I want to search for...
Permit #2015050518
Permit Details
Status: COED
| Parcel Id: 48-11-31-1710-00000-0340 |
| CONDITIONED SPACE: 2641 sqft |
| GARAGE: 604 sqft |
| OPENED PORCH (WITH ROOF) : 372 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 3649 sqft |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: 386-236-4133 |
| Location Address: 16 SCARLET OAK CIR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/18/2015 |
| NOC: RECORDED |
| Applicant name: KEVIN MICHAEL MAYS |
| Owner: INTERVEST CONSTRUCTION INC |
|
Address 2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤333,672.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INTERVEST CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2379 BEVILLE ROAD DAYTONA BEACH, FL 32119 |
CGC1517573 (Exp: 08/31/2018) | 386-236-4133 | 386-763-7833 |
Sub Contractors
STEPHEN COURTEAUX
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
85 North Yonge Street Ormond Beach, FL 32174 |
EC13001748 (Exp: 08/31/2026) | (386) 672-4900 | 386-676-7472 |
CHRIS C KOONTZ
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
651 CARSWELL AVE Holly Hill, FL 32117 |
CAC035563 (Exp: 08/31/2024) | (386) 252-1878 | (386)252-9703 |
GARY WAYNE EVERS
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 740106 ORANGE CITY, FL 32763 |
CFC050566 (Exp: 08/31/2026) | 386-775-0909 | 386-775-0918 |
BARRY D MARTIN
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
1650 N STATE STREET Bunnell, FL 32110 |
CCC033728 (Exp: 08/31/2020) | (386) 437-7700 | (386)437-7701 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 12/07/2015 | FINAL APPROVED | JNICHOLS |
| BLD - BUILDING FINAL | 12/04/2015 | FINAL APPROVED | LMILLER |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 12/03/2015 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 12/3/2015 2:03:24 PM FLEX DUCT THRU FIRE RATED ASSEMBLY PROHIBITED.. FLOOR,CEILING,WALL.FBC.R..M1601.1.2.7. HOLES IN WALLS MUST BE SEALED: FBC ENERGY CONSERVATION RESIDENTIAL PROVISIONS CHAPTER 4- R402.4.1 BUILDING THERMAL ENVELOPE, R402.4 1.1 AIR LEAKAGE (MANDATORY). INSTALLATION, R402.4, OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED FBC. R302.5. WEATHER STRIPPING NEEDS TO BE INSTALLED FOR FINAL ON DOORS R 612.12 FBC | |||
| ROW FINAL | 12/02/2015 | APPROVED | CTROHA |
| ELECTRIC - EARLY POWER | 11/19/2015 | APPROVED - AS NOTED | CMINI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 11/19/2015 2:48:18 PM CALLED DELL FROM FPL TO RELEASE POWER | |||
| ELECTRIC - EARLY POWER | 11/18/2015 | CANCELLED BY APPLICANT | RMARTIN |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/17/2015 | APPROVED - AS NOTED | GLALIMA |
| Note: WILL CHECK FINAL SERVEY AT TIME OF ROW INSPECTIONS, FOR GRADE ELEVATIONS AND DRIVEWAY PLACEMENT | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/13/2015 | APPROVED | DREWIS |
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/29/2015 | APPROVED | GLALIMA |
| Note: THIS IS A REINSPECTION | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 10/28/2015 | PARTIALLY APPROVED | GLALIMA |
| Note: PRE APRON AND SIDE WALKS | |||
| INSULATION | 10/02/2015 | APPROVED | DROCKWELL |
| LATH/BRICK/ WATER BARRIER | 10/02/2015 | APPROVED | DROCKWELL |
| ALL ROUGH | 09/29/2015 | APPROVED - AS NOTED | DROCKWELL |
| Note: Inspection Resulted at 9/29/2015 2:17:03 PM FILL GUEST TUB BOX WITH APPROVED MATERIAL | |||
| WALL SHEATHING | 09/23/2015 | APPROVED | CMINI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/22/2015 | APPROVED | DROCKWELL |
| Note: Inspection Resulted at 9/22/2015 3:06:04 PM CHECK THAT KNEE WALLS AT ENTRY ARE ANCHORED | |||
| TIE BEAM / LINTEL | 08/11/2015 | APPROVED | DROCKWELL |
| ELECTRIC-TUG | 08/11/2015 | APPROVED - AS NOTED | RMARTIN |
| Note: Inspection Resulted at 8/11/2015 11:52:15 AM SPOKE TO SUSAN AT FPL RELEASED POWER FOR TUG 11:50 | |||
| GRAVITY SEWER TEST | 08/07/2015 | APPROVED | CMINI |
| ELEV CERT-FOUNDATION APPROVAL | 08/07/2015 | APPROVED | CBENTLEY |
| FOUND SURVEY APPROVED (OFFICE) | 08/07/2015 | APPROVED | DREWIS |
| U - SEWER TIE IN | 08/07/2015 | APPROVED | MBACON |
| MONOLITHIC SLAB | 07/22/2015 | APPROVED | CMINI |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/20/2015 | APPROVED | CMINI |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 11/30/2015 | 11/30/2015 |
| PLFM | HOLD | 11/20/2015 | 11/23/2015 |
| Note: 1. Revise Section B9 to 10ths. | |||
| PLFM | HOLD | 11/18/2015 | 11/19/2015 |
| Note: Held By: CBENTLEY 1. During a recent audit of the elevation certificates Floodplain Managment Staff was informed by FEMA that Section B9 had to be in 10ths. Please revise the elevation certificate to show 10ths rather than the 9'. | |||
| SW1 | COMPLETE | 11/13/2015 | 11/13/2015 |
| Note: Released By: DREWIS final survey | |||
| PLFM | COMPLETE | 08/07/2015 | 08/07/2015 |
| BLD | COMPLETE | 08/07/2015 | 08/07/2015 |
| SW1 | COMPLETE | 08/06/2015 | 08/07/2015 |
| Note: Released By: DREWIS foundation s | |||
| BLD | HOLD | 07/01/2015 | 07/01/2015 |
| Note: 1. Provide Florida product approval for the new door. | |||
| MECH | COMPLETE | 06/16/2015 | 06/16/2015 |
| MECH | HOLD | 06/15/2015 | 06/15/2015 |
| Note: Previous comment item 2 shall be addressed. 2. Provide the efficiency rating of selected hvac units from the manufacturer's performance data per 2010 FBCEC 403.6.2.1. | |||
| PLFM | COMPLETE | 05/20/2015 | 05/20/2015 |
| BLD | COMPLETE | 05/18/2015 | 05/19/2015 |
| ELEC | COMPLETE | 05/18/2015 | 05/19/2015 |
| ENGIN1 | COMPLETE | 05/18/2015 | 05/19/2015 |
| Note: No swale plan required. | |||
| MECH | HOLD | 05/18/2015 | 05/19/2015 |
| Note: 1. Provide balanced return air from study room per 2010 FBCR M 1602.4. 2. Provide the efficiency rating of selected hvac units from the manufacturer's performance data per 2010 FBCEC 403.6.2.1. | |||
| PLUM | COMPLETE | 05/18/2015 | 05/19/2015 |
| SW1 | COMPLETE | 05/18/2015 | 05/18/2015 |
| UD1 | COMPLETE | 05/18/2015 | 05/19/2015 |
| Note: See Notes | |||
| ZON | COMPLETE | 05/18/2015 | 05/20/2015 |
| URB | COMPLETE | 05/18/2015 | 05/19/2015 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/10/2015 |
| REVISION | ¤40.00 | 12/03/2015 |
| SITE PLAN 20 | ¤20.00 | 06/18/2015 |
| SURCHARGE FS 533.721 | ¤24.04 | 06/18/2015 |
| SURCHARGE - FS 468.631 | ¤24.04 | 06/18/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/18/2015 |
| 3% TRANS IMPACT FEE CREDIT | (¤91.51) | 06/18/2015 |
| NEW RESIDENTIAL INSPECTIONS | ¤668.00 | 06/18/2015 |
| ADMIN FEE | ¤20.00 | 06/18/2015 |
| ELECTRIC FEE | ¤260.40 | 06/18/2015 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.33) | 06/18/2015 |
| IMPACT FEE FIRE NONRESIDENTIAL | ¤211.11 | 06/18/2015 |
| IMPACT FEE PARKS | ¤849.24 | 06/18/2015 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 06/18/2015 |
| IMPACT FEE TRANSPORTATION | ¤3,050.24 | 06/18/2015 |
| MECHANICAL FEE | ¤260.40 | 06/18/2015 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 06/18/2015 |
| PLAN CHECK FEE | ¤133.60 | 06/18/2015 |
| PLUMBING FEE | ¤260.40 | 06/18/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,418.15 |