I want to search for...
Permit #2015080155
Permit Details
Status: COED
| Parcel Id: 07-11-31-7012-00100-0500 |
| CONDITIONED SPACE: 529 sqft |
| Total Square Footage: 529 sqft |
| Block: 00100 |
| Subdivision: 2187 - SECTION 12-BELLE TERRE |
| Job Phone: (386) 445-4350 |
| Location Address: 128 BARRINGTON DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 08/25/2015 |
| NOC: RECORDED |
| Applicant name: MICHAEL GLEN MACHIN |
| Owner: CAPUA, BENJAMIN R & CONSTANCE |
|
Address 128 BARRINGTON DR PALM COAST, FL 32137 |
| Lot: 0500 |
| Contracted Stated Job Value: ¤50,000.00 |
| Job Description: BEDROOM & BATH ADDITION |
| Type: CN |
Contractor
MACHIN CONSTRUCTION CO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3 HARGROVE GRADE SUITE 1 Palm Coast, FL 32137 |
CGC058789 (Exp: 08/31/2024) | (386) 445-4350 | (386)446-5459 |
Sub Contractors
STEVEN DUANE DENSLOW
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
317 RIO PINR DR Ormond Beach, FL 32174 |
EC0001678 (Exp: 08/31/2026) | 386-233-1553 | 386-673-5994 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2 HARGROVE GRADE PALM COAST, FL 32136 |
CAC048127 (Exp: 08/31/2018) | 386-445-5023 | 386-446-4614 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
JOANNA S REELEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
2 MARKET PLACE D PALM COAST, FL 32137 |
CCC1327485 (Exp: 08/31/2020) | 386-445-7945 |
DAVID R ROWE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
45 SOUTH DIXIE HIGHWAY ST. AUGUSTINE, FL 32084 |
01593 (Exp: 08/08/2022) | 904-824-2605 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 02/16/2016 | FINAL APPROVED | MBACON |
| BLD - BUILDING FINAL | 02/15/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/11/2016 | APPROVED | DREWIS |
| GAS FINAL | 02/09/2016 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| BLD - BUILDING FINAL | 02/09/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 2/9/2016 1:50:08 PM NEED APPROVED FINAL SURVEY ON SITE AT TIME OF INSPECTION...SOFFIT NEEDS TO BE UNVENTED SOLID 3`` ON BOTH SIDES OF EXHAUST VENTS PER ENERGY CODE. | |||
| BLD - BUILDING FINAL | 01/28/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 1/28/2016 2:56:42 PM FINAL GRADE AND SOD MUST BE PLACED FOR FINAL INSPECTION. REMOVE JON BOY FOR FINAL INSPECTION. | |||
| GAS FINAL | 01/28/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/28/2016 2:56:42 PM GAS LINES NEED TO BE ATTACHED FOR FINAL INSPECTION. | |||
| GAS ROUGH | 01/28/2016 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| GAS FINAL | 01/21/2016 | Disapproved - NO FEE | JCOLASANTI |
| Note: Inspection Resulted at 1/21/2016 11:27:06 AM SEE ROUGH COMMENTS AND (NEED TO SEE SHUT OFF VALVE.SHUT OFF VALVE) SHALL BE LOCATED WITHIN 6’ OF APPLIANCE IN SAME RM FBC.G. 2420.5.1 | |||
| GAS ROUGH | 01/21/2016 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: THIS IS A REINSPECTION Inspection Resulted at 1/21/2016 11:27:05 AM TEST PRESSURE NEEDED ON PIPE END OF PIPE FBC.G2417.3.3 (NEED TO HAVE GAGE AT END OF LINE BY TANK | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/06/2016 | APPROVED | DREWIS |
| Note: THIS IS A REINSPECTION | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/04/2016 | Disapproved - NO FEE | DREWIS |
| Note: Please provide survey measurements within the drainage easement to assure positive storm water flow. -DC. Rewis 986-4736 | |||
| INSULATION | 11/30/2015 | APPROVED | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 11/23/2015 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ALL ROUGH | 11/20/2015 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 11/20/2015 2:44:41 PM FIREBLOCK CHASE BY REAR WINDOW, INSTALL NAIL PLATES AND REVISE PLAN TO SHOW ADDED LIGHTS AND OUTET. | |||
| GAS ROUGH | 11/20/2015 | CANCELLED BY APPLICANT | JCOLASANTI |
| LATH/BRICK/ WATER BARRIER | 11/20/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 11/20/2015 2:44:42 PM NEED TO INSTALL EXPANSION JOINT ON EXTERIOR SOLID WALL SPACE OVER 144SQ FT. | |||
| WALL SHEATHING | 11/02/2015 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| WALL SHEATHING | 10/29/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 10/29/2015 11:52:17 AM NEED TO FOLLOW NAIL PATTERN PER PLAN. MISSING NAILS AND SOME NAILS IN TO DEEP. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/29/2015 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/28/2015 | Disapproved -FEE REQUIRED | JCOLASANTI |
| Note: Inspection Resulted at 10/28/2015 2:05:32 PM NEED APPROVED TRUSS ENGINEERING ON SITE AT TIME OF INSPECTION. CALL IN WALL SHEETING INSPECTION WHEN READY. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/20/2015 | APPROVED | DREWIS |
| MONOLITHIC SLAB | 09/24/2015 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/18/2015 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Inspection Resulted at 9/18/2015 10:09:41 AM INSPECTED DWV SYSTEM ONLY, WATER LINES NOT INSTALLED FOR THIS INSPECTION. |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 02/11/2016 | 02/11/2016 |
| Note: Released By: DREWIS final s | |||
| MECH | COMPLETE | 01/22/2016 | 01/25/2016 |
| Note: Revision - Duct leakage test certification. | |||
| SW1 | COMPLETE | 01/06/2016 | 01/06/2016 |
| Note: Released By: DREWIS | |||
| SW1 | HOLD | 01/04/2016 | 01/04/2016 |
| Note: Please provide survey measurements within the drainage easement to assure positive storm water flow. -DC. Rewis 986-4736 | |||
| ELEC | COMPLETE | 12/02/2015 | 12/02/2015 |
| PLUM | COMPLETE | 11/13/2015 | 11/16/2015 |
| Note: Revision: Added 60 gal A/G propane gas tank and piping to fireplace. | |||
| ZON | COMPLETE | 11/13/2015 | 11/13/2015 |
| BLD | COMPLETE | 10/22/2015 | 10/22/2015 |
| SW1 | COMPLETE | 10/19/2015 | 10/20/2015 |
| Note: Released By: DREWIS foundation s | |||
| BLD | COMPLETE | 08/24/2015 | 08/24/2015 |
| ELEC | COMPLETE | 08/19/2015 | 08/21/2015 |
| PLUM | COMPLETE | 08/19/2015 | 08/20/2015 |
| BLD | HOLD | 08/19/2015 | 08/20/2015 |
| Note: Provide manufacturer's specification and installation instructions of spray foam insulation as previously requested per FBC 5th ed. 107.2.1 F.N. Reodica - 386-986-4734. | |||
| ZON | COMPLETE | 08/19/2015 | 08/20/2015 |
| BLD | HOLD | 08/07/2015 | 08/07/2015 |
| Note: Clarify if the attic is vented or unvented as energy calculation shows unvented but plan/detail shows vented. Also, coordinate the insulation values for wall and ceiling per FBC 5th ed. 107.2.1. If unvented, provide type of insulation and manufacturer's specification and installation instructions. F.N. Reodica - 386-986-4734. | |||
| SW1 | COMPLETE | 08/07/2015 | 08/07/2015 |
| ZON | HOLD | 08/07/2015 | 08/10/2015 |
| Note: 1. Provide landscape plan. 2. Provide site plan on 8 1/2" x 11" or 8 1/2" x 14" paper. 3. Provide statement that colors and materials depicted on color and material sheet match the existing colors and materials of the house. 4. Due to size of addition, please provide pervious vs. impervious calculation of the lot. | |||
| ELEC | HOLD | 08/07/2015 | 08/07/2015 |
| Note: 1. Provide a disconnect for the air handler. 2011 NEC art 440. 2. The current design code is the 2011 NEC please revise. J. Hindman 986-3784. | |||
| MECH | COMPLETE | 08/07/2015 | 08/07/2015 |
| PLUM | HOLD | 08/07/2015 | 08/07/2015 |
| Note: Provide sanitary riser diagram either prepared by design professional or plumbing contractor with signature and license number per FBC 5th ed. 107.2.1. FN. Reodica -386-986-4734. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/11/2016 |
| REINSPECTION FEE | ¤40.00 | 02/11/2016 |
| REINSPECTION FEE | ¤40.00 | 01/27/2016 |
| REVISION | ¤40.00 | 01/27/2016 |
| REVISION | ¤40.00 | 01/20/2016 |
| REVISION | ¤40.00 | 01/20/2016 |
| REVISION | ¤40.00 | 01/20/2016 |
| REINSPECTION FEE | ¤40.00 | 01/20/2016 |
| REINSPECTION FEE | ¤40.00 | 01/20/2016 |
| REINSPECTION FEE | ¤40.00 | 01/20/2016 |
| CONTRACTOR CHANGE | ¤40.00 | 01/20/2016 |
| ELECTRIC FEE | ¤95.40 | 08/25/2015 |
| MECHANICAL FEE | ¤95.40 | 08/25/2015 |
| PLAN CHECK FEE | ¤40.00 | 08/25/2015 |
| PLUMBING FEE | ¤95.40 | 08/25/2015 |
| ADMIN FEE | ¤20.00 | 08/25/2015 |
| SITE PLAN 20 | ¤20.00 | 08/25/2015 |
| SURCHARGE FS 533.721 | ¤5.79 | 08/25/2015 |
| SURCHARGE - FS 468.631 | ¤5.79 | 08/25/2015 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/25/2015 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 08/25/2015 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤937.78 |