards set in the technical manual pages 41 and 42
ZON COMPLETE 10/20/2014 10/22/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/04/2015
REINSPECTION FEE ¤40.00 06/04/2015
REVISION ¤40.00 06/04/2015
REINSPECTION FEE ¤40.00 04/02/2015
REINSPECTION FEE ¤40.00 04/02/2015
REINSPECTION FEE ¤40.00 04/02/2015
REVISION ¤40.00 04/02/2015
NEW RESIDENTIAL INSPECTIONS ¤1,184.00 11/12/2014
SITE PLAN 20 ¤20.00 11/12/2014
SURCHARGE FS 533.721 ¤40.30 11/12/2014
SURCHARGE - FS 468.631 ¤40.30 11/12/2014
STORM WATER PERMIT FEES ¤80.00 11/12/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 11/12/2014
ADMIN FEE ¤20.00 11/12/2014
ELECTRIC FEE ¤415.20 11/12/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 11/12/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 11/12/2014
IMPACT FEE PARKS ¤849.24 11/12/2014
IMPACT FEE SCHOOL ¤3,600.00 11/12/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 11/12/2014
MECHANICAL FEE ¤415.20 11/12/2014
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/12/2014
PLAN CHECK FEE ¤236.80 11/12/2014
PLUMBING FEE ¤415.20 11/12/2014
Fees Total Due: ¤0.00 Total Paid: ¤10,702.08