I want to search for...
Permit #2014100766
Permit Details
Status: COED
| Parcel Id: 41-11-31-4975-00000-0010 |
| Total Square Footage: 0 sqft |
| Block: 00000 |
| Subdivision: - |
| Job Phone: 727-938-9719 |
| Location Address: 250 PALM COAST PKWY NE |
| Type: CSD - COMMERCIAL SITE DEVELOPMENT |
| Issue Date: 11/05/2014 |
| NOC: RECORDED |
| Applicant name: MICHAEL S BEAUSIR |
| Owner: BRANCH PROPERTIES, LLC |
|
Address 3340 PEACHTREE ROAD NE, SUITE 600 ATLANTA, GA 30326 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤48,000.00 |
| Job Description: BUILDING A-1, A-2, DEMO ISLAND WALK - STAGE 1 & 2 (SHEET 42 - 43 OF APPROVED CIVIL PLANS) |
| Type: CN |
Contractor
HAWKINS CONSTRUCTION INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1430 L AND R INDUSTRIAL BLVD TARPON SPRINGS, FL 34689 |
CGC061198 (Exp: 08/31/2018) | 727-938-9719 | 727-938-3208 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL SURVEY (COMM - OFFICE USE ONLY) | 09/29/2015 | APPROVED - AS NOTED | WBUTLER |
| Note: THIS IS A REINSPECTION 9/29/15 LANDSCAPE IRRIGATION AS-BUILTS APPROVED; HOWEVER, AWAITING MINOR REVISIONS TO BE PROVIDED TO THE CITY ON THE NEXT PERMIT PHASE OF DEVELOPMENT PRIOR TO APPROVAL OF THE NEXT PHASE/STAGE. | |||
| FINAL INSPECTION | 09/29/2015 | FINAL APPROVED | CMINI |
| LDSC- LANDSCAPE FINAL | 09/28/2015 | APPROVED | WBUTLER |
| Note: PER CONTRACTOR 9/28/15 Just some very minor sodding work to be completed and the repair of landscape where a fiber optic directional bore occurred today. Will be inspected at the next phase final inspection. Bill Butler | |||
| U - UTILITY COMMERCIAL FINAL | 09/21/2015 | APPROVED | DSPENCER |
| BLD - ADA COMPLIANT | 09/21/2015 | APPROVED | CMINI |
| LDSC- SUBSTANTIAL COMPLETE (OFFICE USE) | 09/17/2015 | APPROVED - AS NOTED | WBUTLER |
| Note: Permit Number 2014100766 9-17-15 1. The palm trees have not been staked as shown on the approved plan. The contractor indicated that he did not feel they needed to be staked. This is a decision that the project landscape architect needs to approve and if approved, he needs to remove all staking details from the as-built plan submittal. Otherwise, the trees need to be staked per the approved plan. 2. Automatic flush plugs still need to be installed in 6" valve boxes. This is all per City regulations for drip irrigation. 3. Mulch to be removed from touching the trunks of all trees and stems of all shrubs. 4. Need to plant Sabal palms where existing Sabal palms previously existed, but were mistakenly removed. One exception is the one island in the front of the storefronts that had 4, but a grouping of 3 meets code. 5. Mulch the planter bed between the road and the buildings sidewalk where the Hawkins Construction office is now located. 6. The low natural area where the two large specimen trees were saved needs to be cleaned out of weeds, construction debris and excess dirt, then mulched. 7. Mulch the east end of the entrance median on Old Kings Road. 8. At the exit road onto Old Kings Road, need to remove one Sabal palm that was shown to be removed from under the power lines. Need to also plant the juniper and irrigate per the plans. The pine trees shown on the plan to be removed can remain. 9. Mulch the disturbed shrubbery bed in the front and on the north side of Salsa's building. 10. Need to add the shrubs and irrigation to the rear of the Salsa's building per the approved plans. 11. Make sure the Solar Sync module gets put on the controller and also need a card in the controller that indicates what zone irrigates what area of the site. Note which zones are drip, bubblers or spray. 12. Need Bahia sod on the north side of the exit lane onto Old Kings Road as well as the area on the north side of the sidewalk. Sod also needed west of the curbed access road going to Salsa's restaurant. Other area needing sod is in the buffer along the south side of the road that is on the north side of the site. 13. Existing tree in the south end of the tree well in the parking lot has a broken branch hanging down that needs to be pruned off. 14. Landscape and irrigation as-built plans for phase 1 must be submitted and approved prior to calling for the final inspection. As-builts to include: a) Measurements from two fixed points for all valve boxes, wire splice boxes, and flush valves for drip irrigation. b) Any deviation in tree or plant location that is more than 5' from location on plan. d) Show any added or substituted plants or trees and add them to the plant list with size and spacing. e) Need two copies of signed and sealed plans, including the detail sheets and one CD copy of the landscape and irrigation plans. | |||
| LDSC- LANDSCAPE FINAL | 09/17/2015 | CANCELLED BY INSPECTOR | WBUTLER |
| Note: Cannot call in the final before the as-builts have been submitted and approved. | |||
| TRAFFIC SIGNAGE/PAVEMENT MARKING FINAL | 09/16/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 9/16/2015 2:46:37 PM 1) ALL NON-HANDICAP SIGNS NEED TO BE A MINIMUM OF 72 INCHES FROM THE BASE TO THE BOTTOM OF THE SIGN.HANDICAP SIGNS NEED TO BE 7' AT THE BOTTOM OF SIGNS THERE WERE SIGNS THAT DID NOT MEET THE MINIMUM HIEGHT REQUIREMENT. 2) AT THE SPINE ROAD INTERSECTION EAST OF OLD KINGS ROAD, PLEASE PULL THE CURB BACK 10 FEET TO ALLOW FOR BETTER TRUCK MOVEMENTS AND UTILIZE TYPE A MOUNTABLE CURB ON THE END POINT TO MINIMIZE DESTRUCTION OF THE CURB. 3) A CROSSWALK IS MISSING AT THE SPINE ROAD INTERSECTION EAST OF OLD KINGS ROAD ON THE NORTH APPROACH. PLEASE EXAMINE THE PLANS AS I BELIEVE THAT WAS SUPPOSED TO BE STAMPED ASPHALT. 4) AT THE SPINE ROAD INTERSECTION EAST OF OLD KINGS ROAD, THE WALK SIGN DIRECTLY ADJACENT TO THE STOP SIGN IS NOT NEEDED AS DRIVERS ARE REQUIRED TO STOP AT THE STOP BAR TO ALLOW PEDESTRIANS TO WALK. THESE ITEMS WILL BE CHECKED ON THE NEXT PHASE. per sean Castillo the traffic engineer for the city of Palm Coast (386)986-4758 | |||
| U-WATER METER INSTALLATION/VERIFICATION | 09/16/2015 | APPROVED | DSPENCER |
| UC-SUBSTANTIAL WALK-THRU | 09/16/2015 | APPROVED | DSPENCER |
| Note: Inspection Resulted at 9/16/2015 3:57:02 PM PUNCH LIST HAS BEEN GENERATED FOR CORRECTIONS TO BE MADE BEDORE UTILITY FINAL INSPECTION IS PERFORMED | |||
| FINAL GRADE PRIOR TO SOD | 09/15/2015 | APPROVED - AS NOTED | GLALIMA |
| Note: THIS IS A REINSPECTION SEE FINAL GRADE INSPECTION STAGE 1 PERFORMED ON SEPT, 15 2015 | |||
| FINAL DRAINAGE | 09/15/2015 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION MISSING SOD AND NO FINAL SURVEY . THIS ''FINAL GRADE INSPECTION IS FOR STAGE 1 AND WHEN STAGE 2 IS CALLED IN FOR INSPECTION STAGE 1 WILL BE RE-INSPECTED ''' DO UNDERSTAND THAT AT THE FINAL STAGE 4 YOU WILL HAVE TO HAVE A FULL SURVEY . ANY ISSUES CALL GARY LALIMA 386-586-0287 | |||
| LDSC-LOCATE BACKFLOW PREVENTOR OR PAD/ ELEC TRANS | 09/14/2015 | APPROVED | WBUTLER |
| LDSC-SITE LIGHT STAKE LOCATE | 09/14/2015 | APPROVED | WBUTLER |
| FINAL SURVEY (COMM - OFFICE USE ONLY) | 09/14/2015 | CANCELLED BY APPLICANT | BBEMBRY |
| FINAL GRADE | 09/11/2015 | CANCELLED BY APPLICANT | CMINI |
| Note: Inspection Resulted at 9/15/2015 3:07:39 PM NEED FINAL SURVEY APPROVED | |||
| FINAL GRADE PRIOR TO SOD | 09/11/2015 | CANCELLED BY APPLICANT | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| BLD - SITE LIGHTING-CONDUCTORS/CONNECTORS | 09/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/3/2015 1:40:25 PM COMPLETE | |||
| BLD - SITE LIGHTING EXTERIOR MOUNTED | 09/03/2015 | APPROVED | RMARTIN |
| FINAL DRAINAGE | 09/03/2015 | CANCELLED BY APPLICANT | CMINI |
| Note: Inspection Resulted at 9/3/2015 1:40:23 PM NEED AS-BUILT SURVEY APPROVED | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-WATER SERVICE INSTALLATION | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 09/03/2015 | APPROVED | DSPENCER |
| U-GRAVITY SEWER INSTALL/TESTING | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-REUSE MAIN INSTALL/TESTING | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-WATER MAIN DISINFECTION | 09/03/2015 | APPROVED | DSPENCER |
| U-WATER MAIN DISINFECTION SAMPLING | 09/03/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| ASPHALT PRE-PLACEMENT | 09/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/3/2015 1:40:24 PM COMPLETE | |||
| DRAINAGE STRUCTURE PLACEMENT | 09/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/3/2015 1:40:24 PM COMPLETE | |||
| DRAINAGE PIPE PLACEMENT | 09/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 9/3/2015 3:04:45 PM COMPLETE | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 09/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 9/3/2015 1:40:25 PM COMPLETE | |||
| BLD - SITE STRUCTURE-RETAINING WALL | 09/02/2015 | APPROVED | CMINI |
| BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS | 09/02/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 09/02/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| LDSC-PRE-PLANTING TREE QUALITY | 08/28/2015 | APPROVED | WBUTLER |
| FINAL GRADE PRIOR TO SOD | 08/28/2015 | CANCELLED BY APPLICANT | CMINI |
| BLD - SITE LIGHTING-CONDUCTORS/CONNECTORS | 08/28/2015 | PARTIALLY APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/28/2015 3:07:56 PM STILL NEED WIRING ON OLD KINGS MARQUE/SIGN | |||
| BLD - UNDERGROUND SITE LIGHTING CONDUITS | 08/28/2015 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| BLD - SITE LIGHTING-PLACEMENT/FOUNDATION | 08/28/2015 | APPROVED | RMARTIN |
| ASPHALT STRIPING | 08/11/2015 | CANCELLED BY INSPECTOR | DROCKWELL |
| Note: Inspection Resulted at 8/11/2015 2:41:14 PM STRIPING INCONSISTANT ONLY VARIOUS AREA``S | |||
| ASPHALT PRE-PLACEMENT | 08/11/2015 | PARTIALLY APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/11/2015 2:41:14 PM ENTRANCE APRON BUILD A-1. | |||
| DRAINAGE PIPE PLACEMENT | 08/07/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/7/2015 12:05:47 PM STORM PIPE CONNECTION IN FRONT OF PUBLIX | |||
| DRAINAGE PIPE PLACEMENT | 08/06/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/6/2015 12:00:37 PM STORM IN FRONT OF PUBLIX CONNECTING TO STURCTURE | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 08/04/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 8/4/2015 12:20:48 PM DUMPSTER BEHIND PUBLIX | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 08/03/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 8/3/2015 12:07:35 PM TRASH DUMPSTER REAR OF PUBLIX | |||
| DRAINAGE STRUCTURE PLACEMENT | 07/27/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/27/2015 2:34:54 PM REAR STRUCTURE PLACEMENT | |||
| ASPHALT PRE-PLACEMENT | 07/24/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/24/2015 2:40:14 PM IN PROGRESS | |||
| ASPHALT PRE-PLACEMENT | 07/22/2015 | CANCELLED BY APPLICANT | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ASPHALT PRE-PLACEMENT | 07/21/2015 | CANCELLED BY APPLICANT | CMINI |
| BLD - SITE LIGHTING-CONDUCTORS/CONNECTORS | 07/21/2015 | PARTIALLY APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/21/2015 3:03:57 PM LOOKED AT SITE LTG CONDUIT, NEED TO CALL IN A EARLY POWER | |||
| ASPHALT PRE-PLACEMENT | 07/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 7/20/2015 1:15:25 PM IN PROGRESS | |||
| ROAD BASE/DENSITY | 07/20/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 7/20/2015 1:15:24 PM CHECKED COMPACTION PAPERS | |||
| ASPHALT PRE-PLACEMENT | 07/17/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 7/17/2015 11:04:38 AM IN PROGRESS | |||
| BLD - SITE LIGHTING-CONDUCTORS/CONNECTORS | 07/16/2015 | PARTIALLY APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/16/2015 11:03:30 AM MARKED ON PLAN | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 07/14/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/14/2015 7:18:15 AM BEING INSTALLED | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 07/08/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/8/2015 3:21:46 PM 6" FIRE BACKFLOW SET BEHIND A1 | |||
| ASPHALT PRE-PLACEMENT | 07/08/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/8/2015 3:02:08 PM APPROX 30000 SQ FT IN FRONT OF EYECARE EXPRESS | |||
| ASPHALT PRE-PLACEMENT | 07/06/2015 | PARTIALLY APPROVED | JCOLASANTI |
| Note: Inspection Resulted at 7/6/2015 1:43:15 PM ASPHALT AREA AROUND NEW SALSA RES. REMOVED OLD ASPHALT DUE TO GRADING. INSTALLED 1" ASPHALT OVER BASE. | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 07/06/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/6/2015 3:51:30 PM ALL PARTS HAVE NOT ARRIVED NOT COMPLETE | |||
| LDSC-TREE BARRICADE | 07/06/2015 | APPROVED | WBUTLER |
| U-GRAVITY SEWER INSTALL/TESTING | 07/02/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/2/2015 2:41:45 PM 1 MANHOLE INSTALLED SOUTH OF ISLAND DOCTORS AND SERVICE REROUTED FROM UPS STORE | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 07/01/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 7/1/2015 3:41:45 PM DEVICE ON SITE | |||
| U-WATER SERVICE INSTALLATION | 06/25/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/25/2015 2:35:36 PM CALLED IN IN ERROR FOR 6" WATER MAIN TAP FOR FIRE LINE | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 06/25/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION a 6" tap for the fire system was installed to replace the 4" thet was removed capped and shut off at the main to be abandoned | |||
| U-WATER MAIN DISINFECTION SAMPLING | 06/25/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: samples passed | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/25/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/25/2015 1:26:37 PM TRASH DUMPSTER FOOTER SLAB NEXT TO OLD PUBLIX | |||
| BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS | 06/25/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 6/25/2015 1:26:37 PM AT REAR OF BUILDING | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/24/2015 | APPROVED - AS NOTED | CMINI |
| Note: Inspection Resulted at 6/24/2015 12:08:07 PM TOP OUT ON TRASH LINTEL STEEL | |||
| U - SEWER TIE IN | 06/24/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 6/24/2015 3:46:27 PM ALL SEWER WYE INSTALLATIONS BEHIND THESE UNITS HAVE BEEN CUT IN | |||
| U - SEWER TIE IN | 06/23/2015 | APPROVED | DSPENCER |
| U-GRAVITY SEWER INSTALL/TESTING | 06/23/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/23/2015 4:26:51 PM 3 SEWER WYES CUT IN INSTALLED TO EXISTING SYSTEM BEHIND BUILDINGS A1 A2 | |||
| BLD - SITE LIGHTING-CONDUCTORS/CONNECTORS | 06/23/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 6/23/2015 2:22:24 PM UNDERGROUND BEHIND PUBLIX SITE LIGHTING | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/23/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/23/2015 2:22:24 PM LINTEL STEEL | |||
| DRAINAGE PIPE PLACEMENT | 06/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/19/2015 12:07:29 PM NEXT TO G BUILDING | |||
| DRAINAGE STRUCTURE PLACEMENT | 06/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/19/2015 12:07:30 PM NEXT TO BUILDING G | |||
| BLD - FLATWORK-SIDEWALK/PADS/PATIOS/LANAI/LANDINGS | 06/19/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 6/19/2015 12:07:29 PM FRONT OF BUILDINGS | |||
| U-REUSE MAIN INSTALL/TESTING | 06/16/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 6/16/2015 8:41:29 PM LOCATES WARE MADE AND WORK HAS NOT STARTED | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 06/16/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/16/2015 2:54:15 PM 1050 SET AT NORTH BUILDING ON WEST END TO BE PLUMBED | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/16/2015 12:19:12 PM TRASH DUMPSTER | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/12/2015 | PARTIALLY APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| DRAINAGE PIPE PLACEMENT | 06/12/2015 | PARTIALLY APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/12/2015 1:14:28 PM 50`` OF 36" RCP PIPE AT POND BY SALSA RES. | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/11/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/11/2015 2:10:45 PM FOOTER SLABS | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/09/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| U-GRAVITY SEWER INSTALL/TESTING | 06/09/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/9/2015 11:29:19 AM INSTALLED START MANHOLE IN FRONT OD DENTIST NEXT TO PUBLIX MAINS NOT RUN | |||
| U-WATER SERVICE INSTALLATION | 06/09/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 6/9/2015 11:29:18 AM MORE TO BE DONE | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 06/05/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/5/2015 2:34:58 PM NEED CONTINUOUS REBAR AROUND CORNERS OF SLAP. | |||
| DRAINAGE PIPE PLACEMENT | 06/05/2015 | PARTIALLY APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/5/2015 2:34:58 PM CONTRACTOR USED GREEN PIPE FOR ROOF DRAIN. SHOULD BE WHITE PIPE FOR THIS APPLICATION | |||
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 05/21/2015 | APPROVED | DSPENCER |
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 05/21/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 5/21/2015 3:57:55 PM INTERCEPTOR HAS BEEN INSTALLED AND PARTIALY PLUMMED | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 05/20/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 05/20/2015 | APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 05/14/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/14/2015 2:22:17 PM 3 INTERCEPTORS HAVE BEEN SET WEST END OF PROJECT | |||
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 05/13/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/13/2015 10:46:46 AM OK | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 05/13/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/13/2015 10:46:47 AM 3 INSTALLED SOUTH END OF WEST BUILDING NOT PLUMBED | |||
| DRAINAGE STRUCTURE PLACEMENT | 05/13/2015 | PARTIALLY APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/13/2015 12:08:58 PM MARKED ON PLAN STRUCTURE PLACEMENT | |||
| DRAINAGE PIPE PLACEMENT | 05/07/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/7/2015 2:31:42 PM PARTIAL | |||
| DRAINAGE PIPE PLACEMENT | 05/04/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/4/2015 1:20:58 PM PARTIAL PIPE PLACEMENT | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 05/01/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 5/1/2015 10:34:57 AM PSI TESTING OF NEW 8" MAIN BEHIND BUILDING AND PART OF THE NEW 8" LINES IN FRONT OF NEW PUBLIX BEING TESTED | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 04/29/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 4/29/2015 11:16:44 AM LINTEL INSPECT6ION HIGHLIGHTED ON PLAN | |||
| DRAINAGE STRUCTURE PLACEMENT | 04/21/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/21/2015 3:03:01 PM HIGHLIGHTED ON PLAN, NEED TO CORRECT FALLEN MORTOR | |||
| DRAINAGE PIPE PLACEMENT | 04/21/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/21/2015 3:03:03 PM PIPE PLACEMENT HIGHLIGHTED ON PLAN | |||
| BLD - UNDERGROUND SITE LIGHTING CONDUITS | 04/16/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/16/2015 11:32:57 AM PARTIAL HIGHLIGHTED ON PLAN | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 04/13/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: THIS IS A REINSPECTION | |||
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 04/13/2015 | CANCELLED BY APPLICANT | DSPENCER |
| U-GREASE INTERCEPTOR PRE-INSTALLATION | 04/08/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 4/8/2015 12:47:00 PM NOT ALL HAVE BEEN DELIVERED | |||
| U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR | 04/08/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 4/8/2015 7:33:14 AM BUILDING A-1, A-2, DEMO ISLAND WALK - STAGE 1 & 2 (SHEET 42 - 43 OF APPROVED CIVIL PLANS) WORK UNDER WAY | |||
| BLD - SITE STRUCTURE - TRASH DUMPSTER | 04/08/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 4/8/2015 12:00:51 PM FOOTER ON TRASH DUMPSTER HIGHLIGHTED ON PLAN | |||
| BLD - SITE LIGHTING-POLE SET/FIXTURE | 04/01/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/1/2015 2:59:56 PM FIXTURES LGHTS | |||
| DRAINAGE PIPE PLACEMENT | 04/01/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/1/2015 2:59:56 PM PIPEPLACEMENT HIGHLIGHTED ON PLAN | |||
| DRAINAGE STRUCTURE PLACEMENT | 04/01/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 4/1/2015 2:59:55 PM STRUCTURES IN PLACE HIGHLIGHTED ON PLACE | |||
| DRAINAGE PIPE PLACEMENT | 03/25/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION..pipe highkighted on plan | |||
| DRAINAGE STRUCTURE PLACEMENT | 03/25/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION..structure 42-43 | |||
| BLD - SITE LIGHTING-POLE SET/FIXTURE | 03/25/2015 | PARTIALLY APPROVED | CMINI |
| Note: pole sets and underground conduit, highlighted on plan | |||
| DRAINAGE STRUCTURE PLACEMENT | 03/20/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/20/2015 10:53:10 AM STRUCTURE D3 | |||
| DRAINAGE STRUCTURE PLACEMENT | 03/11/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/11/2015 1:51:06 PM ROOF DRAIN PIPE TO STRUCTURE 32 | |||
| DRAINAGE PIPE PLACEMENT | 03/11/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/11/2015 2:21:06 PM ROOF DRAIN PIPE TO STRUCTURE 32 | |||
| DRAINAGE PIPE PLACEMENT | 03/10/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/10/2015 10:42:58 AM STRUCTURE 31A AND 32 AND PIPING TO THEM | |||
| DRAINAGE PIPE PLACEMENT | 03/03/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/3/2015 10:29:47 AM PIPE PLACEMENT BETWEEN STRUCTURES 10 AND 11 | |||
| DRAINAGE STRUCTURE PLACEMENT | 03/03/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 3/3/2015 10:29:48 AM STRUCTURES 10 AND 11 | |||
| DRAINAGE PIPE PLACEMENT | 02/27/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/27/2015 1:24:05 PM IN PROGREES OF PIPE AND STRUCTURE, WILL CHECK COMPLETE ON NEXT INSPECTION OF THAT SECTION | |||
| DRAINAGE PIPE PLACEMENT | 02/26/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/26/2015 11:50:38 AM PIPES MUDDED INTO STRUCTURES THAT WERE SET THE OTHER DAY | |||
| DRAINAGE PIPE PLACEMENT | 02/24/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/24/2015 1:17:13 PM PARTIAL CIRCLED ON PLAN | |||
| BLD - UNDERGROUND SITE LIGHTING CONDUITS | 02/24/2015 | PARTIALLY APPROVED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/24/2015 1:17:13 PM PARTIAL CIRCLED ON PLAN | |||
| DRAINAGE PIPE PLACEMENT | 02/13/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/13/2015 11:52:12 AM PIPE PLACEMENT BETWEEN STRUCTURES 13,14,15 | |||
| DRAINAGE STRUCTURE PLACEMENT | 02/13/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 2/13/2015 11:52:12 AM STRUCTURES 13,14,15 | |||
| U-GRAVITY SEWER INSTALL/TESTING | 01/30/2015 | PARTIALLY APPROVED | DSPENCER |
| Note: Inspection Resulted at 1/30/2015 12:33:57 PM AREA WILL POINTED AND MATERIALS SET FOR MONDAY INSTALLATION STARTING | |||
| BLD - UNDERGROUND SITE LIGHTING CONDUITS | 01/07/2015 | PARTIALLY APPROVED | CMINI |
| Note: Inspection Resulted at 1/7/2015 3:16:07 PM PARTIAL UNDERGROUND FROM TRANSFORMER HIGHLIGHTED ON PLANS | |||
| LDSC-TREE BARRICADE | 11/25/2014 | APPROVED | CJMINI |
Review History
| Department | Status | Date In | Date Out |
| DSD | COMPLETE | 09/28/2015 | 09/28/2015 |
| PLLA | COMPLETE | 09/28/2015 | 09/28/2015 |
| Note: Approved as noted below: Need to resubmit sheet L3.04 to show the missing drip zone valve near the Old Kings Road entrance and the wire splice box in VUA island 24 per the marked-up plan. Also need to submit a revised sheets L1.05 and L3.05 with the note stating, "As-built only for phase 1 area". | |||
| UD1 | COMPLETE | 09/22/2015 | 09/24/2015 |
| DSD | HOLD | 09/22/2015 | 09/23/2015 |
| Note: 1. Repeat previous comment: Remove the unconstructed truck well and loading dock depicted on the northwest corner of the existing “B” building that appears on the Water As-Built sheet and the Paving, Grading, Drainage sheets. UPDATED: Additionally, please remove the depiction of this truck well and loading dock from all As-built sheets. | |||
| PLLA | HOLD | 09/22/2015 | 09/23/2015 |
| Note: Landscape and irrigation as-builts not correct. Also only need to submit the sheets for phase 1 as-built and associated detail sheets and not the entire set that is not in phase 1. Marked up plans were e-mailed to the general contractor, landscape contractor and project landscape architect | |||
| BLD | COMPLETE | 09/14/2015 | 09/16/2015 |
| DSD | HOLD | 09/14/2015 | 09/18/2015 |
| Note: Remove the truck well and loading dock depicted on the northwest corner of the existing “B” building that appears on the Water As-Built sheet and the Paving, Grading, Drainage sheets. The structures are not yet approved, nor are they constructed. | |||
| ENGIN1 | COMPLETE | 09/14/2015 | 09/16/2015 |
| PLLA | HOLD | 09/14/2015 | 09/18/2015 |
| Note: No landscape or irrigation as-builts submitted. | |||
| SW1 | COMPLETE | 09/14/2015 | 09/16/2015 |
| UD1 | HOLD | 09/14/2015 | 09/17/2015 |
| Note: Provide updated as-built | |||
| ZON | COMPLETE | 09/14/2015 | 09/14/2015 |
| Note: No Zoning Review needed. | |||
| FI1 | COMPLETE | 08/27/2015 | 08/31/2015 |
| ELEC | COMPLETE | 06/30/2015 | 07/02/2015 |
| SW1 | COMPLETE | 06/09/2015 | 06/09/2015 |
| DSD | COMPLETE | 06/04/2015 | 06/08/2015 |
| Note: Retaining wall only as noted on plan. | |||
| ZON | COMPLETE | 06/04/2015 | 06/09/2015 |
| Note: Retaining wall only as noted on plan. | |||
| PLLA | COMPLETE | 06/04/2015 | 06/05/2015 |
| BLD | COMPLETE | 06/04/2015 | 06/08/2015 |
| BLD | HOLD | 05/20/2015 | 05/26/2015 |
| Note: Identify height of retaining wall. If 30" or higher within a three foot horizontal distance a guard rail shall be provided. | |||
| DSD | HOLD | 05/20/2015 | 05/21/2015 |
| Note: 1. Please provide color elevations of the retaining wall system for review. | |||
| ENGIN1 | COMPLETE | 05/20/2015 | 05/20/2015 |
| PLLA | HOLD | 05/20/2015 | 05/21/2015 |
| Note: 1. As discussed in the field, please revise the plan to show the drainage pipe out of the tree well and tying into the inlet that lies to the southwest of the tree island. 2. As discussed in the field, please revise the plan to clearly show that the parking space that lies between the terminal island and the proposed modified tree island is being eliminated and incorporated into the landscaped area. Currently the plan makes it appear to remain in place. 3. Informational: the parking space being removed could be specified as an area to be decked for cart storage if needed; however, if taking this option, please provide details on the decking to be supplied. | |||
| SW1 | COMPLETE | 05/20/2015 | 05/20/2015 |
| UD1 | COMPLETE | 05/20/2015 | 05/20/2015 |
| ZON | HOLD | 05/20/2015 | 05/21/2015 |
| Note: 1. Please revise per DSD (Planning) comment. | |||
| ELEC | COMPLETE | 04/21/2015 | 04/22/2015 |
| UD1 | COMPLETE | 11/03/2014 | 11/03/2014 |
| Note: Released By: CJOHNSON | |||
| BLD | COMPLETE | 10/30/2014 | 11/03/2014 |
| DSD | COMPLETE | 10/30/2014 | 11/04/2014 |
| ENGIN1 | COMPLETE | 10/30/2014 | 10/31/2014 |
| SW1 | COMPLETE | 10/30/2014 | 10/31/2014 |
| UD1 | HOLD | 10/30/2014 | 10/30/2014 |
| Note: Provide FDEP permits | |||
| ZON | COMPLETE | 10/30/2014 | 11/04/2014 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/29/2015 |
| REINSPECTION FEE | ¤40.00 | 09/29/2015 |
| REVISION | ¤40.00 | 09/29/2015 |
| REVISION | ¤40.00 | 09/29/2015 |
| REVISION | ¤40.00 | 09/29/2015 |
| SITE PLAN 20 | ¤20.00 | 11/05/2014 |
| INSPECTION 40 | ¤1,880.00 | 11/05/2014 |
| PERMIT FEE | ¤125.00 | 11/05/2014 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤2,225.00 |