I want to search for...

Permit #2015060041

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00070-0030
CONDITIONED SPACE: 2022 sqft
GARAGE: 506 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 141 sqft
Total Square Footage: 2869 sqft
Block: 00070
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: (386) 446-5850
Location Address: 131 WOOD HAVEN DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/16/2015
NOC: RECORDED
Applicant name: CHARLES DALLAS RINEK
Owner: RIVERA, WILLIAM & NYDIA

Address

12 RUBY PLACE

NEWARK, NJ 07104

Lot: 0030
Contracted Stated Job Value: ¤276,300.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CHARLES RINEK CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 352502

Palm Coast, FL 32137

CGC046080 (Exp: 08/31/2026) (386) 446-5850 (386)445-9992

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
PAUL S AIELLO
Status Location Address State License Number Phone Fax
CANCEL

PO BOX 351926

PALM COAST, FL 32137

CAC1815808 (Exp: 08/31/2016) (386)239-0053 (386)323-1955
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 03/14/2016 FINAL APPROVED MBACON
BLD - BUILDING FINAL 03/11/2016 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 03/09/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 3/9/2016 3:01:17 PM OUTSIDE OULETS EVEN UNER PORCH NEEDS WATHER PROOF COVER FOR DAMP LOCATION. NEC 406.8.....NEED WORKING OUTSIDE LIGHTS FOR EACH EXTERIOR DOOR.....WATER HAMMMER ARRESTORS SHALL BE INSTALLED TO CONTROL THE FLOW VELOCITY OF THE WATER DISTRIVBUTION SYSTEM......P2903.5. NEED APPROVED FINAL SURVEY ON SITE AT TIME OF INSPECTION,
ROW FINAL 02/23/2016 APPROVED CTROHA
Note: REPAIR 1' X 43' OF DAMAGED ROAD OR PAY $444
FINAL APRON (AFTER POUR/DRIVEWAY) 02/22/2016 APPROVED CTROHA
Note: apron approved
FINAL SURVEY (OFFICE USE ONLY) 02/19/2016 APPROVED JHINDMAN
ELECTRIC - EARLY POWER 01/27/2016 APPROVED JCOLASANTI
Note: Inspection Resulted at 1/27/2016 3:08:10 PM SPOKE TO DALE AT FPL TO RELEASE POWER.
PRE-APRON (PRE-POUR/DRIVEWAY) 01/14/2016 APPROVED - AS NOTED CTROHA
Note: SIDEWALK AT DRIVEWAY CHANGE TO 3' THE REST OF THE SIDEWALK IS CORRECT
GRAVITY SEWER TEST 01/11/2016 APPROVED LMILLER
U - SEWER TIE IN 01/11/2016 APPROVED MBACON
LATH/BRICK/ WATER BARRIER 11/19/2015 APPROVED JCOLASANTI
INSULATION 10/19/2015 APPROVED LMILLER
ALL ROUGH 10/09/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ALL ROUGH 10/07/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 10/7/2015 12:20:26 PM SMOKE DETECTOR GUEST BATH HALL NEEDS TO BE MIN 10`` FROM OPENING. NAIL PLATE IN LAUNDRY ROOM BY DRYER DUCT. DRYER DUCT RESTING ON AC DUCT IN LAUNRY ROOM. SCREW MISSING GARAGE WINDOW.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/01/2015 APPROVED - AS NOTED JCOLASANTI
Note: Inspection Resulted at 9/1/2015 2:59:51 PM TRUSS T06 CALLS FOR TWO STRAPS, ON INSTALLED (CREW ON SITE) WILL CHECK AT ALL ROUGH.
ELECTRIC-TUG 09/01/2015 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 9/1/2015 11:50:46 AM SPOKE TO SUSAN FPL 11:47 RELEASED TUG
TIE BEAM / LINTEL 08/10/2015 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 07/29/2015 APPROVED DREWIS
MONOLITHIC SLAB 07/21/2015 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 07/17/2015 APPROVED JCOLASANTI

Review History

Department Status Date In Date Out
SW1 COMPLETE 02/19/2016 02/19/2016
Note: Released By: JHINDMAN FINAL S
PLUM COMPLETE 09/24/2015 09/28/2015
ZON COMPLETE 09/24/2015 09/28/2015
PLUM HOLD 09/18/2015 09/23/2015
Note: Revision: 1. Gas riser diagram shall show the piping from the source of gas supply up to the appliance being serve. If it is a tank, show its location, size and indicate whether it is under ground or above ground. Also, the riser diagram shall have signature and license number of gas contractor per FBC 5th ed. 107.2.1. F.N. Reodica-386-986-4734.
ZON HOLD 09/18/2015 09/18/2015
Note: Revised site plan must depict location and size of LP tank and must include setbacks to property lines.
SW1 COMPLETE 07/29/2015 07/29/2015
Note: Released By: DREWIS foundation survey
ZON COMPLETE 06/15/2015 06/16/2015
ZON HOLD 06/10/2015 06/11/2015
Note: The copy of the exterior color selections received (although not a very clear copy) does not appear to meet the earth tone requirement of browns, brown-taupe, sandy-taupe, beige, terra cotta, olive, sage or grey. The sample appears to be more in the pink family and therefore would be required to have a LRV of at least 80.
MECH COMPLETE 06/10/2015 06/12/2015
PLUM COMPLETE 06/10/2015 06/12/2015
ELEC COMPLETE 06/10/2015 06/12/2015
ENGIN1 COMPLETE 06/02/2015 06/08/2015
MECH HOLD 06/02/2015 06/05/2015
Note: Energy Performance Level (EPL) Display Card shall be signed by the builder per 2010 FBCEC 405.4.3.
PLUM HOLD 06/02/2015 06/05/2015
Note: Provide sanitary riser diagram with signature and license number of plumbing contractor per 2010 FBC 107.2.1.
SW1 COMPLETE 06/02/2015 06/05/2015
UD1 COMPLETE 06/02/2015 06/03/2015
Note: See Notes
ZON HOLD 06/02/2015 06/03/2015
Note: Unable to verify exterior colors on Sherwin Williams website. Please provide color samples.
URB COMPLETE 06/02/2015 06/02/2015
BLD COMPLETE 06/02/2015 06/05/2015
ELEC HOLD 06/02/2015 06/09/2015
Note: 1.provide a gfci receptacle in the half bath. 2. Provide electrical load calculations 2008 NEC art 220.
ZON HOLD 09/24/2015
Note: Revised site plan must depict location and size of LP tank and must include setbacks to property lines.
PLUM HOLD 09/24/2015
Note: Revision: 1. Gas riser diagram shall show the piping from the source of gas supply up to the appliance being serve. If it is a tank, show its location, size and indicate whether it is under ground or above ground. Also, the riser diagram shall have signature and license number of gas contractor per FBC 5th ed. 107.2.1. F.N. Reodica-386-986-4734.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 03/15/2016
REVISION ¤40.00 02/24/2016
REINSPECTION FEE ¤40.00 02/24/2016
ENGINEERING ROAD DAMAGE ¤444.00 02/23/2016
3% FIRE IMPACT FEE CREDIT (¤6.38) 06/16/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 06/16/2015
IMPACT FEE PARKS ¤849.24 06/16/2015
IMPACT FEE SCHOOL ¤3,600.00 06/16/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 06/16/2015
MECHANICAL FEE ¤226.20 06/16/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/16/2015
PLAN CHECK FEE ¤110.80 06/16/2015
PLUMBING FEE ¤226.20 06/16/2015
SITE PLAN 20 ¤20.00 06/16/2015
SURCHARGE FS 533.721 ¤20.45 06/16/2015
SURCHARGE - FS 468.631 ¤20.45 06/16/2015
STORM WATER PERMIT FEES ¤80.00 06/16/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 06/16/2015
NEW RESIDENTIAL INSPECTIONS ¤554.00 06/16/2015
ADMIN FEE ¤20.00 06/16/2015
ELECTRIC FEE ¤226.20 06/16/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,657.21