I want to search for...

Permit #2015020075

Permit Details

Status: COED

Parcel Id: 07-11-31-7013-00160-0410
CONDITIONED SPACE: 1816 sqft
GARAGE: 575 sqft
OPENED PORCH (WITH ROOF) : 149 sqft
OPENED PORCH (WITH ROOF) : 28 sqft
Total Square Footage: 2568 sqft
Block: 00160
Subdivision: 2192 - SECTION 13-BELLE TERRE
Job Phone: (904)296-1490
Location Address: 64 BRUCE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/04/2015
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES INC

Address

9700 PHILIPS HWY

JACKSONVILLE, FL 32256

Address

SUITE 102

JACKSONVILLE, FL 32256

Lot: 0410
Contracted Stated Job Value: ¤90,308.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone Fax
CANCEL

9474 OLD PLANK RD

JACKSONVILLE , FL 32220

CCC1328530 (Exp: 08/31/2016) 904-435-7663 904-404-8406

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 10/02/2015 FINAL APPROVED MBACON
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 10/01/2015 Disapproved - NO FEE MBACON
Note: Inspection Resulted at 10/1/2015 8:33:30 AM PLEASE LOWER 4 INCH CLEANOUT TO GRADE AND ALSO USE ONLY FLUSHMOUNT CAP. WE DO NOT ALLOW RAISED NUT CAPS.
BLD - BUILDING FINAL 09/30/2015 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 09/29/2015 Disapproved - NO FEE JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 9/29/2015 11:03:08 AM CITY APPROVED FINAL SURVEY MUST BE ON SITE AT TIME OF INSPECTION. NO CITY STAMP ON SURVEY ON SITE AT TIME OF INSPECTION,
BLD - BUILDING FINAL 09/28/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 9/28/2015 11:26:19 AM VACUM BREAKER HOSE BIB RIGHT SIDE 2902.3.4......NEED FINAL SURVEY ON SITE AT TIME OF INSPECTION.
FINAL APRON (AFTER POUR/DRIVEWAY) 09/28/2015 APPROVED RGROSS
Note: THIS IS A REINSPECTION
ROW FINAL 09/28/2015 APPROVED - AS NOTED RGROSS
Note: Road edge at driveway cut out, but not yet hot patched. Must be finished.
FINAL SURVEY (OFFICE USE ONLY) 09/24/2015 APPROVED DREWIS
FINAL APRON (AFTER POUR/DRIVEWAY) 09/08/2015 Disapproved -FEE REQUIRED RGROSS
Note: No explansion saw cut over culvert. No sod around new pour edges to prevent washout. No hot patch at road edge and driveway apron.
PRE-APRON (PRE-POUR/DRIVEWAY) 09/01/2015 APPROVED RGROSS
Note: READY TO POUR
ELECTRIC - EARLY POWER 08/17/2015 APPROVED JCOLASANTI
Note: Inspection Resulted at 8/17/2015 3:37:10 PM SPOKE TO DALE AT FPL TO RELEASE POWER
U - SEWER TIE IN 08/07/2015 APPROVED DSPENCER
LATH/BRICK/ WATER BARRIER 07/29/2015 APPROVED JCOLASANTI
INSULATION 07/16/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 07/15/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 7/15/2015 2:20:35 PM MISSING FIRESTOPPING AT ELECTRIC PANEL FRAMING BY ATTIC
ALL ROUGH 07/09/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ALL ROUGH 07/07/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 7/7/2015 2:10:45 PM NEED TO PHASE OUT HOT CONDUCTORS IN BOXES.210.5(C).......NEED GREEN SCREW GROUND AT BOX......
ALL ROUGH 07/06/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 7/6/2015 11:13:15 AM NEED TO PHASE OUT HOT CONDUCTORS IN BOXES.210.5(C).......NEED GREEN SCREW GROUND AT BOX......TUB GUEST BATH PLUMBING AT SLAB NEEDS FILLED....NAIL PLATE GUEST BATH (ORANGE PAINT). WIRE AGAINST GUSSET AT HALL WAY. (;ORANGE PAINT).. GUEST BEDROOM BY GARAGE RECEPTICAL WALL SPACING ORANGE PAINT. REVISE PLAN TO SHOW ADDED RECEPTICALS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/01/2015 APPROVED JCOLASANTI
TIE BEAM / LINTEL 06/01/2015 APPROVED JCOLASANTI
MONOLITHIC SLAB 05/19/2015 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 05/15/2015 APPROVED JCOLASANTI
GRAVITY SEWER TEST 05/15/2015 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 05/14/2015 APPROVED FREODICA
STEM WALL FOUNDATION 05/04/2015 CANCELLED BY APPLICANT AIRS WEB
FOOTER 05/01/2015 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 COMPLETE 09/24/2015 09/24/2015
Note: Released By: DREWIS final s
SW1 COMPLETE 05/14/2015 05/14/2015
Note: Released By: FREODICA foundation s
ELEC COMPLETE 04/23/2015 04/23/2015
MECH COMPLETE 04/23/2015 04/23/2015
BLD COMPLETE 03/31/2015 04/02/2015
ELEC HOLD 03/31/2015 03/31/2015
Note: 1. Provide an electrical receptacle at wall between bedroom 3 door and closet. 2008 NEC 210.52
MECH HOLD 03/31/2015 04/07/2015
Note: 1. Provide revised energy calculations 2010 FBC 107.2.1.
ZON COMPLETE 03/31/2015 04/01/2015
PLUM COMPLETE 02/19/2015 02/19/2015
PLUM HOLD 02/17/2015 02/17/2015
Note: Previous comment shall be addressed correctly to process the permit application. Submitted sanitary riser diagram does not match with floor plan. The master bathroom on floor plan does not show a tub but riser diagram does show. Submit correction for per 2010 FBC 107.2.1.
ELEC COMPLETE 02/09/2015 02/09/2015
PLUM HOLD 02/09/2015 02/09/2015
Note: Submitted sanitary riser diagram does not match with floor plan. The master bathroom on floor plan does not show a tub but riser diagram does show. Submit correction for per 2010 FBC 107.2.1.
ZON COMPLETE 02/09/2015 02/10/2015
BLD COMPLETE 02/03/2015 02/03/2015
ELEC HOLD 02/03/2015 02/03/2015
Note: 1. Provide an electrical receptacle at wall between bedroom 3 door and closet. 2008 NEC 210.52.
ENGIN1 COMPLETE 02/03/2015 02/04/2015
Note: Swale plan to be issued at a later date.
MECH COMPLETE 02/03/2015 02/03/2015
PLUM HOLD 02/03/2015 02/03/2015
Note: Provide sanitary riser diagram with signature and license number of plumbing contractor per 2010 FBC 107.2.1.
SW1 COMPLETE 02/03/2015 02/03/2015
UD1 COMPLETE 02/03/2015 02/03/2015
Note: See comment in general notes Danny Spencer 386-386-2640
URB COMPLETE 02/03/2015 02/04/2015
ZON HOLD 02/03/2015 02/04/2015
Note: Per Land Development Code, maximum garage depth is 30'.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 10/02/2015
REVISION ¤40.00 10/02/2015
REVISION ¤40.00 10/02/2015
REVISION ¤40.00 10/02/2015
REINSPECTION FEE ¤40.00 10/02/2015
REINSPECTION FEE ¤40.00 10/02/2015
REINSPECTION FEE ¤40.00 10/02/2015
REINSPECTION FEE ¤40.00 10/02/2015
REINSPECTION FEE ¤40.00 10/02/2015
NEW RESIDENTIAL INSPECTIONS ¤464.00 03/04/2015
SITE PLAN 20 ¤20.00 03/04/2015
SURCHARGE FS 533.721 ¤17.62 03/04/2015
SURCHARGE - FS 468.631 ¤17.62 03/04/2015
STORM WATER PERMIT FEES ¤80.00 03/04/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 03/04/2015
ADMIN FEE ¤20.00 03/04/2015
ELECTRIC FEE ¤199.20 03/04/2015
3% FIRE IMPACT FEE CREDIT (¤6.33) 03/04/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 03/04/2015
IMPACT FEE PARKS ¤849.24 03/04/2015
IMPACT FEE SCHOOL ¤3,600.00 03/04/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 03/04/2015
MECHANICAL FEE ¤199.20 03/04/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 03/04/2015
PLAN CHECK FEE ¤92.80 03/04/2015
PLUMBING FEE ¤199.20 03/04/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,256.91