I want to search for...

Permit #2015040638

Permit Details

Status: COED

Parcel Id: 07-11-31-7014-00020-1030
CONDITIONED SPACE: 2453 sqft
GARAGE: 506 sqft
OPENED PORCH (WITH ROOF) : 315 sqft
OPENED PORCH (WITH ROOF) : 109 sqft
Total Square Footage: 3383 sqft
Block: 00020
Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE
Job Phone: (386)446-5161
Location Address: 51 COLLINGWOOD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/29/2015
NOC: RECORDED
Applicant name: HUGO A CAMACHO
Owner: CHENG XU JIN

Address

25 CLERMONT CT

PALM COAST, FL 32137

Lot: 1030
Contracted Stated Job Value: ¤285,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

IDEAL HOMES AT PALM COAST, INC.
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 353639

PALM COAST, FL 32137

CBC1250774 (Exp: 08/31/2026) (386)446-5161 (386)447-0238

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 05/19/2016 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 05/18/2016 FINAL APPROVED CMINI
FINAL APRON (AFTER POUR/DRIVEWAY) 04/28/2016 APPROVED GLALIMA
Note: PER HUGO
ROW FINAL 04/28/2016 APPROVED - AS NOTED GLALIMA
Note: YOU NEED TO GET THE SEAWALL GUY BACK AND REPAIR THE SEEM / GAP ''' RIGHT REAR
FINAL SURVEY (OFFICE USE ONLY) 04/07/2016 APPROVED DREWIS
ELECTRIC - EARLY POWER 02/23/2016 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 2/23/2016 1:55:36 PM SPOKE TO SUSAN FPL RELEASED EARLY POWER 2:00
PRE-APRON (PRE-POUR/DRIVEWAY) 02/22/2016 APPROVED RGROSS
Note: THIS IS A REINSPECTION READY TO POUR AND PLACE PAVERS.
PRE-APRON (PRE-POUR/DRIVEWAY) 02/18/2016 Disapproved -FEE REQUIRED GLALIMA
Note: # 1 COULD NOT SEE EDGE OF ROAD BECAUSE OF DAMAGE # 2 REMOVE TOILET FROM THE END OF CULVERT PIPE # 2 SO WE CAN SEE THE CENTER LINE OF SWALE AND BASIN . AND YOU DID NOT SHOW ME THE LOCATION OF EDGE OF ROAD. SO CLEAN IT UP THANK YOU ''''' 3 PICTURE
U - SEWER TIE IN 01/27/2016 APPROVED MBACON
GRAVITY SEWER TEST 01/27/2016 APPROVED CMINI
INSULATION 11/24/2015 APPROVED LMILLER
Note: THIS IS A REINSPECTION
INSULATION 11/23/2015 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 11/23/2015 11:56:10 AM NEED FOAM AT ELECTRIC THROUGH GARAGE FRAMED WALL, AND AT TOP BAND IN BEDROOMS 2, AND 3 EMPTY HOLES FOR WIRE HOLES DRILLED FOR WIRE: FIREBLOCKING R302.11 (4) PIPES, DUCTS, CABLES, AND WIRES AT CEILING AND FLOOR LEVEL(WITH APPROVED MATERIAL)
LATH/BRICK/ WATER BARRIER 11/20/2015 APPROVED CMINI
ALL ROUGH 11/17/2015 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 11/17/2015 10:45:19 AM NEED TO PHASE OUT HOT CONDUCTORS IN PANEL.210.5(C).. THERAPUTIC SPA MOTOR NEEDS TO BE BONDED AT LUG THAT IS SUPPLIED. NEC 680.62(2)B BONDING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/27/2015 APPROVED CMINI
ELECTRIC-TUG 09/11/2015 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 9/11/2015 3:34:29 PM SPOKE TO SUSAN FPL RELEASED POWER 1:50
TIE BEAM / LINTEL 09/10/2015 APPROVED DROCKWELL
FOUND SURVEY APPROVED (OFFICE) 09/08/2015 APPROVED DREWIS
MONOLITHIC SLAB 08/21/2015 APPROVED CMINI
PLUMBING 1ST ROUGH UNDERGROUND 08/19/2015 APPROVED DROCKWELL

Review History

Department Status Date In Date Out
SW1 COMPLETE 04/06/2016 04/07/2016
Note: Released By: DREWIS FINAL S
ZON COMPLETE 03/11/2016 03/15/2016
ENGIN1 COMPLETE 02/02/2016 02/04/2016
SW1 COMPLETE 02/02/2016 02/02/2016
UD1 COMPLETE 02/02/2016 02/03/2016
Note: See original notes.
ZON COMPLETE 02/02/2016 02/03/2016
BLD COMPLETE 10/26/2015 10/26/2015
Note: Revision- Truss repair on trusses T28, T29, T30 and T37.
SW1 COMPLETE 09/08/2015 09/08/2015
Note: Released By: DREWIS foundation s
BLD COMPLETE 08/12/2015 08/14/2015
BLD HOLD 07/08/2015 07/08/2015
Note: Revision Provide elevation drawings affected by the changes per 2010 FBC 107.2.1.
ENGIN1 COMPLETE 07/08/2015 07/08/2015
UD1 COMPLETE 07/08/2015 07/09/2015
ZON COMPLETE 07/08/2015 07/14/2015
URB COMPLETE 04/28/2015 04/28/2015
Note: FYI the HVAC needs the 7 gal. 30" tall @ planting (E) and foundation needs 3 gal. shrubbery
ZON COMPLETE 04/28/2015 04/28/2015
BLD COMPLETE 04/21/2015 04/21/2015
ELEC COMPLETE 04/21/2015 04/21/2015
ENGIN1 COMPLETE 04/21/2015 04/22/2015
Note: Swale plan to be issued at a later date.
MECH COMPLETE 04/21/2015 04/21/2015
PLUM COMPLETE 04/21/2015 04/21/2015
SW1 COMPLETE 04/21/2015 04/21/2015
UD1 COMPLETE 04/21/2015 04/22/2015
Note: See Comments
URB HOLD 04/21/2015 04/22/2015
Note: Foundation shrubs are required for the rear of house.
ZON HOLD 04/21/2015 04/22/2015
Note: 1. Foundation plantings are required along rear of home facing saltwater canal. 2. Banding is required around all windows and doors facing saltwater canal.
BLD COMPLETE 07/09/2015
Note: Revision

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 05/20/2016
REVISION ¤40.00 05/20/2016
REVISION ¤40.00 05/20/2016
REINSPECTION FEE ¤40.00 05/20/2016
REINSPECTION FEE ¤40.00 05/20/2016
NEW RESIDENTIAL INSPECTIONS ¤620.00 04/29/2015
SITE PLAN 20 ¤20.00 04/29/2015
SURCHARGE FS 533.721 ¤22.53 04/29/2015
SURCHARGE - FS 468.631 ¤22.53 04/29/2015
STORM WATER PERMIT FEES ¤80.00 04/29/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 04/29/2015
ADMIN FEE ¤20.00 04/29/2015
ELECTRIC FEE ¤246.00 04/29/2015
3% FIRE IMPACT FEE CREDIT (¤6.33) 04/29/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤211.11 04/29/2015
IMPACT FEE PARKS ¤849.24 04/29/2015
IMPACT FEE SCHOOL ¤3,600.00 04/29/2015
RECORDING FEE REIMBURSE DOC ¤52.50 04/29/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 04/29/2015
MECHANICAL FEE ¤246.00 04/29/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/29/2015
PLAN CHECK FEE ¤124.00 04/29/2015
PLUMBING FEE ¤246.00 04/29/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,486.83