Permit #2015030563
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7017-00050-0110 |
| CONDITIONED SPACE: 398 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| Total Square Footage: 486 sqft |
| Block: 00050 |
| Subdivision: 2129 - SECTION 17-BELLE TERRE |
| Job Phone: (386)775-0171 |
| Location Address: 22 BOSTON LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 04/02/2015 |
| NOC: RECORDED |
| Applicant name: FRANK MICHAEL MILLER |
| Owner: ELLIS STEPHEN A |
|
Address 22 BOSTON LANE PALM COAST, FL 32137 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤30,000.00 |
| Job Description: ADDITION OF BATH & DEN |
| Type: CN |
Contractor
F-M BUILDER AND CONSTRUCTION SERVICES LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
613 PINEVIEW DRIVE ORANGE CITY, FL 32763 |
CBC022168 (Exp: 08/31/2022) | (386)775-0171 |
Sub Contractors
STEVEN JAY SMITH
| Status | Location Address | State License Number | Phone |
| INACTIVE |
104 West Cedar Avenue Orange City, FL 32763 |
EC0001542 (Exp: 08/31/2022) | (386)775-7776 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32136 |
CAC048127 (Exp: 08/31/2018) | 386-445-5023 | 386-446-4614 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/14/2015 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL | 08/12/2015 | FINAL APPROVED | MBACON |
| BLD - BUILDING FINAL | 08/10/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 8/10/2015 9:38:25 AM ATTIC ACCESS NEEDS TO BE INSTALLED FIRERATED MATERIAL.FBC. R807......VENTS IN SOFFIT NEED TO BE TRIMMED AND SOLID SOFIT NEEDS TO BE PLACED THREE FEET ON EACH SIDE OF VENT.......FIRE ALARM DID NOT INTERCONNECT OR FUNCTIONED WHEN TESTED. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 08/03/2015 | APPROVED | DREWIS |
| U - SEWER TIE IN | 07/07/2015 | APPROVED | DSPENCER |
| Note: Inspection Resulted at 7/7/2015 10:50:55 AM TIE IN OK | |||
| INSULATION | 06/11/2015 | APPROVED - AS NOTED | JCOLASANTI |
| Note: revision submitted for change in energy calcs from r-5 to r4.1 Inspection Resulted at 6/11/2015 3:08:07 PM TURN IN ENERGY CALCS TO CITY FOR APPROVAL. WILL CHECK AT NEXT INSPECTION | |||
| INSULATION | 06/08/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 6/8/2015 9:02:03 AM ENERGY CALCS CALL FOR R=5.0. INSULATION INSTALLED HAS 4.6 FOR 7/8 CAVITY, NEED TO HAVE CALCS REVISED. NEED TO HAVE INSULATION COMPLETE AT INSPECTION. OFF WALL BY BAR SINK. | |||
| ALL ROUGH | 06/08/2015 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 06/04/2015 | CANCELLED BY APPLICANT | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| INSULATION | 06/04/2015 | CANCELLED BY APPLICANT | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 05/27/2015 | APPROVED | JCOLASANTI |
| ALL ROUGH | 05/27/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 5/27/2015 3:11:56 PM NEED TO ADD SMOKE DETECTOR IN NEW ADDITION AND INTERCONNECTED TO SMOKE/CARBON DETECTOR SO WILL ACTIVATE ALARMS THROUGHOUT RESIDENCE. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/15/2015 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 5/15/2015 9:40:45 AM NEED WASHERS AT GABLE END SILL PLATE. CHECK AT ALL ROUGH. | |||
| TIE BEAM / LINTEL | 05/05/2015 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 05/01/2015 | APPROVED | FREODICA |
| MONOLITHIC SLAB | 04/21/2015 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| MONOLITHIC SLAB | 04/20/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: per contractor Inspection Resulted at 4/20/2015 8:52:40 AM RELIEVING ARCH IN FOOTING NEED TO BEND STEEL OVER PIPE P2603.5........MISSING DOWEL LEFT SIDE FOOTING. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/15/2015 | APPROVED | JCOLASANTI |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 07/31/2015 | 08/03/2015 |
| Note: Released By: DREWIS final s | |||
| MECH | COMPLETE | 06/10/2015 | 06/15/2015 |
| Note: Revision - changed exterior wall insulation from R-5 to R4.1 | |||
| SW1 | COMPLETE | 05/01/2015 | 05/01/2015 |
| Note: Released By: FREODICA foundation s | |||
| PLUM | COMPLETE | 03/30/2015 | 03/30/2015 |
| BLD | COMPLETE | 03/23/2015 | 03/24/2015 |
| ELEC | COMPLETE | 03/23/2015 | 03/24/2015 |
| PLUM | HOLD | 03/23/2015 | 03/25/2015 |
| Note: Previous comment item 1 shall be addressed. 1. Sanitary riser diagram does not match with floor plan. Coordinate and submit correction per 2010 FBC 107.2.1. Please note the floor plan shows future bar sink which is missing on riser diagram. | |||
| ZON | COMPLETE | 03/23/2015 | 03/24/2015 |
| BLD | HOLD | 03/19/2015 | 03/19/2015 |
| Note: 1. Provide a smoke detector in the den. 2010 FBC 202 definition of a bedroom. | |||
| ELEC | HOLD | 03/19/2015 | 03/19/2015 |
| Note: 1. Provide a smoke detector in the den. 2010 FBC 202 definition of a bedroom. | |||
| MECH | COMPLETE | 03/19/2015 | 03/19/2015 |
| PLUM | HOLD | 03/19/2015 | 03/19/2015 |
| Note: 1. Sanitary riser diagram does not match with floor plan. Coordinate and submit correction per 2010 FBC 107.2.1. 2. The lavatory shall be vented either wet vented per 2010 FBCR P3108 or individually vented per P3106. | |||
| SW1 | COMPLETE | 03/19/2015 | 03/19/2015 |
| ZON | HOLD | 03/19/2015 | 03/20/2015 |
| Note: Site plan must depict proposed A/C Pad and demonstrate that it does not encroach into the 5' utility easement. T. Childs 986-2473 | |||
| BLD | HOLD | 03/19/2015 | |
| Note: 1. Provide a gable bracing detail 2010 FBC R 609.4. | |||
| ELEC | HOLD | 03/19/2015 | |
| Note: 1. The plan cannot show an optional electric circuit. 2010 FBC 107.2.1. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/13/2015 |
| REINSPECTION FEE | ¤40.00 | 08/13/2015 |
| REINSPECTION FEE | ¤40.00 | 08/13/2015 |
| REINSPECTION FEE | ¤40.00 | 08/13/2015 |
| REVISION | ¤40.00 | 08/13/2015 |
| SITE PLAN 20 | ¤20.00 | 04/02/2015 |
| SURCHARGE FS 533.721 | ¤5.50 | 04/02/2015 |
| SURCHARGE - FS 468.631 | ¤5.50 | 04/02/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/02/2015 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 04/02/2015 |
| ADMIN FEE | ¤20.00 | 04/02/2015 |
| ELECTRIC FEE | ¤88.80 | 04/02/2015 |
| MECHANICAL FEE | ¤88.80 | 04/02/2015 |
| PLAN CHECK FEE | ¤40.00 | 04/02/2015 |
| PLUMBING FEE | ¤88.80 | 04/02/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤677.40 |