I want to search for...

Permit #2015090296

Permit Details

Status: COED

Parcel Id: 05-11-31-5918-00000-0110
CONDITIONED SPACE: 3709 sqft
GARAGE: 934 sqft
OPENED PORCH (WITH ROOF) : 630 sqft
OPENED PORCH (WITH ROOF) : 488 sqft
OPENED PORCH (WITH ROOF) : 200 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
Total Square Footage: 6061 sqft
Block: 00000
Subdivision: 2244 - VILLAGE AT PALM COAST PH 1
Job Phone: (386) 445-7001
Location Address: 18 LONGVIEW WAY N
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/02/2015
NOC: RECORDED
Applicant name: RICHARD M. ANDERSON
Owner: ANDERSON THOMAS R

Address

18 LONGVIEW WAY NORTH

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

PALM WEST HOME BUILDERS, INC.
Status Location Address State License Number Phone Fax
ACTIVE

2 Florida Park Drive North

Palm Coast, FL 32137

CRC054633 (Exp: 08/31/2026) (386) 445-7001 (386)446-5941

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone Fax
CANCEL

2 HARGROVE GRADE

PALM COAST, FL 32136

CAC048127 (Exp: 08/31/2018) 386-445-5023 386-446-4614
THOMAS WALTER ALBANO
Status Location Address State License Number Phone Fax
INACTIVE

P. O. BOX 352075

Palm Coast, FL 32135

CFC045991 (Exp: 08/31/2024) 386-437-2795 (386)437-2781
JOANNA S REELEY
Status Location Address State License Number Phone
INACTIVE

2 MARKET PLACE D

PALM COAST, FL 32137

CCC1327485 (Exp: 08/31/2020) 386-445-7945

Inspection History

Type Request Date Result Inspector
FINAL APRON (AFTER POUR/DRIVEWAY) 06/28/2017 APPROVED CTROHA
Note: MEETS REQUIREMENTS AT TIME OF THE INSPECTION
ROW FINAL 06/28/2017 APPROVED - AS NOTED CTROHA
Note: SEED AND STRAW DOWN BOTH SIDES OF THE PROPERTY ALL BARE GROUND ON ADJACENT LOTS PICK UP ALL TRASH ON ADJACENT LOTS THIS WILL BE DONE BY 2:30 ON 6/29/2017 THIS IS AN EXCEPTION SO THAT THE CLOSING IS NOT HELD UP
U -UTILITY RESIDENTIAL FINAL 06/28/2017 FINAL APPROVED JNICHOLS
BLD - BUILDING FINAL 06/27/2017 FINAL APPROVED CMINI
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 06/23/2017 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION. DISCONNECT BEHIND CONDENSING UNIT NEEDS TO HAVE A WORKING CLEARANCE OF 36" PER NEC 110.26 A1..OPENINGS AND PENETRATIONS THROUGH WALLS OR CEILINGS SEPARATING THE DWELLING UNIT FROM THE GARAGE SHALL NOT BE PERMITTED fbc. R302.5.. Required outlets and spacing of outlets. NEC 2008 210.52 in kitchen. need to close electric boses under stove. label breaker in meter panel.. remove debris from both sides of adjacent lots
BLD - BUILDING FINAL 06/22/2017 Disapproved -FEE REQUIRED CMINI
Note: not ready
FINAL SURVEY (OFFICE USE ONLY) 06/19/2017 APPROVED JHINDMAN
PLUMBING 1ST ROUGH UNDERGROUND 05/30/2017 APPROVED - AS NOTED JGIBSON
Note: THIS WAS AN INSPECTION FOR A REVISION IN DOWNSTAIRS LEFT BATHROOM CHANGING A SHOWER TO A TUB
U - SEWER TIE IN 04/21/2017 APPROVED JNICHOLS
Note: THIS IS A REINSPECTION
GRAVITY SEWER TEST 04/20/2017 APPROVED - AS NOTED JGIBSON
Note: THIS INSPECTION WAS ALREADY APPROVED ON MARCH 13 BY LEE MILLER
U - SEWER TIE IN 03/31/2017 PARTIALLY APPROVED JNICHOLS
PRE-APRON (PRE-POUR/DRIVEWAY) 03/31/2017 APPROVED CTROHA
Note: READY TO POUR It is the BUILDER'S RESPONSIBILITY: to form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
GRAVITY SEWER TEST 03/13/2017 APPROVED LMILLER
ELECTRIC - EARLY POWER 01/18/2017 APPROVED - AS NOTED RMARTIN
Note: SPOKE TO DELL FPL RELEASED EARLY POWER 2:20
INSULATION 08/18/2016 APPROVED CMINI
LATH/BRICK/ WATER BARRIER 07/26/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
LATH/BRICK/ WATER BARRIER 07/25/2016 CANCELLED BY APPLICANT CMINI
Note: THIS IS A REINSPECTION. Richie from Palm West called to cancel
ALL ROUGH 06/07/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
ALL ROUGH 05/17/2016 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION Inspection Resulted at 5/17/2016 1:32:44 PM UNGROUNDED CONDUCTORS USED AS HOT SHALL BE PHASED OUT..210.5(C).... UNDERGROUND WIRE INSTALLATIONS... FBC 3803,10 WET LOCATIONS, UNDERGROUND CONDUCTORS MUST LISTED FOR USE IN WET LOCATIONS... NAIL PLATES M1308.2 PROTECTION FROM PHYSICAL DAMAGE… IF PIPE IS LESS THAN 1.5” FROM EDGE IT MUST BE PROTECTED WITH A MINIMUM OF 16 GAGE STEEL PLATE AND PLATE MUST EXTEND A MINIMUM OF 2” ABOVE THE SOLE PLATES AND BELOW THE TOP PLATES... NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. AND SHALL EXTEND NO LESS THAN 2 INCHES ABOVE SOLE PLATES AND BELOW TOP PLATES... NAIL PLATES ON ELECTRIC FBC E3802.1 THROUGHOUT.... 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG ADGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 INCHES AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE.... NEED TO OBTAIN A REVISION FOR MECHANICAL (NOT AS SHOWN IN APPROVED DOCUMENTS)... GROUNDING INSULATORS MUST BE GREEN, FBC E 3407
WINDOW NAILING 04/27/2016 APPROVED CMINI
ALL ROUGH 04/22/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 4/22/2016 2:53:12 PM NOT READY, INCOMPLETE INSPECTION! (WINDOW NAILING,, PLUMBING, ELECTRICAL. (NOTHING READY)
LATH/BRICK/ WATER BARRIER 04/07/2016 Disapproved - NO FEE CMINI
Note: only small gables at front top ready, partial. need to call in when rest is ready
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/29/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2016 Disapproved -FEE REQUIRED CMINI
Note: THIS IS A REINSPECTION Inspection Resulted at 3/21/2016 3:11:57 PM NEED REVISIONS OR CORRECT IN FIELD, TRUSS CONNECTIONS PER PLAN, PLAN CALLING FOR MTS20S- MTS16 INSTALLED, 3-2X12 HEADER VERSES 2- 2X12 INSTALLED, CONTINUOUS LOAD PATH ON 2ND FL PORCH HEADER USING H2.5S ON 2X4 NOT ATTACHED TO HEADER,FLOOR TRUSSES NOT MATCHING PAPER WORK. NEED TO FINISH WALL SHEATHING,
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/18/2016 CANCELLED BY APPLICANT LMILLER
ELECTRIC-TUG 02/22/2016 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION ok per Robert Inspection Resulted at 2/22/2016 1:50:12 PM SPOKE TO SUSAN FPL RELEASED TUG 1:49
ELECTRIC-TUG 02/12/2016 Disapproved - NO FEE RMARTIN
Note: Inspection Resulted at 2/12/2016 1:20:57 PM NEED REVISION ON SITE FOR INSPECTION,SHOWING CHANGES OF SERVICE SIZE AND CONDUIT
TIE BEAM / LINTEL 01/25/2016 APPROVED LMILLER
Note: THIS IS A REINSPECTION
TIE BEAM / LINTEL 01/22/2016 Disapproved -FEE REQUIRED LMILLER
Note: Inspection Resulted at 1/22/2016 11:30:47 AM VERTICAL REBAR NEEDS TO HAVE ½” FOR MAXIMUM COVER..FBC606.9.4 OVERBEND DOWEL BAR FBC R606.13.3 EXCEPTION….. WITH A VERTICAL CELL NOT MORE THAN 1” OF HORIZONTAL DISPLACEMENT TO 6” OF VERTICAL BAR LENGTH. (MARKED ON FOUNDATION PLAN)
FOUND SURVEY APPROVED (OFFICE) 01/21/2016 APPROVED JHINDMAN
MONOLITHIC SLAB 01/07/2016 APPROVED CMINI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 01/06/2016 Disapproved -FEE REQUIRED CMINI
Note: Inspection Resulted at 1/6/2016 9:58:39 AM NOT READY, JOB NEEDS TO BE READY WHEN CALLED IN. F.B.C. 105.1
PLUMBING 1ST ROUGH UNDERGROUND 12/29/2015 APPROVED CMINI
STEM WALL FOUNDATION 12/17/2015 APPROVED LMILLER
STEM WALL FOUNDATION 12/07/2015 APPROVED CMINI

Review History

Department Status Date In Date Out
SW1 COMPLETE 06/16/2017 06/19/2017
Note: Released By: JHINDMAN final s
PLUM COMPLETE 05/09/2017 05/10/2017
Note: Revision: chaged first floor suite-1 bathroom shower to tub.
MECH COMPLETE 05/25/2016 05/27/2016
Note: revision- changed duct layout at the second floor.
BLD COMPLETE 05/11/2016 05/12/2016
ELEC COMPLETE 05/11/2016 05/12/2016
BLD COMPLETE 03/23/2016 03/28/2016
ELEC COMPLETE 02/16/2016 02/18/2016
SW1 COMPLETE 01/20/2016 01/21/2016
Note: Released By: JHINDMAN foundation s
BLD COMPLETE 12/09/2015 12/15/2015
ELEC COMPLETE 09/23/2015 09/24/2015
ZON COMPLETE 09/23/2015 09/24/2015
PLUM COMPLETE 09/23/2015 09/24/2015
BLD COMPLETE 09/23/2015 09/24/2015
BLD HOLD 09/14/2015 09/15/2015
Note: 1. Provide the roof truss layout from the truss engineer. 5th ed. FBC 107.2.1.
ELEC HOLD 09/14/2015 09/14/2015
Note: Please update to current National Electric Code. -DC. Rewis 9864736
ENGIN1 COMPLETE 09/14/2015 09/16/2015
MECH COMPLETE 09/14/2015 09/15/2015
PLUM HOLD 09/14/2015 09/15/2015
Note: 1. Provide second floor plumbing riser. 5th ed FBC 107.2.1.
SW1 COMPLETE 09/14/2015 09/14/2015
UD1 COMPLETE 09/14/2015 09/18/2015
Note: see notes
ZON HOLD 09/14/2015 09/15/2015
Note: 1. The survey is incorrect. Tract 11 is not platted and is not part of Lot 11. Tract 11 must be removed from this residential permit application. 2. Site plan must be submitted on 8 1/2 x 11 or 8 1/2 x 14 paper and must include the following; width of Intracoastal Waterway Westerly Right of Way, dimensions of proposed structure and setbacks to closest point from structure to property line - include concrete door pads and A/C equipment with their dimensions; driveway material must be depicted - if paver driveway is to be installed, a Right of Way Utilization Agreement must be received and must be signed by all persons on deed to property. 3. Provide landscape plan on 8 1/2 x 11 or 8 1/2 x 14 paper. Remove Tract 11 from landscape plan. No landscape or tree removal is allowed as per #1 above.
URB COMPLETE 09/14/2015 09/16/2015

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 06/27/2017
REINSPECTION FEE ¤40.00 06/27/2017
REINSPECTION FEE ¤40.00 06/16/2017
REINSPECTION FEE ¤40.00 06/16/2017
REINSPECTION FEE ¤40.00 06/16/2017
REINSPECTION FEE ¤40.00 06/16/2017
REINSPECTION FEE ¤40.00 06/16/2017
REVISION ¤40.00 06/16/2017
REVISION ¤40.00 06/16/2017
REVISION ¤40.00 06/16/2017
REVISION ¤40.00 06/16/2017
REVISION ¤40.00 06/16/2017
SITE PLAN 20 ¤20.00 11/02/2015
SURCHARGE FS 533.721 ¤35.00 11/02/2015
SURCHARGE - FS 468.631 ¤35.00 11/02/2015
STORM WATER PERMIT FEES ¤80.00 11/02/2015
3% TRANS IMPACT FEE CREDIT (¤91.51) 11/02/2015
ADMIN FEE ¤20.00 11/02/2015
ELECTRIC FEE ¤364.80 11/02/2015
3% FIRE IMPACT FEE CREDIT (¤6.38) 11/02/2015
IMPACT FEE FIRE NONRESIDENTIAL ¤212.80 11/02/2015
IMPACT FEE PARKS ¤849.24 11/02/2015
IMPACT FEE SCHOOL ¤3,600.00 11/02/2015
IMPACT FEE TRANSPORTATION ¤3,050.24 11/02/2015
MECHANICAL FEE ¤364.80 11/02/2015
3% PARKS IMPACT FEE CREDIT (¤25.48) 11/02/2015
PLAN CHECK FEE ¤203.20 11/02/2015
PLUMBING FEE ¤364.80 11/02/2015
NEW RESIDENTIAL INSPECTIONS ¤1,016.00 11/02/2015
Fees Total Due: ¤0.00 Total Paid: ¤10,572.51