I want to search for...
Permit #2015050932
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7081-00280-0050 |
| Block: 00280 |
| Subdivision: 2183 - SECTION 81-BERNARD MEADOWS-PALM HARBOR |
| Job Phone: 386-931-0627 |
| Location Address: 95 BLARE CASTLE DR |
| Type: DR - DRIVEWAY |
| Issue Date: 06/25/2015 |
| NOC: Unknown |
| Applicant name: FERNANDO FERNANDES |
| Owner: RAGNAUTH, DYANAND |
|
Address 95 BLARE CASTLE DRIVE PALM COAST, FL 32137 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤1,800.00 |
| Job Description: CONCRETE CIRCULAR DRIVEWAY ADDITION |
| Type: CN |
Contractor
HIGH TECH CONCRETE INC
| Status | Location Address | Phone |
| CANCEL |
PO BOX 351726 BUNNELL, FL 32110 |
386-931-0627 |
Inspection History
| Type | Request Date | Result | Inspector |
| STORMWATER FINAL | 11/02/2015 | APPROVED | RGROSS |
| ROW DAMAGE | 11/02/2015 | APPROVED | RGROSS |
| FINAL APRON (AFTER POUR/DRIVEWAY) | 11/02/2015 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 11/02/2015 | FINAL APPROVED | JNICHOLS |
| Note: per contractor | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/15/2015 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION Noted that the apron had to meet the 8% slope and did. | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/14/2015 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION Apron too steep. Cannot be more than 8%. Apron flares must be a minimum of 36 inches | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/13/2015 | Disapproved -FEE REQUIRED | RGROSS |
| Note: THIS IS A REINSPECTION Not 4 inches thick throughout the pour beyond the ROW. Driveway wider than the approved permit allows One pipe of the circular more than 8 ft from the road edge | |||
| PRE-APRON (PRE-POUR/DRIVEWAY) | 07/09/2015 | Disapproved -FEE REQUIRED | GLALIMA |
| Note: NEED TO REMOVE CONCRETE ON LEFT DRIVEWAY APRON, ON RIGHT SIDE UPPER DRIVEWAY YOU NEED TO BRING THE GRADE / SLOPE DOWN BECAUSE IT'S HIGHER THEN THE SIDEWALK AND EXISTING GRADE . SITE MEET NEEDED . |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 06/19/2015 | 06/19/2015 |
| ENGIN1 | COMPLETE | 06/19/2015 | 06/19/2015 |
| ENGIN1 | HOLD | 05/29/2015 | 06/02/2015 |
| Note: Culvert replacement required for work on existing d/w. Scott Bombardier 986-3756 | |||
| SW1 | COMPLETE | 05/29/2015 | 06/05/2015 |
| UD1 | COMPLETE | 05/29/2015 | 06/01/2015 |
| Note: See Notes | |||
| ZON | HOLD | 05/29/2015 | 06/01/2015 |
| Note: Site plan must show setbacks of proposed driveway addition to property lines (including the front). |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 10/30/2015 |
| REINSPECTION FEE | ¤40.00 | 10/30/2015 |
| REINSPECTION FEE | ¤40.00 | 10/30/2015 |
| SITE PLAN 20 | ¤20.00 | 06/25/2015 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/25/2015 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/25/2015 |
| STORM WATER PERMIT FEES | ¤40.00 | 06/25/2015 |
| ADMIN FEE | ¤20.00 | 06/25/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤204.00 |