I want to search for...

Permit #2015070754

Permit Details

Status: COED

Parcel Id: 07-11-31-7006-00050-0220
CONDITIONED SPACE: 2866 sqft
GARAGE: 642 sqft
OPENED PORCH (WITH ROOF) : 135 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 3711 sqft
Block: 00050
Subdivision: 2213 - SECTION 6-FLORIDA PARK
Job Phone: 386-445-9055
Location Address: 3 FLETCHER CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/26/2015
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: CARCICH, ANTHONY P & LISA S

Address

45 CHESTNUT RIDGE RD

HOLANDER, NJ 07733

Lot: 0220
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SUN STATE CUSTOM BUILDERS, LLC
Status Location Address State License Number
CANCEL

946 SHADICH DRIVE

ORANGE CITY, FL

CGC1519145 (Exp: 08/31/2022)

Sub Contractors

CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 08/23/2017 FINAL APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
U -UTILITY RESIDENTIAL FINAL 08/21/2017 Disapproved - NO FEE JNICHOLS
Note: The sewer cleanout cap that is located within the paver driveway needs to be changed to a brass cap
FINAL APRON (AFTER POUR/DRIVEWAY) 08/18/2017 APPROVED RGROSS
Note: APPROVED
ROW FINAL 08/18/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED
ROW FINAL 08/15/2017 Disapproved -FEE REQUIRED CTROHA
Note: NO FINAL SURVEY ON SITE EROSION BY THE SEAWALL SOD ALL BARE GROUND ADJACENT TO THE SEAWALL
BLD - BUILDING FINAL 08/14/2017 FINAL APPROVED CMINI
FINAL SURVEY (OFFICE USE ONLY) 08/11/2017 APPROVED JHINDMAN
PRE-APRON (PRE-POUR/DRIVEWAY) 06/20/2017 APPROVED RGROSS
Note: THIS IS A REINSPECTION. READY FOR PAVERS.
PRE-APRON (PRE-POUR/DRIVEWAY) 06/09/2017 PARTIALLY APPROVED RGROSS
Note: THIS IS A REINSPECTION. APPROVED FOR CONCRETE APRON AND OVER PIPE ONLY. PAVER DRIVEWAY. ON SITE WITH CONTRACTOR EXPLAINING HOW PARTIAL APPROVAL WORKS.
PRE-APRON (PRE-POUR/DRIVEWAY) 06/08/2017 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION. NO SWALE ON SITE. MISSING DOCUMENTATION.
PRE-APRON (PRE-POUR/DRIVEWAY) 06/07/2017 Disapproved - NO FEE RGROSS
Note: HEAVY RAINS BEFORE INSPECTION. CULVERT AND SWALE FLOODED. NO FEE. CONTRACTOR TO RESCHEDULE PRE POUR INSPECTION. 11:55 AM
ELECTRIC - EARLY POWER 05/08/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED EARLY POWER 11:40
GRAVITY SEWER TEST 03/29/2017 APPROVED JGIBSON
U - SEWER TIE IN 03/29/2017 APPROVED JNICHOLS
Note: there was no inspection card on site to sign. this tie in looked good.
ELECTRIC-TUG 02/10/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO SUSAN FPL RELEASED TUG 2:40
INSULATION 12/12/2016 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 12/09/2016 FINAL APPROVED CMINI
ALL ROUGH 12/01/2016 APPROVED CMINI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/01/2016 APPROVED CMINI
TIE BEAM / LINTEL 09/12/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 08/30/2016 Disapproved -FEE REQUIRED LMILLER
Note: OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION (CIRCLED ON FOUNDATION PAGE WITH RED INK). REPAIR EROSION AT BACK PORCH AND OBTAIN ENGINEERS LETTER OF CORRECTION AND APPROVED SOIL TESTS OF COMPLETED REPAIR (FOOTINGS UNDERMINED)
FOUND SURVEY APPROVED (OFFICE) 05/04/2016 APPROVED DREWIS
MONOLITHIC SLAB 03/08/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 3/8/2016 11:09:33 AM SPEC ITEM NUMBER - 10 SHOULD BE 4-NUMBER FIVES EACH WAY.
MONOLITHIC SLAB 03/08/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/02/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 03/01/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 3/1/2016 11:16:09 AM SILT FENCE NEEDS TO BE PROPERLY INSTALLED TO PROTECT ADJASCENT PROPERTY AND WATERWAY. PRESSURE TEST FOR SUPPLLY LINES P2503.7 WATER SUPPLY-SYSTEM TESTING. MUST USE WATER FOR PLASTIC PIPE

Review History

Department Status Date In Date Out
SW1 COMPLETE 08/11/2017 08/11/2017
Note: Released By: JHINDMAN FINAL
ENGIN1 COMPLETE 02/16/2017 02/16/2017
SW1 COMPLETE 02/16/2017 02/16/2017
UD1 COMPLETE 02/16/2017 02/20/2017
Note: This is a Gravity sewer, the Sewer Tie-in Inspection is a visual inspection it must be called in the day before the tie-in is to be made. The morning of the tie-in the inspector should be contacted to coordinate the time of the tie-in so he can witness the tie-in and help prevent failed inspections due to cave in or mud/water preventing the visual inspection. All new Concrete work including Driveway Pavers must maintain at least a 4.5 feet clear zone from all Water / Reuse Meter Pits or Pep Tank lids and 9 feet behind the pep tank lids. All sewer cleanouts or valves located within the concrete area must be raised flush with the grade and sewer cleanouts must have a flush brass cap.
ZON COMPLETE 02/16/2017 02/16/2017
SW1 COMPLETE 05/03/2016 05/04/2016
Note: Released By: DREWIS Foundation survey
ZON COMPLETE 10/05/2015 10/06/2015
ELEC COMPLETE 09/25/2015 09/25/2015
PLUM COMPLETE 09/25/2015 09/28/2015
BLD COMPLETE 09/25/2015 09/28/2015
URB COMPLETE 09/25/2015 09/25/2015
ZON HOLD 09/25/2015 09/28/2015
Note: REPEAT COMMENT: Right of Way Utilization Agreement for paver driveway is required. Please note that this Agreement must be signed by all persons on property deed, witnessed and notarized. If driveway material is changed, the site plan must be corrected to indicate the change.
BLD HOLD 07/28/2015 07/28/2015
Note: 1. Provide plans that are designed to the 5th edition (2014) of the Florida building code.
ELEC HOLD 07/28/2015 07/28/2015
Note: 1. Provide plans that are designed to the 2011 NEC. 2. Provide electrical load calculation per 2011 NEC art 220.
ENGIN1 COMPLETE 07/28/2015 07/31/2015
MECH COMPLETE 07/28/2015 07/28/2015
PLUM HOLD 07/28/2015 07/28/2015
Note: Sanitary riser diagram shows summer kitchen sink drain tied into a shower fixture drain of pool bathroom which does not comply with FBCR 5th edition P3108.1.
SW1 COMPLETE 07/28/2015 07/28/2015
UD1 COMPLETE 07/28/2015 07/29/2015
Note: See Notes
ZON HOLD 07/28/2015 07/29/2015
Note: 1. Provide landscape plan. 2. Right of Way Utilization Agreement for paver driveway is required. Please note that this Agreement must be signed by all persons on property deed, witnessed and notarized.
URB HOLD 07/28/2015 07/29/2015
Note: Need landscape plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 08/23/2017
CONTRACTOR CHANGE ¤40.00 08/23/2017
REINSPECTION FEE ¤40.00 08/23/2017
REINSPECTION FEE ¤40.00 08/23/2017
REINSPECTION FEE ¤40.00 08/23/2017
REINSPECTION FEE ¤40.00 08/23/2017
REINSPECTION FEE ¤40.00 08/23/2017
NEW RESIDENTIAL INSPECTIONS ¤704.00 10/26/2015
SITE PLAN 20 ¤20.00 10/26/2015
SURCHARGE FS 533.721 ¤25.18 10/26/2015
SURCHARGE - FS 468.631 ¤25.18 10/26/2015
STORM WATER PERMIT FEES ¤80.00 10/26/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 10/26/2015
ELECTRIC FEE ¤271.20 10/26/2015
3% FIRE IMPACT FEE CREDIT (¤6.38) 10/26/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 10/26/2015
IMPACT FEE PARKS ¤849.24 10/26/2015
IMPACT FEE SCHOOL ¤3,600.00 10/26/2015
RECORDING FEE REIMBURSE DOC ¤52.50 10/26/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 10/26/2015
MECHANICAL FEE ¤271.20 10/26/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 10/26/2015
PLAN CHECK FEE ¤140.80 10/26/2015
PLUMBING FEE ¤271.20 10/26/2015
ADMIN FEE ¤20.00 10/26/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,750.17