I want to search for...
Permit #2015030116
Permit Details
Status: COED
| Parcel Id: 33-11-31-3060-00030-0180 |
| CONDITIONED SPACE: 2146 sqft |
| GARAGE: 503 sqft |
| GARAGE: 62 sqft |
| OPENED PORCH (WITH ROOF) : 370 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| Total Square Footage: 3169 sqft |
| Block: 00030 |
| Subdivision: 2106 - HIDDEN LAKES, PHASE 1 |
| Job Phone: 386-445-9055 |
| Location Address: 186 ARENA LAKE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/22/2015 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: ESTEVAM, FERNANDO S & MARIA L |
|
Address 64 HAMILTON AVE SOUTHINGTON, CT 06489 |
| Lot: 0180 |
| Contracted Stated Job Value: ¤236,060.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SUN STATE CUSTOM BUILDERS, LLC
| Status | Location Address | State License Number |
| CANCEL |
946 SHADICH DRIVE ORANGE CITY, FL |
CGC1519145 (Exp: 08/31/2022) |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
SANTOS L HERNANDEZ
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
946 SHADDICK DRIVE ORANGE CITY, FL 32763 |
CCC1328011 (Exp: 08/31/2026) | 386-218-4942 | 386-218-4937 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 02/17/2017 | FINAL APPROVED | JNICHOLS |
| BLD - BUILDING FINAL | 02/16/2017 | FINAL APPROVED | CMINI |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 02/16/2017 | APPROVED | GLALIMA |
| ROW FINAL | 02/16/2017 | APPROVED | GLALIMA |
| FINAL SURVEY (OFFICE USE ONLY) | 02/15/2017 | APPROVED | FREODICA |
| ELECTRIC - EARLY POWER | 02/03/2017 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION, called fpl to release power spoke to Dell | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 01/23/2017 | APPROVED | GLALIMA |
| U - SEWER TIE IN | 01/19/2017 | APPROVED | JNICHOLS |
| GRAVITY SEWER TEST | 01/19/2017 | APPROVED | CMINI |
| SEWER SERVICE | 01/19/2017 | CANCELLED BY APPLICANT | AIRS WEB |
| ELECTRIC-TUG | 11/22/2016 | APPROVED - AS NOTED | RMARTIN |
| Note: SPOKE TO SUSAN FPL RELEASED TUG | |||
| ELECTRIC - EARLY POWER | 11/21/2016 | Disapproved - NO FEE | RMARTIN |
| Note: NEED TO CALL IN TUG INSPECTION, WRONG INSPECTION WAS CALLED IN | |||
| INSULATION | 10/12/2016 | APPROVED | CMINI |
| LATH/BRICK/ WATER BARRIER | 09/13/2016 | APPROVED | CMINI |
| ALL ROUGH | 09/13/2016 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/13/2016 | APPROVED | CMINI |
| TIE BEAM / LINTEL | 02/19/2016 | APPROVED - AS NOTED | DROCKWELL |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/19/2016 1:38:58 PM LOUIS, NEED REVISION FOR LEFT SIDE ELEVATION CHANGE.PLEASE HAVE BY ALL-ROUGH INSPECTION | |||
| TIE BEAM / LINTEL | 02/02/2016 | CANCELLED BY APPLICANT | DROCKWELL |
| FOUND SURVEY APPROVED (OFFICE) | 10/08/2015 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 06/11/2015 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 6/11/2015 1:10:47 PM NEED A RELIEVING ARCH OVER CLUSTER OF PIPES THRU FOOTER BACK WALL | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/26/2015 | APPROVED | DROCKWELL |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/15/2017 | 02/15/2017 |
| Note: Released By: FREODICA final survey | |||
| SW1 | COMPLETE | 02/08/2017 | 02/08/2017 |
| UD1 | COMPLETE | 02/08/2017 | 02/10/2017 |
| Note: All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap. | |||
| ZON | COMPLETE | 02/08/2017 | 02/09/2017 |
| BLD | COMPLETE | 02/15/2016 | 02/18/2016 |
| SW1 | COMPLETE | 10/08/2015 | 10/08/2015 |
| Note: Released By: DREWIS foundation survey | |||
| ZON | COMPLETE | 04/02/2015 | 04/02/2015 |
| BLD | COMPLETE | 04/02/2015 | 04/07/2015 |
| ZON | HOLD | 03/26/2015 | 03/27/2015 |
| Note: Per original hold comment, recording information on Site Plan is incorrect. When resubmitting, please also make sure paver driveway note is carried over to corrected site plan. T. Childs 986-2473 | |||
| URB | COMPLETE | 03/26/2015 | 03/26/2015 |
| MECH | COMPLETE | 03/26/2015 | 03/27/2015 |
| BLD | HOLD | 03/26/2015 | 03/27/2015 |
| Note: 1. Provide lintel over openings of front master bathroom window and doors per 2010 FBCR 606.10. 2. Provide Florida product approval for concrete tile roofing material per 2010 FBC 107.2.1 | |||
| SW1 | COMPLETE | 03/26/2015 | 03/27/2015 |
| Note: final s | |||
| ELEC | COMPLETE | 03/26/2015 | 03/27/2015 |
| BLD | HOLD | 03/05/2015 | 03/06/2015 |
| Note: 1. Provide lintel over openings of front windows and doors per 2010 FBCR 606.10. 2. Provide Florida product approval for concrete tile roofing material per 2010 FBC 107.2.1. | |||
| ELEC | HOLD | 03/05/2015 | 03/09/2015 |
| Note: 1. Provide a disconnect for the air handler per 2008 NEC art 422. | |||
| ENGIN1 | COMPLETE | 03/05/2015 | 03/18/2015 |
| MECH | HOLD | 03/05/2015 | 03/06/2015 |
| Note: Clarify the hvac units cooling capacity to be installed per 2010 FBC 107.2.1/ FBCEC 403.6.1.1. The energy calculation shows 3.5 tons but the sizing calculation shows 2.5 tons. | |||
| PLUM | COMPLETE | 03/05/2015 | 03/06/2015 |
| SW1 | HOLD | 03/05/2015 | 03/09/2015 |
| Note: 1. Provide a site plan with the proposed drainage. | |||
| UD1 | COMPLETE | 03/05/2015 | 03/06/2015 |
| Note: See Comments | |||
| URB | HOLD | 03/05/2015 | 03/06/2015 |
| Note: Need foundation shrubbery front of bump-out left side and wrap all corners. | |||
| ZON | HOLD | 03/05/2015 | 03/05/2015 |
| Note: 1. Provide site plan. Please be sure that paver driveway is depicted and that the recording information map book and page number(s) are correct. 2. Foundation plantings are required to wrap front corners of house. T. Childs 986-2473 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 02/17/2017 |
| CONTRACTOR CHANGE | ¤40.00 | 02/17/2017 |
| REVISION | ¤40.00 | 02/17/2017 |
| REINSPECTION FEE | ¤40.00 | 02/17/2017 |
| NEW RESIDENTIAL INSPECTIONS | ¤560.00 | 04/22/2015 |
| ADMIN FEE | ¤20.00 | 04/22/2015 |
| SITE PLAN 20 | ¤20.00 | 04/22/2015 |
| SURCHARGE FS 533.721 | ¤20.64 | 04/22/2015 |
| SURCHARGE - FS 468.631 | ¤20.64 | 04/22/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/22/2015 |
| 3% TRANS IMPACT FEE CREDIT | (¤91.51) | 04/22/2015 |
| ELECTRIC FEE | ¤228.00 | 04/22/2015 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.33) | 04/22/2015 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤211.11 | 04/22/2015 |
| IMPACT FEE PARKS | ¤849.24 | 04/22/2015 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/22/2015 |
| RECORDING FEE REIMBURSE DOC | ¤52.50 | 04/22/2015 |
| IMPACT FEE TRANSPORTATION | ¤3,050.24 | 04/22/2015 |
| MECHANICAL FEE | ¤228.00 | 04/22/2015 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/22/2015 |
| PLAN CHECK FEE | ¤112.00 | 04/22/2015 |
| PLUMBING FEE | ¤228.00 | 04/22/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,317.05 |