Permit #2015040374
Permit Details
Status: COED
| Parcel Id: 18-11-31-0000-02010-0070 |
| Block: 02010 |
| Subdivision: - |
| Job Phone: (386) 445-4350 |
| Location Address: 5 UTILITY DR |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 06/12/2015 |
| NOC: RECORDED |
| Applicant name: MICHAEL GLEN MACHIN |
| Owner: M MACHIN ENTERPRISES INC |
|
Address P O BOX 353460 PALM COAST, FL 32135 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤39,000.00 |
| Job Description: UNITS #24-27 " DAYCARE" INTERIOR RENOVATIONS |
| Type: CN |
Contractor
MACHIN CONSTRUCTION CO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3 HARGROVE GRADE SUITE 1 Palm Coast, FL 32137 |
CGC058789 (Exp: 08/31/2024) | (386) 445-4350 | (386)446-5459 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
317 RIO PINR DR Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2026) | 386-233-1553 | 386-673-5994 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
PAUL S AIELLO
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
PO BOX 351926 PALM COAST, FL 32137 |
CAC1815808 (Exp: 08/31/2016) | (386)239-0053 | (386)323-1955 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC FINAL | 09/02/2015 | FINAL APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION | |||
| BUILDING FINAL | 09/02/2015 | APPROVED | JHINDMAN |
| FIRE FINAL | 09/02/2015 | APPROVED | JHINDMAN |
| U - UTILITY COMMERCIAL FINAL | 09/01/2015 | FINAL APPROVED | JNICHOLS |
| ELECTRIC FINAL | 09/01/2015 | Disapproved -FEE REQUIRED | RMARTIN |
| Note: Inspection Resulted at 9/1/2015 11:50:45 AM PANELS NEED TO BE LABELED A,B,C PER PLAN, PANEL SCHEDULE DOES NOT MATCH PANEL A OR C, MLCP ON CONDENSOR IS 50 THERE IS A 60 INSTALLED PER DOOR ON PANEL NEC 240 | |||
| PLUMBING FINAL | 08/28/2015 | APPROVED | CMINI |
| HVAC FINAL | 08/28/2015 | APPROVED | CMINI |
| ELECTRIC 2ND ROUGH | 07/20/2015 | APPROVED - AS NOTED | RMARTIN |
| Note: Inspection Resulted at 7/20/2015 9:30:35 AM NEED TO GROUND 5 GANG SWITCH BOX BY FRONT DOOR | |||
| HVAC ROUGH | 07/20/2015 | APPROVED | CMINI |
| FRAMING | 07/20/2015 | APPROVED | CMINI |
| ABOVE CEILING | 07/20/2015 | APPROVED | CMINI |
| MONOLITHIC SLAB | 07/07/2015 | APPROVED | DROCKWELL |
| PLUMBING 1ST ROUGH | 07/01/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 2ND ROUGH | 07/01/2015 | APPROVED | CMINI |
| Note: THIS IS A REINSPECTION | |||
| PLUMBING 1ST ROUGH | 06/29/2015 | Disapproved -FEE REQUIRED | JHINDMAN |
| Note: provide test pressure on sanitary | |||
| PLUMBING 2ND ROUGH | 06/29/2015 | Disapproved - NO FEE | JHINDMAN |
| Note: provide test pressure on sanitary |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 08/26/2015 | 08/31/2015 |
| ELEC | COMPLETE | 07/16/2015 | 07/17/2015 |
| PLUM | COMPLETE | 06/03/2015 | 06/09/2015 |
| BLD | COMPLETE | 06/03/2015 | 06/09/2015 |
| ELEC | COMPLETE | 06/03/2015 | 06/09/2015 |
| FI1 | COMPLETE | 06/03/2015 | 06/09/2015 |
| MECH | COMPLETE | 06/03/2015 | 06/09/2015 |
| MECH | HOLD | 04/15/2015 | 04/17/2015 |
| Note: 1. Provide hvac contractor doing the work per FS 489. 2. Provide existing and proposed hvac plans suitable for review, construction and inspections signed and sealed by Florida registered engineer per 2010 FBC 107.2.1. 3. Provide energy calculations due to change in occupancy use of the proposed space per 2010 FBCEC 101.4.3. Note: Additional review comments maybe added upon submission of the required documents. | |||
| BLD | HOLD | 04/13/2015 | 04/17/2015 |
| Note: 1. This is a complete change of occupancy classification and must comply with the 2010 FBC Existing code chapter 9. 2. Provide rated corridor wall that comply with 2010 FBC 436.8. 3. Provide exit travel distances and exit width requirements per 2010 FBC ch. 10. 4. Provide one hour rated walls at laundry room. per 436.6.2. 5. Provide a separate fire alarm permit which has smoke detectors installed per 2010 FBC 436.7.2. | |||
| ELEC | HOLD | 04/13/2015 | 04/17/2015 |
| Note: 1. Provide a revised lighting plan for the corridors that have to be enclosed by rated walls per the building hold comments. | |||
| FI1 | HOLD | 04/13/2015 | 04/17/2015 |
| Note: 1. Provide panic hardware at the main entrance per the 5th edition of the Florida Fire Prevention code 101 16.2.2.2.2. 2. Provide fire extinguisher locations per NFPA 10. | |||
| PLUM | HOLD | 04/13/2015 | 04/15/2015 |
| Note: 1. Provide calculation showing the minimum number of required plumbing fixtures per 2010 FBCP Table 403.1. | |||
| SW1 | COMPLETE | 04/13/2015 | 04/13/2015 |
| UD1 | COMPLETE | 04/13/2015 | 04/16/2015 |
| ZON | COMPLETE | 04/13/2015 | 04/16/2015 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/01/2015 |
| REVISION | ¤40.00 | 08/31/2015 |
| REVISION | ¤40.00 | 08/31/2015 |
| REINSPECTION FEE | ¤40.00 | 08/31/2015 |
| SITE PLAN 20 | ¤20.00 | 06/12/2015 |
| SURCHARGE FS 533.721 | ¤6.15 | 06/12/2015 |
| SURCHARGE - FS 468.631 | ¤6.15 | 06/12/2015 |
| ADMIN COMMERCIAL | ¤60.00 | 06/12/2015 |
| INSPECTION - COMMERCIAL ADD | ¤273.00 | 06/12/2015 |
| ELECTRIC FEE | ¤83.40 | 06/12/2015 |
| FIRE PLANS REVIEW | ¤25.00 | 06/12/2015 |
| MECHANICAL FEE | ¤83.40 | 06/12/2015 |
| PLAN CHECK FEE | ¤100.00 | 06/12/2015 |
| PLUMBING FEE | ¤83.40 | 06/12/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤900.50 |