I want to search for...

Permit #2015080711

Permit Details

Status: COED

Parcel Id: 15-11-31-1950-00000-0350
CONDITIONED SPACE: 1996 sqft
GARAGE: 456 sqft
OPENED PORCH (WITH ROOF) : 146 sqft
OPENED PORCH (WITH ROOF) : 25 sqft
Total Square Footage: 2623 sqft
Block: 00000
Subdivision: 1062 - FAIRWAYS EDGE AT GRAND HAVEN
Job Phone: 386-236-4133
Location Address: 14 AUGUSTA TRL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/21/2015
NOC: RECORDED
Applicant name: KEVIN MICHAEL MAYS
Owner: INTERVEST CONSTRUCTION INC

Address

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

Lot: 0350
Contracted Stated Job Value: ¤246,511.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INTERVEST CONSTRUCTION, INC
Status Location Address State License Number Phone Fax
CANCEL

2379 BEVILLE ROAD

DAYTONA BEACH, FL 32119

CGC1517573 (Exp: 08/31/2018) 386-236-4133 386-763-7833

Sub Contractors

STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472
CHRIS C KOONTZ
Status Location Address State License Number Phone Fax
INACTIVE

651 CARSWELL AVE

Holly Hill, FL 32117

CAC035563 (Exp: 08/31/2024) (386) 252-1878 (386)252-9703
GARY WAYNE EVERS
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 740106

ORANGE CITY, FL 32763

CFC050566 (Exp: 08/31/2026) 386-775-0909 386-775-0918
BARRY D MARTIN
Status Location Address State License Number Phone Fax
CANCEL

1650 N STATE STREET

Bunnell, FL 32110

CCC033728 (Exp: 08/31/2020) (386) 437-7700 (386)437-7701

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/20/2016 FINAL APPROVED DSPENCER
BLD - BUILDING FINAL 01/19/2016 FINAL APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROW FINAL 01/19/2016 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
ROW FINAL 01/15/2016 CANCELLED BY APPLICANT GLALIMA
BLD - BUILDING FINAL 01/15/2016 Disapproved -FEE REQUIRED DROCKWELL
Note: per contractor Inspection Resulted at 1/15/2016 2:09:55 PM GFI RECEPT IN KITCHEN WILL NOT RE-SET/PULL DOWN STAIRS COVER MUST BE RATED/DOOR FROM GARAGE TO HOUSE MUST SELF-CLOSE AND LATCH FBC-ENERGY
FINAL SURVEY (OFFICE USE ONLY) 01/11/2016 APPROVED DREWIS
Note: THIS IS A REINSPECTION
FINAL SURVEY (OFFICE USE ONLY) 01/04/2016 Disapproved - NO FEE DREWIS
Note: Please provide survey measurements within the east side easement. -DC. Rewis 986-4736
FINAL APRON (AFTER POUR/DRIVEWAY) 01/04/2016 FINAL APPROVED GLALIMA
Note: THIS IS A REINSPECTION
FINAL APRON (AFTER POUR/DRIVEWAY) 12/31/2015 CANCELLED BY APPLICANT GLALIMA
ELECTRIC - EARLY POWER 12/29/2015 APPROVED - AS NOTED RMARTIN
Note: Inspection Resulted at 12/29/2015 2:45:05 PM SPOKE TO DELL FPL RELEASED EARLY POWER 2:42
PRE-APRON (PRE-POUR/DRIVEWAY) 12/03/2015 APPROVED CTROHA
LATH/BRICK/ WATER BARRIER 11/20/2015 APPROVED DROCKWELL
INSULATION 11/13/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
INSULATION 11/12/2015 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 11/12/2015 1:57:05 PM NEED TO REMOVE MOST OF DRYWALL ON CEILINGS AND WALLS, CANNOT SEE ALL BEAVE BAFFLES FBC. ENERGY402.2.3.. MISSING BLOWN IN MARKERS FOR R-30 FBC ENERGY 303.1.1.2.1.. NEED TO REMOVE WHITE FOAM AND INSTALL FIRE FOAM AT PLUMBING PIPES..FBC 302.. MISSING FIREFOAMM AT ANNULAR SPACES, CHECK ALL. FBC 302
U - SEWER TIE IN 11/12/2015 APPROVED JNICHOLS
GRAVITY SEWER TEST 11/12/2015 APPROVED CMINI
INSULATION 11/10/2015 CANCELLED BY APPLICANT LMILLER
Note: THIS IS A REINSPECTION
INSULATION 11/09/2015 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 11/9/2015 9:50:59 AM NOT READY
ALL ROUGH 11/06/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ALL ROUGH 11/05/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 11/5/2015 2:25:07 PM PRESSURIZE SUPPLY LINES
ALL ROUGH 11/04/2015 CANCELLED BY APPLICANT DROCKWELL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/03/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/02/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: THIS IS A REINSPECTION Inspection Resulted at 11/2/2015 2:09:28 PM NO PLANS ON SITE/2 TRUSSES OVER SLIDER NOT STRAPPED/MISSINH H2 CLIP AT BEARING WALL TRUSS/INCOMPLETE INSPECTION
WALL SHEATHING 11/02/2015 APPROVED DROCKWELL
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/30/2015 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 10/30/2015 11:58:03 AM MISSING STRAPS PER PLAN H2.5 ON EACH SIDE OF BEARING WALL...MISSING HTT4 AT BASE WITH 2PLY 2X6, MISSING NAILS IN TRUSS STAP B5..NEED CORRECTIONS ON DETAILS CIRCLED ON ROOF PLAN. ALSO ANCHOR BOLTS LOOSE AT GARAGE ENTRY DOOR.. NOT READY
WALL SHEATHING 10/30/2015 Disapproved - NO FEE CMINI
Note: Inspection Resulted at 10/30/2015 11:58:04 AM WALL SHEATHING COVERED UP
ELECTRIC-TUG 10/16/2015 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 10/15/2015 APPROVED LMILLER
ELECTRIC-TUG 10/15/2015 CANCELLED BY APPLICANT RMARTIN
FOUND SURVEY APPROVED (OFFICE) 10/14/2015 APPROVED DREWIS
MONOLITHIC SLAB 10/02/2015 APPROVED DROCKWELL
PLUMBING 1ST ROUGH UNDERGROUND 09/30/2015 APPROVED LMILLER
Note: THIS IS A REINSPECTION
PLUMBING 1ST ROUGH UNDERGROUND 09/29/2015 Disapproved -FEE REQUIRED DROCKWELL
Note: Inspection Resulted at 9/29/2015 1:47:04 PM HOT WATER LINES MUST BE INSULATED PER FBC-ENERGY 403.4.2/AIR CANNOT BE USED AS TEST ON SANITARY LINES PER FBC-PLUMBING 312.3

Review History

Department Status Date In Date Out
SW1 COMPLETE 01/08/2016 01/11/2016
Note: Released By: DREWIS
SW1 HOLD 01/04/2016 01/04/2016
Note: Held By: DREWIS Please show elevation measurements within the east side drainage easement or residence. -DC. Rewis 986-4736
SW1 COMPLETE 10/13/2015 10/14/2015
Note: Released By: DREWIS foundation s
BLD COMPLETE 09/15/2015 09/17/2015
ZON COMPLETE 09/10/2015 09/11/2015
BLD HOLD 09/10/2015 09/10/2015
Note: 1. Attic ventilation shall comply with FBCR 5th ed. R 806.2. 2nd request. The calculation on sheet A3 must be changed to show that it meets the new code requirements. j. Hindman 986-3784.
ELEC COMPLETE 09/10/2015 09/10/2015
ENGIN1 COMPLETE 09/10/2015 09/15/2015
SW1 COMPLETE 09/10/2015 09/10/2015
BLD HOLD 08/27/2015 08/28/2015
Note: Attic ventilation shall comply with FBCR 5th ed. R 806.2.
ELEC HOLD 08/27/2015 08/31/2015
Note: 1. Provide the correct code reference on the electrical sheet per 2011 National Electric code. 2. Identify the electrical panel location and provide a disconnect at the water heater if the panel is not located in the garage. 2011 NEC art 422. J. Hindman 986-3784.
ENGIN1 COMPLETE 08/27/2015 08/27/2015
Note: No swale plan required.
MECH COMPLETE 08/27/2015 08/27/2015
PLUM COMPLETE 08/27/2015 08/27/2015
SW1 COMPLETE 08/27/2015 08/31/2015
UD1 COMPLETE 08/27/2015 08/28/2015
Note: See Notes
ZON HOLD 08/27/2015 08/28/2015
Note: 1. Site plan has incorrect platted easement information depicted. 2. On site plan, provide dimensions and setbacks of AC pad to demonstrate that it is not encroaching the 10' easement on right side of property. T. Childs
URB COMPLETE 08/27/2015 08/27/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 01/21/2016
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 01/07/2016
REINSPECTION FEE ¤40.00 01/07/2016
NEW RESIDENTIAL INSPECTIONS ¤494.00 09/21/2015
SITE PLAN 20 ¤20.00 09/21/2015
SURCHARGE FS 533.721 ¤18.56 09/21/2015
SURCHARGE - FS 468.631 ¤18.56 09/21/2015
STORM WATER PERMIT FEES ¤80.00 09/21/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 09/21/2015
ADMIN FEE ¤20.00 09/21/2015
ELECTRIC FEE ¤208.20 09/21/2015
3% FIRE IMPACT FEE CREDIT (¤6.38) 09/21/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 09/21/2015
IMPACT FEE PARKS ¤849.24 09/21/2015
IMPACT FEE SCHOOL ¤3,600.00 09/21/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 09/21/2015
MECHANICAL FEE ¤208.20 09/21/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 09/21/2015
PLAN CHECK FEE ¤98.80 09/21/2015
PLUMBING FEE ¤208.20 09/21/2015
Fees Total Due: ¤0.00 Total Paid: ¤9,243.43