I want to search for...

Permit #2015060131

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01150-0060
CONDITIONED SPACE: 2427 sqft
GARAGE: 575 sqft
OPENED PORCH (WITH ROOF) : 180 sqft
OPENED PORCH (WITH ROOF) : 19 sqft
Total Square Footage: 3201 sqft
Block: 01150
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: (904)296-1490
Location Address: 32 LEWIS DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/22/2015
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMPBELL JR
Owner: MARONDA HOMES, INC

Address

9700 PHILIPS HWY

JACKSONVILLE, FL 32256

Address

SUITE 102

JACKSONVILLE, FL 32256

Lot: 0060
Contracted Stated Job Value: ¤114,268.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES INC. OF FLORIDA
Status Location Address State License Number Phone Fax
CANCEL

6800 SOUTHPOINT PKWAY SUITE 300

JACKSONVILLE, FL 32216

CBC058803 (Exp: 08/31/2018) 904-268-7730 904-268-7740

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
ROBERT G DELLO RUSSO
Status Location Address State License Number Phone Fax
DECEASED

531 CODISCO WAY

SANFORD, FL 32771

CAC032448 (Exp: 08/31/2022) (407)831-2665 (407)333-3853
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone Fax
CANCEL

9474 OLD PLANK RD

JACKSONVILLE , FL 32220

CCC1328530 (Exp: 08/31/2016) 904-435-7663 904-404-8406

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/15/2016 FINAL APPROVED MBACON
BLD - BUILDING FINAL 01/14/2016 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 01/04/2016 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 1/4/2016 3:08:16 PM SEPERATION FROM THE RESIDENCE AND ATTICS OF GARAGE MUST BE EQUIVALENT TO 1/2 GYPSUM BOARD, ATTIC STAIRS MUST BE FIRERATED TO 200 FLAME SPREAD INDEX OR PAINTED WITH FIRERATED PAINT. TABLE R302.6.......COULK TOILET COMPLETE IN MASTER BATH.......WATERPROOFING OF OPININGS MASTERBATH SHOWER FIXTURE.. FBC R.2606....LAWN NEEDS TO BE IN PLACE BY RIGHT SIDE OF HOUSE.
FINAL APRON (AFTER POUR/DRIVEWAY) 12/29/2015 APPROVED CTROHA
Note: THIS IS A REINSPECTION COMPLETE
ROW FINAL 12/29/2015 APPROVED - AS NOTED CTROHA
Note: PLACE SOD IN ADJ SWALE SEED AND STRAW ADJ LOT
FINAL APRON (AFTER POUR/DRIVEWAY) 12/28/2015 CANCELLED BY APPLICANT CTROHA
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 12/28/2015 APPROVED DREWIS
FINAL APRON (AFTER POUR/DRIVEWAY) 12/18/2015 Disapproved -FEE REQUIRED CTROHA
Note: no swale detail no survey unable to perform inspection
ELECTRIC - EARLY POWER 12/16/2015 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 12/16/2015 11:00:42 AM SPOKE TO SUSAN FPL RELEASED EARLY POWER 10:55
ELECTRIC - EARLY POWER 12/14/2015 Disapproved -FEE REQUIRED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 12/14/2015 1:18:12 PM INTERIOR PANEL STILL HAS BREAKER/BLANK MISSING NEED TO HAVE COMPLETE BEFORE NEXT INSPECTION, UN USED OPENING .......NEC110.12 A
ELECTRIC - EARLY POWER 12/11/2015 Disapproved -FEE REQUIRED RMARTIN
Note: THIS IS A REINSPECTION Inspection Resulted at 12/11/2015 11:02:08 AM UFER GROUND WAS LOCATED, BUT DOORS WERE LOCKED COULD NOT COMPLETE INSPECTION TO CHECK INTERIOR PANEL BLANK ISSUE, NEED TO HAVE HOME OPEN FOR INSPECTION
ELECTRIC - EARLY POWER 12/10/2015 Disapproved -FEE REQUIRED RMARTIN
Note: Inspection Resulted at 12/10/2015 1:25:28 PM UN-USED OPENING IN PANEL NEED BLANK, COULD NOT LOCATE UFER GROUND
U - SEWER TIE IN 12/04/2015 APPROVED JNICHOLS
PRE-APRON (PRE-POUR/DRIVEWAY) 11/05/2015 APPROVED RGROSS
INSULATION 10/27/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
INSULATION 10/23/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 10/23/2015 11:54:14 AM ACCESS HATCHES AND DOORS FROM CONDITIONED SPACE TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED.BAFFLES RETAINER ARE REQUIRED TO BE PROVIDED WHEN LOOSE FILL INSULATION IS INSTALLED FROM SPILLING INTO LIVING SPACE TO PROVIDE PERMANENT MEANS OF R-VALUE OF LOOSE INSULATION..FBC ENERGY CONSERVATION CODE 402.2.3 (GARAGE CEILING AT CONDITIONED SPACE.)
LATH/BRICK/ WATER BARRIER 10/23/2015 APPROVED JCOLASANTI
ALL ROUGH 10/08/2015 APPROVED - AS NOTED JCOLASANTI
Note: THIS IS A REINSPECTION Inspection Resulted at 10/8/2015 12:08:16 PM TEST ON DWV AND WATER PIPPING FPC .312 FBC 2503.5.1 (WILL CHECK AT INSULATION INSPECTION)
ALL ROUGH 09/30/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 9/30/2015 12:37:48 PM TEST ON DWV AND WATER PIPPING FPC .312 FBC 2503.5.1..NO SLIDER OR FRONT DOOR INSTALLED AT TIME OF INSPECTION. NAIL PLATE WATER LINE GUEST BATH.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/18/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/17/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 9/17/2015 1:44:50 PM CITY APPROVED PLANS NOT ON SITE AT TIME OF INSPECTION.
TIE BEAM / LINTEL 08/27/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 08/25/2015 CANCELLED BY APPLICANT JCOLASANTI
MONOLITHIC SLAB 08/14/2015 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 08/11/2015 APPROVED DREWIS
PLUMBING 1ST ROUGH UNDERGROUND 08/07/2015 APPROVED CMINI
GRAVITY SEWER TEST 08/07/2015 APPROVED CMINI
STEM WALL FOUNDATION 07/28/2015 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
STEM WALL FOUNDATION 07/27/2015 Disapproved -FEE REQUIRED JCOLASANTI
Note: Inspection Resulted at 7/27/2015 2:17:05 PM NEED 20`` GROUND BAR FOR UFER.
STEM WALL FOUNDATION 07/24/2015 CANCELLED BY APPLICANT AIRS WEB

Review History

Department Status Date In Date Out
SW1 COMPLETE 12/22/2015 12/28/2015
Note: Released By: DREWIS
SW1 COMPLETE 08/11/2015 08/11/2015
Note: Released By: DREWIS foundation s
BLD COMPLETE 06/03/2015 06/09/2015
ELEC COMPLETE 06/03/2015 06/09/2015
ENGIN1 COMPLETE 06/03/2015 06/09/2015
MECH COMPLETE 06/03/2015 06/09/2015
PLUM COMPLETE 06/03/2015 06/09/2015
SW1 COMPLETE 06/03/2015 06/09/2015
UD1 COMPLETE 06/03/2015 06/04/2015
Note: See Notes
ZON COMPLETE 06/03/2015 06/04/2015
URB COMPLETE 06/03/2015 06/05/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
REINSPECTION FEE ¤40.00 12/30/2015
ADMIN FEE ¤20.00 06/22/2015
ELECTRIC FEE ¤240.60 06/22/2015
3% FIRE IMPACT FEE CREDIT (¤6.38) 06/22/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 06/22/2015
IMPACT FEE PARKS ¤849.24 06/22/2015
IMPACT FEE SCHOOL ¤3,600.00 06/22/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 06/22/2015
MECHANICAL FEE ¤240.60 06/22/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/22/2015
PLAN CHECK FEE ¤120.40 06/22/2015
PLUMBING FEE ¤240.60 06/22/2015
NEW RESIDENTIAL INSPECTIONS ¤602.00 06/22/2015
SITE PLAN 20 ¤20.00 06/22/2015
SURCHARGE FS 533.721 ¤21.96 06/22/2015
SURCHARGE - FS 468.631 ¤21.96 06/22/2015
STORM WATER PERMIT FEES ¤80.00 06/22/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 06/22/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,557.03