I want to search for...
Permit #2014120029
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7002-00060-0310 |
| Block: 00060 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-225-3304 |
| Location Address: 30 FERNHAM LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 01/16/2015 |
| NOC: RECORDED |
| Applicant name: FRANK ROBERT SORRENTINO |
| Owner: CAMPBELL GORDON JR & DENA L WEST H&W |
|
Address 30 FERNHAM LANE PALM COAST, FL 32137 |
| Lot: 0310 |
| Contracted Stated Job Value: ¤35,000.00 |
| Job Description: ENCLOSING EXISTING POOL W/SGD ROOF & TRELLIS |
| Type: CN |
Contractor
CLEAR CHOICE WINDOWS OF NORTH FLORIDA
| Status | Location Address | State License Number | Phone |
| CANCEL |
212 BEECHWOOD LANE PALM COAST, FL 32137 |
CBC1258275 (Exp: 08/31/2016) | 386-225-3304 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/19/2015 | FINAL APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 05/21/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 5/21/2015 11:04:11 AM NEED TO HAVE REVISED ELECTRICAL PLANS ON SITE AT TIME OF INSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/13/2015 | APPROVED | FREODICA |
| LATH/BRICK/ WATER BARRIER | 04/09/2015 | APPROVED | CMINI |
| INSULATION | 03/13/2015 | APPROVED | JHINDMAN |
| ALL ROUGH | 03/10/2015 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 3/10/2015 10:59:11 AM NEED REVISION TO ELECTRICAL PLAN TO SHOW EXHAUST FAN BY EXTERIOR DOOR, SHOW RECEPTICAL IN CEILING, AND REMOVAL OF LIGHT RIGHT CORNER AND RELOCATION OF SWITCHES. | |||
| FOUND SURVEY APPROVED (OFFICE) | 03/06/2015 | APPROVED | FREODICA |
| FOOTER | 03/04/2015 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/26/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/19/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 2/19/2015 11:20:04 AM NEED REVISION ON HEADER BUILT IN FIELD, NEED REVISION FOR STRAPS USED IN FIELD INSTEAD OF LGT3 ON PLAN. EXPOSE STRAPS AT END POSTS. NEED TO CALL IN SHEETING INSPECTION FOR TRELUS AT SIDE OF HOUSE. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/17/2015 | 06/18/2015 |
| ELEC | HOLD | 05/29/2015 | 06/05/2015 |
| Note: Clarify if floodlights are included as plan. Does not show any wiring FBC 2010 107.2.1 | |||
| SW1 | COMPLETE | 05/13/2015 | 05/13/2015 |
| Note: Released By: FREODICA final survey | |||
| SW1 | COMPLETE | 03/04/2015 | 03/06/2015 |
| Note: Released By: FREODICA foundation survey | |||
| BLD | COMPLETE | 02/24/2015 | 02/25/2015 |
| ELEC | COMPLETE | 01/14/2015 | 01/14/2015 |
| ELEC | HOLD | 01/13/2015 | 01/13/2015 |
| Note: 1. lighting fixtures around the pool must be 5 feet from the waters edge. 2gfci must be 6 feet from the waters edge 2008 NEC 680 | |||
| ZON | COMPLETE | 01/08/2015 | 01/09/2015 |
| ELEC | HOLD | 01/08/2015 | 01/09/2015 |
| Note: 1.Provide exterior lighting at doors. 2008 NEC 210.70. 2. Ceiling fan boxes cannot be less than 5 feet from the waters edge. 2008 NEC 680.22 C 1. 3. GFCI receptacle cannot be within 6 feet of the waters edge. 2008 NEC 680.22. | |||
| BLD | COMPLETE | 01/08/2015 | 01/12/2015 |
| ZON | HOLD | 12/29/2014 | 12/30/2014 |
| Note: As per meeting with zoning staff, rear landscaping must be shown to soften rear of proposed structure (pictures of existing landscaping and/or drawing of proposed new landscaping), plans must note that rolled roofing will match existing roof and trellis must meet setbacks of zoning district (7.5' side setback). Also please note dimensions of trellis on site plan. | |||
| SW1 | COMPLETE | 12/29/2014 | 01/05/2015 |
| BLD | HOLD | 12/29/2014 | 01/06/2015 |
| Note: Provide a plan for the rooms that are adjacent to the pool. Are any bedrooms connected and do they have the proper egress from them? 2010 FBC 107.2.1. 2nd request. | |||
| ELEC | HOLD | 12/29/2014 | 01/05/2015 |
| Note: 1. Provide a plan of the proposed electrical work. 2.Provide exterior lighting at doors. 2008 NEC 210.70. 3. Are the doors and windows from the house going to remain. If not provide electric receptacles per code. | |||
| BLD | HOLD | 12/02/2014 | 12/05/2014 |
| Note: 1. Provide information Are the doors and window from the house going to be removed? 2. Provide pool alarms for all of the new doors and windows. 2010 FBC R 4101.17. 3. Provide a roof truss engineering layout from the truss manufacturer. 2010 FBC 107.2.1. 4. Provide a typical wall section that includes the wall framing between the posts and the wall and finishes. 2010 FBC 107.2.1. 5. provide a plan for the rooms that are adjacent to the pool. Are any bedrooms connected and do they have the proper egress from them? | |||
| ELEC | HOLD | 12/02/2014 | 12/05/2014 |
| Note: 1. Provide a plan of the proposed electrical work. 2.Provide exterior lighting at doors. 2008 NEC 210.70. 3. Are the doors and windows from the house going to remain. If not provide electric receptacles per code. 4. Provide electrical contractor. | |||
| SW1 | HOLD | 12/02/2014 | 12/02/2014 |
| Note: 1. Provide a siteplan that shows the proposed drainage. | |||
| ZON | HOLD | 12/02/2014 | 12/02/2014 |
| Note: 1. Site plan must show location, dimensions and setbacks of trellis. 2. Per LDC 13.03.02 Roofs. Roofs that are visible from the public right-of-way (of which the saltwater canal is included) shall be of shed, hip, gambrel, mansard, or gable styles. Also, flat roofs are not allowed when visible from the public right-of-way. A minimum 5:12 pitch is required. 3. As per LDC 13.02.05 Accessory structures. The roof, exterior walls and exterior colors of accessory structures, shall be compatible with the design of the principal structure. Therefore, the break metal exterior is not allowed. The exterior walls must match the house. T. Childs 986-2473 | |||
| ZON | HOLD | 12/02/2014 | |
| Note: 1. Site plan must show location, dimensions and setbacks of trellis. 2. Per LDC 13.03.02 Roofs. Roofs that are visible from the public right-of-way (of which the saltwater canal is included) shall be of shed, hip, gambrel, mansard, or gable styles. Also, flat roofs are not allowed when visible from the public right-of-way. A minimum 5:12 pitch is required. 3. As per LDC 13.02.05 Accessory structures. The roof, exterior walls and exterior colors of accessory structures, shall be compatible with the design of the principal structure. Therefore, the break metal exterior is not allowed. The exterior walls must match the house. T. Childs 986-2473 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 06/18/2015 |
| REVISION | ¤40.00 | 06/18/2015 |
| REVISION | ¤40.00 | 05/20/2015 |
| REINSPECTION FEE | ¤40.00 | 05/20/2015 |
| SITE PLAN 20 | ¤20.00 | 01/16/2015 |
| SURCHARGE FS 533.721 | ¤2.72 | 01/16/2015 |
| SURCHARGE - FS 468.631 | ¤2.72 | 01/16/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/16/2015 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 01/16/2015 |
| ADMIN FEE | ¤20.00 | 01/16/2015 |
| ELECTRIC FEE | ¤81.00 | 01/16/2015 |
| PLAN CHECK FEE | ¤40.00 | 01/16/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤446.44 |