Permit Details

Status: COED

Parcel Id: 43-11-31-0000-01010-0010
COMMERCIAL SQUARE FOOTAGE: 1248 sqft
Total Square Footage: 1248 sqft
Subdivision: 2119 - HAMMOCK AT PALM HARBOR
Job Phone: (386) 445-4350
Location Address: 151 CEDAR CV
Type: BC - BUILDING COMMERCIAL
Issue Date: 06/16/2015
NOC: RECORDED
Applicant name: MICHAEL GLEN MACHIN
Owner: THE HAMMOCK AT PALM HARBOR LLC

Address

500 CR, 115 N

BUNNELL, FL 32110

Contracted Stated Job Value: ¤50,000.00
Job Description: 4 CAR GARAGE
Type: CN

Contractor

MACHIN CONSTRUCTION CO
Status Location Address State License Number Phone Fax
INACTIVE

3 HARGROVE GRADE SUITE 1

Palm Coast, FL 32137

CGC058789 (Exp: 08/31/2024) (386) 445-4350 (386)446-5459

Sub Contractors

STEVEN DUANE DENSLOW
Status Location Address State License Number Phone Fax
ACTIVE

317 RIO PINR DR

Ormond Beach, FL 32174

EC0001678 (Exp: 08/31/2026) 386-233-1553 386-673-5994
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 01/07/2016 FINAL APPROVED CMINI
ELECTRIC FINAL 12/21/2015 FINAL APPROVED RMARTIN
Note: THIS IS A REINSPECTION per contractor
ELECTRIC FINAL 12/17/2015 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 12/17/2015 2:33:08 PM NEED REVISION ON NEW PLACEMENT OF SERVICE/METER AS STATED ON PREVIOUS FAILED INSPECTION BY FINAL
FIRE FINAL 12/17/2015 APPROVED JHINDMAN
U - UTILITY COMMERCIAL FINAL 12/17/2015 FINAL APPROVED MBACON
ELECTRIC - EARLY POWER 11/24/2015 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 11/24/2015 10:08:29 AM SPOKE TO DELL FPL RELEASED E.P UNITS1,2,3,4
ELECTRIC 2ND ROUGH 11/18/2015 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 11/18/2015 11:41:20 AM MET CONTRACTOR ON SITE CHECKED TORQUE ON GUTTER, PANELS AND METERS, GOOD FOR EARLY POWER, METERS ARE LABELED UNITS 1,2,3,4, ELECTRICAL SYSTEMS AND DESIGN
ELECTRIC 2ND ROUGH 11/02/2015 Disapproved -FEE REQUIRED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 11/2/2015 1:10:05 PM NEED TO HAVE ELECTRICIAN ON SITE TO CHECK TORQUE ON PANELS/GUTTER NEC 110.14 FPN ALSO CONDUCTORS ARE DAMAGED DUE TO INCORRECT STRIPPING OF INSULATION NEC 110.12 B
FIREWALL 09/23/2015 APPROVED CMINI
ELECTRIC 2ND ROUGH 09/14/2015 PARTIALLY APPROVED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 9/14/2015 10:27:29 AM INTERIOR WALLS AND CEILING OK, STILL NEED TO CKECK CONECTIONS AND TORQUE ON PANELS AND SERVICE WHEN INSTALLED, AND REVISION ON RELOCATING PANELS
ELECTRIC 2ND ROUGH 09/11/2015 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 9/11/2015 10:58:23 AM MISSING STRAPPING ON MC IN TWO LOCATIONS MARKED ON PLAN AND WALLS.....NEC.330.30B ALSO BEFORE FINAL NEED REVISION ON PANEL LOCATIONS, ALSO NEED ALL FEEDER CONDUCTORS AND SERVICE BUILT FOR THIS IS PART OF A SECOND ROUGH INSPECTION, ALL GROUNDS AND NEUTRALS NEED TO BE TERMINATED IN PANELS
FRAMING 09/09/2015 APPROVED - AS NOTED CMINI
Note: Inspection Resulted at 9/9/2015 11:09:27 AM NEED TO BUILD SEPARATION WALLS OUT TO SOFFITS FBC 302. CHECK ON FIREWALL INSPECTION
ROOF SHEATHING / BRACE / TIE DOWN 09/09/2015 APPROVED CMINI
LINTEL 08/28/2015 APPROVED CMINI
FOUNDATION SURVEY - OFFICE USE ONLY 08/27/2015 APPROVED JHINDMAN
MONOLITHIC SLAB 07/29/2015 APPROVED CMINI
ELECTRIC TEMP POLE 07/27/2015 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 7/27/2015 3:12:18 PM SPOKE TO SUSAN FPL RELEASED POWER 3:10
ELECTRIC TEMP POLE 07/22/2015 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 7/22/2015 1:18:28 PM NEED TO CLOSE ALL UNUSED OPENINGS IN TEMP POLE PANEL...NEC 110.12 A

Review History

Department Status Date In Date Out
ELEC COMPLETE 10/14/2015 10/14/2015
SW1 COMPLETE 08/26/2015 08/27/2015
Note: Released By: JHINDMAN foundation survey
BLD COMPLETE 07/14/2015 07/14/2015
DSD COMPLETE 06/16/2015 06/16/2015
BLD COMPLETE 06/16/2015 06/16/2015
ZON COMPLETE 06/16/2015 06/16/2015
DSD HOLD 06/10/2015 06/11/2015
Note: 1. A Subdivision Site Development Permit must be applied for and approved prior to issuance of any accessory permits. 2. Revise the sheet A-2 to state the name of the color and manufacturing company to be used when painting the exterior garage walls.
BLD HOLD 06/02/2015 06/06/2015
Note: 1. Provide UL rating number and UL construction detail for rated tenant separation.
ELEC COMPLETE 06/02/2015 06/05/2015
FI1 COMPLETE 06/02/2015 06/09/2015
MECH COMPLETE 06/02/2015 06/05/2015
Note: na
PLUM COMPLETE 06/02/2015 06/05/2015
Note: na
UD1 COMPLETE 06/02/2015 06/02/2015
ZON HOLD 06/02/2015 06/10/2015
Note: 1. A Subdivision Site Development Permit must be applied for and approved prior to issuance of any accessory permits. 2. Revise the sheet A-2 to state the name of the color and manufacturing company to be used when painting the exterior garage walls.
ENGIN1 COMPLETE 06/02/2015 06/02/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/18/2015
REINSPECTION FEE ¤40.00 12/18/2015
REINSPECTION FEE ¤40.00 12/18/2015
REINSPECTION FEE ¤40.00 12/18/2015
REVISION ¤40.00 12/18/2015
SITE PLAN 20 ¤20.00 06/16/2015
SURCHARGE FS 533.721 ¤12.38 06/16/2015
SURCHARGE - FS 468.631 ¤12.38 06/16/2015
ADMIN COMMERCIAL ¤60.00 06/16/2015
ELECTRIC FEE ¤90.00 06/16/2015
ENGINEERING PERMIT FEES ¤120.00 06/16/2015
3% FIRE IMPACT FEE CREDIT (¤10.10) 06/16/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤336.71 06/16/2015
FIRE PLANS REVIEW ¤25.00 06/16/2015
MECHANICAL FEE ¤90.00 06/16/2015
PERMIT FEE ¤275.00 06/16/2015
PLAN CHECK FEE ¤100.00 06/16/2015
PLUMBING FEE ¤90.00 06/16/2015
Fees Total Due: ¤0.00 Total Paid: ¤1,421.37