Permit #2015040240

Permit Details

Status: COED

Parcel Id: 07-11-31-7015-00030-1530
CONDITIONED SPACE: 2408 sqft
GARAGE: 670 sqft
OPENED PORCH (WITH ROOF) : 408 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
Total Square Footage: 3596 sqft
Block: 00030
Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE
Job Phone: (386)445-9393
Location Address: 13 CALUSA CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/08/2015
NOC: RECORDED
Applicant name: ANTONIO AMARAL JR
Owner: CONCEICAO, ROSE C & ALBERT

Address

35 CORMORANT COURT

PALM COAST, FL 32137

Lot: 1530
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

AMARAL CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32135

CBC058062 (Exp: 08/31/2020) (386)445-9393 (386)446-0403

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ANTONIO JR AMARAL
Status Location Address State License Number Phone Fax
CANCEL

13 Utility Drive

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2018) (386)445-9393 (386)446-0403

Inspection History

Type Request Date Result Inspector
STORMWATER FINAL 03/16/2016 FINAL APPROVED RGROSS
Note: APPROVED
U -UTILITY RESIDENTIAL FINAL 03/16/2016 FINAL APPROVED MBACON
BLD - BUILDING FINAL 03/15/2016 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
ROW FINAL 03/15/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION APPROVED
BLD - BUILDING FINAL 03/11/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 3/11/2016 3:32:21 PM PIPES (SPACES AROUND) MUST BE SEALED….SEALING OF ANNULAR SPACES…P2606.1 (BACK PORCH)..... WATER LEAK UNDER BATHROOM SINK (BATHROOM NEAR KITCHEN).... (FYI-TOILET OFF PORCH WILL NOT STOP RUNNING,NO FLUSH HANDLE ON TOILET UP STAIRS, UP STAIRS BATH TUB MISSING CAULK) (BACK SIDE).... OUTLET COVER MISSING.... HOLES IN WALLS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 .... MOCP RATING NOT MATCHING BREAKERS MFBC 1303
BLD - BUILDING FINAL 03/10/2016 CANCELLED BY APPLICANT CMINI
FINAL APRON (AFTER POUR/DRIVEWAY) 03/09/2016 APPROVED RGROSS
Note: APPROVED
ROW FINAL 03/09/2016 Disapproved -FEE REQUIRED RGROSS
Note: SEED AND STRAW ALL EXPOSED EARTH AREA ON THE LEFT SIDE EASEMENT TO PREVENT WASHOUT. STORMWATER DRAINS FROM GUTTERS CANNOT DRAIN DIRECTLY INTO THE INTERCOASTAL WATERS.
FINAL SURVEY (OFFICE USE ONLY) 03/08/2016 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 03/07/2016 Disapproved - NO FEE DREWIS
Note: Western invert is lower than approved limit of swale diagram. -DC. Rewis 986-4736
ELECTRIC - EARLY POWER 02/15/2016 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 2/15/2016 12:51:03 PM NEED APPROVED ELECTRIC REVISION ON SITE FOR INSPECTION SHOWING SUBPANEL/GENERATOR PANEL
PRE-APRON (PRE-POUR/DRIVEWAY) 01/29/2016 APPROVED GLALIMA
Note: READY TO POUR
U - SEWER TIE IN 01/19/2016 APPROVED DSPENCER
GRAVITY SEWER TEST 01/19/2016 APPROVED CMINI
INSULATION 11/10/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
INSULATION 11/09/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 11/9/2015 11:20:45 AM NOT READY
ALL ROUGH 10/26/2015 APPROVED - AS NOTED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 10/26/2015 11:21:40 AM ELECTRIC REVISION TO MATCH BY NEXT INSPECTION. SUPPORT WIRES IN ATTIC IN LAUNDRY RM EVERY 4-1/2`` NEC 334.30. FRAME IN PANELS. CHECK ALL ON INSULATION
ALL ROUGH 10/22/2015 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 10/22/2015 11:48:01 AM INCOMPLETE INSPECTION;...... CONDITIONS AT SITE DO NOT MATCH WITH REVISIONS DATED 01-28-15, NEED REVISIONS THAT MATCH CONDITIONS AT SITE.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/20/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 10/20/2015 CANCELLED BY APPLICANT CMINI
LATH/BRICK/ WATER BARRIER 10/20/2015 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/21/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 9/21/2015 11:18:27 AM COULD NOT PULL APART PLANS IN BOX, NEED TO ORGANIZE BOX AND HAVE LEGIBLE APPROVED SET.
WALL SHEATHING 09/04/2015 APPROVED LMILLER
Note: THIS IS A REINSPECTION
WALL SHEATHING 09/03/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 9/3/2015 11:10:23 AM NAILING NOT COMPLETE,CHECK ALL AND NAIL PER PLAN
TIE BEAM / LINTEL 08/06/2015 APPROVED CMINI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 08/05/2015 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 8/5/2015 12:04:57 PM STILL MISSING RODS, CIRCLED ON PLAN
TIE BEAM / LINTEL 08/04/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 8/4/2015 11:50:47 AM NEED TO DRILL AND EPOXY ALL UPRIGHTS MISSING PER PLAN AND ALL UPRIGHTS THAT ARE OUT OF CELL, PLUMBING STACK NOT ATTACHED, CHECK ALL
ELEV CERT-FOUNDATION APPROVAL 08/03/2015 APPROVED CBENTLEY
FOUND SURVEY APPROVED (OFFICE) 07/28/2015 APPROVED DREWIS
MONOLITHIC SLAB 07/08/2015 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 07/02/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION per contractor
PLUMBING 1ST ROUGH UNDERGROUND 07/01/2015 CANCELLED BY APPLICANT CMINI
Note: Inspection Resulted at 7/1/2015 10:16:39 AM ]
RETAINING WALL 06/24/2015 APPROVED CMINI
RETAINING WALL FOUNDATION 06/10/2015 APPROVED CMINI

Review History

Department Status Date In Date Out
ELEC COMPLETE 03/08/2016 03/09/2016
Note: Released By: DREWIS
PLFM COMPLETE 03/07/2016 03/10/2016
Note: Released By: CBENTLEY no floodplain review needed for electrical revision
SW1 HOLD 03/04/2016 03/07/2016
Note: Held By: DREWIS Western invert is lower than approved limit of swale diagram. -DC. Rewis 986-4736
ELEC HOLD 02/26/2016 02/29/2016
Note: Held By: DREWIS Please provide additional GFCI in guest bath NEC 2008 210.52 D. -DC. Rewis 986-4736
ZON COMPLETE 01/08/2016 01/08/2016
Note: Released By: TCHILDS
PLFM COMPLETE 08/03/2015 08/03/2015
BLD COMPLETE 07/28/2015 07/28/2015
SW1 COMPLETE 07/28/2015 07/28/2015
Note: Released By: DREWIS foundation s
PLFM COMPLETE 06/03/2015 06/04/2015
ZON COMPLETE 06/03/2015 06/04/2015
BLD COMPLETE 05/22/2015 05/29/2015
PLFM HOLD 05/22/2015 05/22/2015
Note: Either revise the survey to remove the AE special flood hazard area if warranted or the elevation certificate needs to show the highest risk zone AE in Section B8 but the comment section can explain that the house lies within the X.
ELEC COMPLETE 05/22/2015 06/01/2015
URB COMPLETE 05/22/2015 05/26/2015
ZON HOLD 05/22/2015 05/22/2015
Note: Repeat Comment: Footprint of home does not match the site plan with the blueprints in the left rear area of the home. There is a bay window shape on the site plan that is not shown on the blueprints. Please submit revised site plan.
PLUM COMPLETE 05/22/2015 05/28/2015
PLFM HOLD 04/09/2015 04/10/2015
Note: Property lies within a special flood hazard area AE. Provide an elevation certificate.
BLD HOLD 04/08/2015 04/10/2015
Note: 1. Provide attic access per 2010 FBCR 807. 2. Provide specific roof sheathing thickness as details show 2 different sizes per 2010 FBC 107.2.1. 3. Plan shows habitable space above garage to be 1/2 inch thick drywall which does not meet code per 2010 FBCR 302.6. 4. Details show both vented and unvented attic with different type of insulation. Clarify which one to be used and coordinate with energy calculations per 2010 FBC 107.2.1. If unvented, provide specifications of spray foam insulation.
ELEC HOLD 04/08/2015 04/13/2015
Note: 1. Provide GFCI protection at exterior receptacles 2008 NEC 210.8. 2. Provide a smoke detector at the top stair landing. 2010 FBC R 314.3. 3. Provide GFCI receptacles at the bonus room bath vanity. 2008 NEC 210.8 and 210.11. 4. Provide a electrical symbol legend 2010 FBC 107.2.1..
ENGIN1 COMPLETE 04/08/2015 04/09/2015
Note: Swale plan to be issued at a later date.
MECH COMPLETE 04/08/2015 04/09/2015
PLUM HOLD 04/08/2015 04/09/2015
Note: Sanitary riser diagram does not match with floor plan. Coordinate and submit correction per 2010 FBC 107.2.1.
SW1 COMPLETE 04/08/2015 04/08/2015
UD1 COMPLETE 04/08/2015 04/09/2015
Note: See Comments
URB HOLD 04/08/2015 04/09/2015
Note: Need to indicate the type of and gallon container size of trees 2 shade and 3 understory 30 gal. 5 required and up the size of crape myrtle from 3' to min. 6' to 7' tall. Need gallon size of shrubbery 3 gal foundation and 7 gal. 30" tall @ A/C unit. Need to indicate the type of sod / irrigation
ZON HOLD 04/08/2015 04/09/2015
Note: 1. Revise landscape plan to provide the following: - Lot requires 5 replacement trees. - Sod type must be depicted. If St. Augustine sod is being used, an irrigation system must be installed. - A/C unit must be screened on front and side. - Foundation plantings are required along side and/or rear of home (to include lanai area) facing salt water canal. 2. Footprint of home does not match the site plan with the blueprints in the left rear area of the home. There is a bay window shape on the site plan that is not shown on the blueprints. Please revise and resubmit whichever is incorrect.
SW1 COMPLETE 03/08/2016
Note: Released By: DREWIS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REINSPECTION FEE ¤40.00 03/17/2016
REVISION ¤40.00 03/17/2016
REVISION ¤40.00 03/17/2016
SITE PLAN 20 ¤20.00 06/08/2015
SURCHARGE FS 533.721 ¤22.91 06/08/2015
SURCHARGE - FS 468.631 ¤22.91 06/08/2015
STORM WATER PERMIT FEES ¤80.00 06/08/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 06/08/2015
NEW RESIDENTIAL INSPECTIONS ¤632.00 06/08/2015
ADMIN FEE ¤20.00 06/08/2015
ELECTRIC FEE ¤249.60 06/08/2015
3% FIRE IMPACT FEE CREDIT (¤6.33) 06/08/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 06/08/2015
IMPACT FEE PARKS ¤849.24 06/08/2015
IMPACT FEE SCHOOL ¤3,600.00 06/08/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 06/08/2015
MECHANICAL FEE ¤249.60 06/08/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/08/2015
PLAN CHECK FEE ¤126.40 06/08/2015
PLUMBING FEE ¤249.60 06/08/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,620.29