I want to search for...

Permit #2014120146

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00200-0090
CONDITIONED SPACE: 2750 sqft
CONDITIONED SPACE: 380 sqft
GARAGE: 505 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
Total Square Footage: 3735 sqft
Block: 00200
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: (386) 445-2222
Location Address: 102 WHITTINGTON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/22/2014
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: HALL JAMES L & GLADYS H&W

Address

11 ARDMORE ROAD

WEST ORANGE, NJ 07025

Lot: 0090
Contracted Stated Job Value: ¤310,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
DANIEL P HUCKS
Status Location Address State License Number Phone Fax
CANCEL

400 N. U.S. 1

Ormond Beach, FL 32174

CAC029376 (Exp: 08/31/2024) 386-672-8494 386-673-7856
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
STEPHEN M RENDE
Status Location Address State License Number Phone
CANCEL

22 ALAMANDA DRIVE

ORMOND, FL 32176

CCC058058 (Exp: 08/31/2020) 386-439-7156

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 09/01/2015 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 08/28/2015 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROW FINAL 08/28/2015 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION Road damage being repaired by City.
BLD - BUILDING FINAL 08/21/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 8/21/2015 10:45:14 AM GENERATOR NEEDS TO BE ON SEPERATE PERMIT FOR GENERATOR AND GAS. START UP NEEDS TO BE PERFORMED AND FINALED BEFORE HOUSE FINAL.
ROW FINAL 08/21/2015 Disapproved -FEE REQUIRED CTROHA
Note: ERROSION ISSUE IN ROW OF DITCH AT REAR OF PROPERTY IT NEEDS TO BE UNDER CONTROL AND SODDED WITH BAHIA SOD (NO SEED AND HAY) PAY CITY COST OF $252.00 FOR ROAD REPAIR OR REPAIR 19' OF ROAD DAMAGE
FINAL SURVEY (OFFICE USE ONLY) 08/20/2015 Disapproved - NO FEE DREWIS
Note: Please provide utility easement measurement for driveway. Culvert invert on east side of driveway is higher than swale diagram allows. -DC. Rewis 986-4736
FINAL SURVEY (OFFICE USE ONLY) 08/20/2015 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL APRON (AFTER POUR/DRIVEWAY) 08/04/2015 APPROVED RGROSS
U - SEWER TIE IN 07/30/2015 APPROVED MBACON
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 07/30/2015 APPROVED JCOLASANTI
GRAVITY SEWER TEST 07/29/2015 CANCELLED BY APPLICANT JCOLASANTI
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 07/29/2015 CANCELLED BY APPLICANT MBACON
Note: THIS IS A REINSPECTION
U - SEWER TIE IN 07/24/2015 Disapproved -FEE REQUIRED MBACON
Note: Inspection Resulted at 7/24/2015 2:29:59 PM SEWER TIE IN IS NOT COMPLETED. PLEASE CALL TO SCHEDULE A TIME SO INSPECTOR CAN WITNESS.
PRE-APRON (PRE-POUR/DRIVEWAY) 07/24/2015 APPROVED - AS NOTED RGROSS
Note: Pipe ends are not the same distance from the road edge. Adjusted for better stormwater flow.
GRAVITY SEWER TEST 07/24/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 7/24/2015 2:58:15 PM PIPE IS COVERED CANNOT SEE CONNECTIONS. CAP ON TIGHT NEED TO MAKE SURE WATER TIGHT.
ELECTRIC - EARLY POWER 07/14/2015 APPROVED JCOLASANTI
Note: Inspection Resulted at 7/14/2015 2:33:26 PM SPOKE TO DALE AT FPL TO RELEASE POWER
LATH/BRICK/ WATER BARRIER 04/28/2015 APPROVED JCOLASANTI
ELECTRIC-TUG 04/24/2015 APPROVED JCOLASANTI
Note: Inspection Resulted at 4/24/2015 2:28:23 PM SPOKE WITH SUSAN TO RELEASE POWER
INSULATION 04/23/2015 APPROVED JCOLASANTI
ALL ROUGH 04/02/2015 APPROVED - AS NOTED JCOLASANTI
Note: Inspection Resulted at 4/2/2015 3:15:52 PM PHASE OUT AC HOT CONDUCTOR FURTHER UP. WILL CHECK AT INSULATION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/01/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/31/2015 CANCELLED BY APPLICANT AIRS WEB
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/23/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 3/23/2015 3:09:50 PM NEED DETAILS FOR BEARING WALLS, BEARING WALL OPENINGS. NEED TO TIGHTEN BOLTS BEARING WALL AT GARAGE.
TIE BEAM / LINTEL 01/30/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 01/28/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 1/28/2015 3:02:16 PM NEED DETAIL FOR CONTINUOUS LOAD PATH AT LENTEL (BOTH ENDS) AT FRONT ENTRANCE. NEEDS TO BE TIED DOWN TO FOOTER STEEL
MONOLITHIC SLAB 01/22/2015 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 01/22/2015 APPROVED FREODICA
MONOLITHIC SLAB 01/21/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 1/21/2015 2:22:21 PM RELIEVING ARCH IN FOOTING P2603.5
PLUMBING 1ST ROUGH UNDERGROUND 01/16/2015 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/19/2015 08/20/2015
Note: Released By: DREWIS
SW1 HOLD 08/18/2015 08/19/2015
Note: Held By: DREWIS Please provide measurement for utility easement on driveway. Culvert invert on east side of driveway is higher than swale diagram allows. -DC. Rewis 986-4736
BLD COMPLETE 07/20/2015 07/21/2015
Note: Non- structural. Not applicable.
SW1 COMPLETE 07/20/2015 07/20/2015
UD1 COMPLETE 07/20/2015 07/21/2015
Note: See Notes
ZON COMPLETE 07/20/2015 07/22/2015
BLD COMPLETE 03/26/2015 03/27/2015
BLD COMPLETE 03/17/2015 03/17/2015
SW1 COMPLETE 01/21/2015 01/22/2015
Note: Released By: FREODICA foundation s
MECH COMPLETE 12/22/2014 12/22/2014
UD1 COMPLETE 12/15/2014 12/19/2014
ELEC COMPLETE 12/15/2014 12/15/2014
BLD COMPLETE 12/15/2014 12/16/2014
MECH HOLD 12/15/2014 12/15/2014
Note: Previous comment on energy calculation and euipment sizing calculation shall be provided per 2010 FBCEC 403.6.
BLD HOLD 12/04/2014 12/08/2014
Note: 1. Provide an emergency egress opening from the master suite to the outside per 2010 FBC R 310.1.1. 2. Provide all litel sizes at florida room and dining room. 2010 FBC 107.2.1. 3. Provide a header size for the triple slider span. 2010 FBC 2308.9.5. J. Hindman 986-3784.
ELEC HOLD 12/04/2014 12/08/2014
Note: 1. Provide an exterior light outside of rear door. 2008 NEC 210.70. J. Hindman 986-3784.
ENGIN1 COMPLETE 12/04/2014 12/08/2014
MECH HOLD 12/04/2014 12/09/2014
Note: Provide energy calculation, equipment sizing calculation, manufacturer and model number of outdoor and indoor units per 2010 FBCEC 403.6.
PLUM COMPLETE 12/04/2014 12/08/2014
SW1 COMPLETE 12/04/2014 12/08/2014
UD1 HOLD 12/04/2014 12/04/2014
Note: PEP Panel is not shown in the electrical plan. Submit a new electrical plan showing PEP Panel on the building on the same side of the building as indicated in the Utility marked site plan. See comment in general notes Danny Spencer 386-386-2640
URB COMPLETE 12/04/2014 12/05/2014
ZON COMPLETE 12/04/2014 12/05/2014

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ENGINEERING ROAD DAMAGE ¤252.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REINSPECTION FEE ¤40.00 08/25/2015
REVISION ¤40.00 08/25/2015
REVISION ¤40.00 08/25/2015
SITE PLAN 20 ¤20.00 12/22/2014
SURCHARGE FS 533.721 ¤26.37 12/22/2014
SURCHARGE - FS 468.631 ¤26.37 12/22/2014
STORM WATER PERMIT FEES ¤80.00 12/22/2014
3% TRANS IMPACT FEE CREDIT (¤90.51) 12/22/2014
ADMIN FEE ¤20.00 12/22/2014
ELECTRIC FEE ¤282.60 12/22/2014
NEW RESIDENTIAL INSPECTIONS ¤742.00 12/22/2014
3% FIRE IMPACT FEE CREDIT (¤6.33) 12/22/2014
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 12/22/2014
IMPACT FEE PARKS ¤849.24 12/22/2014
IMPACT FEE SCHOOL ¤3,600.00 12/22/2014
IMPACT FEE TRANSPORTATION ¤3,017.05 12/22/2014
MECHANICAL FEE ¤282.60 12/22/2014
3% PARKS IMPACT FEE CREDIT (¤25.48) 12/22/2014
PLAN CHECK FEE ¤148.40 12/22/2014
PLUMBING FEE ¤282.60 12/22/2014
Fees Total Due: ¤0.00 Total Paid: ¤10,078.02