I want to search for...
Permit #2015070389
Permit Details
Status: FINAL
| Parcel Id: 48-11-31-1710-00000-0460 |
| Block: 00000 |
| Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II |
| Job Phone: (386)445-4747 |
| Location Address: 32 SCARLET OAK CIR |
| Type: PO - POOL |
| Issue Date: 08/07/2015 |
| NOC: RECORDED |
| Applicant name: LAWRENCE PATRICK VANDIVIER |
| Owner: SPUDIS STEPHEN D & JACQUELINE H&W |
|
Address 3401 REXFORD CIRCLE ORMOND BEACH, FL 32174 |
| Lot: 0460 |
| Contracted Stated Job Value: ¤27,000.00 |
| Job Description: POOL W/SCREEN ENCLOSURE |
| Type: CN |
Contractor
COUNTRY CLUB POOLS & SPAS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
4444 N. OCEANSHORE BLVD PALM COAST, FL 32137 |
CPC057239 (Exp: 08/31/2024) | (386)445-4747 | (386)445-5955 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
317 RIO PINR DR Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2026) | 386-233-1553 | 386-673-5994 |
BRIAN THOMAS KULL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
18 STRAFORD PLACE PORT ORANGE, FL 32128 |
CGC1504924 (Exp: 08/31/2026) | 386-682-9554 | (386)258-8042 |
GEORGE F AYLSWORTH JR
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
2680 S US HIGHWAY 17 CRESCENT CITY, FL 32112 |
00714 (Exp: 08/31/2021) | 386-698-1033 | 386-698-1077 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 04/06/2016 | FINAL APPROVED | JNICHOLS |
| POOL FINAL | 11/06/2015 | FINAL APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| ROW DAMAGE | 10/30/2015 | APPROVED | GLALIMA |
| POOL FINAL | 10/30/2015 | Disapproved -FEE REQUIRED | CMINI |
| Note: per contractor Inspection Resulted at 10/30/2015 1:39:22 PM .NEED TO HAVE GAUGE ON MOTOR TO CHECK TDH FBC R 4101.20.2 COVERS,FOR HEATED POOLS AND INGROUND PERMANENT INSTALLED SPAS SHALL BE EQUIPTED WITH COVER TO PREVENT HEAT LOSS FBC ENERGY CODE..403.9.3 RELIEF VALVE NEEDED ON SPA HEATER..4101.14.5... NEED TO VENT GAS REGULATER 10`` FROM ANY IGNITION SOURCE. FBC 4101.. CHILD BARRIER FENCE REMOVED, NEEDS TO BE INSTALLED AT ALL TIMES...FBC..4101.17.1.8, COULD NOT LOCATE FINAL APPROVED SURVEY ON SITE | |||
| ELECTRIC AND ALARM | 09/17/2015 | APPROVED | CMINI |
| FINAL SURVEY (OFFICE USE ONLY) | 09/17/2015 | APPROVED | DREWIS |
| POOL DECK | 08/21/2015 | APPROVED - AS NOTED | LMILLER |
| Note: THIS IS A REINSPECTION Inspection Resulted at 8/21/2015 9:32:54 AM STAMPED, APPROVED REVISIONS NOT ON SITE, POUR AT CONTRACTORS RISK!, STAMPED, APPROVED REVISIONS MUST BE ON SITE FOR ANY FUTURE INSPECTIONS. | |||
| POOL DECK | 08/20/2015 | Disapproved -FEE REQUIRED | LMILLER |
| Note: Inspection Resulted at 8/20/2015 3:26:15 PM NEED REVISION ON SPECS SHOWING FOOTING FOR PAIVERS, | |||
| STEEL AND GROUND | 08/11/2015 | APPROVED | DROCKWELL |
| Note: THIS IS A REINSPECTION | |||
| STEEL AND GROUND | 08/10/2015 | Disapproved -FEE REQUIRED | DROCKWELL |
| Note: Inspection Resulted at 8/10/2015 3:02:47 PM SIDEWALL CAVE-IN.NO CLEARANCE FOR STEEL.AT LIGHT AREA |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 09/16/2015 | 09/17/2015 |
| Note: Released By: DREWIS final s | |||
| BLD | COMPLETE | 08/21/2015 | 08/24/2015 |
| BLD | COMPLETE | 08/07/2015 | 08/07/2015 |
| BLD | HOLD | 08/03/2015 | 08/03/2015 |
| Note: Provide the site plan location of u/g gas tank with set back dimensions from building and property as previously requested per . Also, coordinate with residential contractor as another gas riser diagram had been submitted by Amerigas under permit 2014090260 which included pool heater per FBC 5th ed. 107.2.1. F.N Reodica - 386-986-4734. | |||
| BLD | HOLD | 07/15/2015 | 07/15/2015 |
| Note: 1. Provide updated codes for the design criteria of pool and screen enclosure based on FBC 5th edition (2014). 2. Provide gas contractor, gas riser diagram and location of gas tank on site plan with set back dimensions from building and property line for the installation of gas pool heater per FS 489/NFPA 58/FBC 5th ed. 107.2.1. Gas riser diagram shall have signature and license number of gas contractor. | |||
| SW1 | COMPLETE | 07/15/2015 | 07/15/2015 |
| ZON | COMPLETE | 07/15/2015 | 07/16/2015 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 11/06/2015 |
| REINSPECTION FEE | ¤40.00 | 11/06/2015 |
| REVISION | ¤40.00 | 11/06/2015 |
| REINSPECTION FEE | ¤40.00 | 08/11/2015 |
| SITE PLAN 20 | ¤20.00 | 08/07/2015 |
| SURCHARGE FS 533.721 | ¤3.30 | 08/07/2015 |
| SURCHARGE - FS 468.631 | ¤3.30 | 08/07/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/07/2015 |
| ADMIN FEE | ¤20.00 | 08/07/2015 |
| GAS PIPING | ¤40.00 | 08/07/2015 |
| PERMIT FEE | ¤160.00 | 08/07/2015 |
| PLAN CHECK FEE | ¤40.00 | 08/07/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤526.60 |